CDL Series Stainless Steel Vertical Multistage Centrifugal Water Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Performance of CDL Series Stainless Steel Vertical Multistage Pump

Flow Range:1-200m3/h

Head Range:11-200m

Power Range:0.37-110KW

Temperature:-20ºC-120ºC

Material:Stainless Steel 304,316

Work Pressure:<1.6mpa< span="">

2. Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Non self-priming type vertical multistage centrifugal pump, the motor is directly connected with the pump through shaft couplings, impeller guide vane is made of stamping stainless steel plate or precision casting stainless steel, smooth surface , hydraulic flow loss is small, and easily for cleaning, is very favorable for conveying pure medium. Pump inlet and outlet in a straight line(can be equipped with IEC or NEMA motor). 

3. Operating Conditions of CDL Series Stainless Steel Vertical Multistage Pump
Thin, clean, non inflammable and explosive liquid not containing solids or fiber. 
The liquid temperature: normal temperature type - 15 ºC to 70 ºC hot water type to + 120 ºC 
Environmental temperature: highest + 40 ºC 
Height: highest 1000m 

4. Motor Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Motor is fully enclosed, air-cooled type 2 pole standard motors. 
Protection grade: IP55 
Insulation grade: F 
Standard voltage: 1Ph 220-230/240V 
3Ph 200-220/346-380V 
3Ph 220-240/380-415V 
3Ph 380-415V 

5. Typical Applications of CDL Series Stainless Steel Vertical Multistage Pump
Water supply: water filtration and conveying, waterworks water supply, pipe pressurization, high-rise building pressurization. 
Industrial pressurization: process water system, cleaning system, high pressure flushing system, fire control system. 
Industrial liquid transportation: cooling and air conditioning system, the boiler feed water and condensation system, machine tool accessory, acid and alkali. 
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator. 
Irrigation: farm irrigation, sprinkler, drip.

 

6. FAQ

1>  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2> Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3>  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.


CDL Series Stainless Steel Vertical Multistage Centrifugal Water Pump

CDL Series Stainless Steel Vertical Multistage Centrifugal Water Pump





Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Variable flow pumps are variable pumps
To be exact, variable pump means variable displacement. Because if the displacement does not change
Q:Centrifugal pump flow, why can be adjusted through the outlet valve?
Reciprocating pump is a positive displacement pump, the volume change of flow is the unit of time, constant flow speed constant, can not rely on increased resistance to change the flow resistance increase is only leaked, only small changes in flow.
Q:The water tank of the fish tank does not air out and only has the water outlet
The air inlet pipe is connected with the oxygen burst, the entrance also pulled out, we can see that it is the design of a miter, the oblique incision back to the direction of the water flow speed, this outflow, negative pressure is formed in the oblique incision, the air can be sucked in. As shown.
Q:How to install, operate and maintain the pipeline booster pump?
Should be "People's Republic of China network security law" requirements, since June 1, 2017, the use of Internet services to carry out real name authentication account. In order to ensure your Baidu account can be used normally, please check the account number as soon as possible. Thank you for your understanding and support.How to install, operate and maintain the pipeline booster pump?Brother Yao s Gc76 2547 | browseRecommended for 2016-12-01 23:52:54 best answerThe installation of booster pump must be installed horizontally or vertically according to the installation method. The direction of flow shall be consistent with the arrow on the pump body, and installed as far away from the water level as possible. A valve shall be installed on the pump inlet line for ease of use and maintenance. When the impeller is the aspiration level below the pump on the pump shaft end or around the pump should be installed check valve, the outlet is connected with 13 links for water use, at first use to pump should be filled with water, and tighten the screw plug. The pipe connection should be tight, especially the water inlet pipe can not leak, otherwise it will reduce the pump head or not pumping water. The pump cavity is not water, not a long time running, so as not to damage the seal
Q:What should I pay attention to when buying a pump?
There are hundreds of water pump manufacturers in China, some of the family owned private enterprises are assembled in some areas, and the quality of the products is very good and bad, which makes it difficult to choose and buy. The main points are as follows:First, according to the required flow, lift, shaft power, efficiency, the necessary cavitation margin (or suction) and the use of conditions, the initial determination of the pump type, name, select the rated value and the required parameters of the same pump.
Q:How accurate is the metering pump?
The measuring accuracy of the stable metering pump is as follows:In a diaphragm metering pump, the reciprocating motion of the plunger is passed to the diaphragm through the hydraulic chamber between the plunger and the diaphragm. In order to maintain the normal movement of the diaphragm, the hydraulic chamber is required to keep the volume of the liquid in the space (usually using hydraulic oil) unchanged. In order to ensure that the volume of the formation of membrane movement is always equal to the stroke volume of the plunger pump, so as to maintain the stability of the flow, but in the actual operation of the pump, the plunger seal will inevitably cause leakage at the same time, there may be a gas into the hydraulic chamber
Q:What is the distance between the pump and the wall?
What do you mean by that? If your pump is parallel to the wall! Then, the wall of the pump near the wall is usually 500mm. This is an empirical data, considering the import pipe length, pump maintenance and motor heat dissipation and other aspects of the situation to determine. Dozens of pumps installed in our company are placed in this size! Hope to be of help to you.
Q:Fire hydrant pump button, under what circumstances do not need to install?
General high voltage system, when normal, use small pump steady pressure.Fire hydrant button lifting pump is one of the multiple pumping methods, and it is an important link of reliable operation of the system.
Q:What are the application areas of pumps?
Performance range from the pump to see giant pump flow up to hundreds of thousands of cubic meters per hour, while the micro pump flow per hour in a few milliliters; pump from atmospheric pressure up to 19.61Mpa (200kgf/cm2); the lowest temperature of the liquid is transported up to -200 DEG C, up to 800 DEG C. Pumps carry a wide variety of fluids, such as water (clean water, sewage, etc.), oils, acid and alkaline solutions, suspensions, and liquid metals.In the chemical and oil sector production, raw materials, semi-finished products and finished products are mostly liquid, and semi-finished and finished products to raw materials, need to go through a complex process, to pump and provide transportation of liquid chemical reaction of the pressure and flow in the process, in addition, the device also used in many pumps to adjust the temperature.In agricultural production, the pump is the main irrigation and drainage machinery. Rural areas in our country are vast and vast, and a large number of pumps are needed every year in rural areas. Generally speaking, agricultural pumps account for more than half of the total output of pumps.Pumps are also the most widely used equipment in the mining and metallurgical industries. The mine needs pumping and drainage. In the process of ore dressing, smelting and rolling, the pump needs water to supply water first.
Q:Is the sewage pump the same as the mud pump?
Two of the main performance parameters of mud displacement and pressure, displacement from a number of liters per minute, with the diameter and the drilling fluid requirements from the hole on the back end of the speed, the larger aperture, the greater the displacement. The upstream return speed of the washing fluid is required to remove the cuttings and rock powder from the drill in a timely manner from the bottom of the hole and reliably carry it to the surface. Through drilling and extraction, mud can be obtained at the bottom.Sewage pump is mainly used for industrial wastewater treatment, sewage treatment, environmental protection has played a big role. Among them, the sewage pump is also a sewage pump with cutting wheel, such sewage pump can be chopped dirt, and then extract the sewage clean.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range