CDL and CDLF(T) Series Stainless Steel Vertical Multistage Pumps

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
400 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Performance of CDL Series Stainless Steel Vertical Multistage Pump

Flow Range:1-200m3/h

Head Range:11-200m

Power Range:0.37-110KW

Temperature:-20ºC-120ºC

Material:Stainless Steel 304,316

Work Pressure:<1.6mpa< span="">

2. Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Non self-priming type vertical multistage centrifugal pump, the motor is directly connected with the pump through shaft couplings, impeller guide vane is made of stamping stainless steel plate or precision casting stainless steel, smooth surface , hydraulic flow loss is small, and easily for cleaning, is very favorable for conveying pure medium. Pump inlet and outlet in a straight line(can be equipped with IEC or NEMA motor). 

3. Operating Conditions of CDL Series Stainless Steel Vertical Multistage Pump
Thin, clean, non inflammable and explosive liquid not containing solids or fiber. 
The liquid temperature: normal temperature type - 15 ºC to 70 ºC hot water type to + 120 ºC 
Environmental temperature: highest + 40 ºC 
Height: highest 1000m 

4. Motor Introduction of CDL Series Stainless Steel Vertical Multistage Pump
Motor is fully enclosed, air-cooled type 2 pole standard motors. 
Protection grade: IP55 
Insulation grade: F 
Standard voltage: 1Ph 220-230/240V 
3Ph 200-220/346-380V 
3Ph 220-240/380-415V 
3Ph 380-415V 

5. Typical Applications of CDL Series Stainless Steel Vertical Multistage Pump
Water supply: water filtration and conveying, waterworks water supply, pipe pressurization, high-rise building pressurization. 
Industrial pressurization: process water system, cleaning system, high pressure flushing system, fire control system. 
Industrial liquid transportation: cooling and air conditioning system, the boiler feed water and condensation system, machine tool accessory, acid and alkali. 
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator. 
Irrigation: farm irrigation, sprinkler, drip.

 

6. FAQ

1>  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2> Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3>  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

 

CDL and CDLF(T) Series Stainless Steel Vertical Multistage Pumps

CDL and CDLF(T) Series Stainless Steel Vertical Multistage Pumps


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Fire pump control cabinet There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, and two outdoor pumps
You said the three line refers to the control room, the control cabinet, the main pump directly start the straight line of water pump. Each pump should be equipped with single straight line Kai, reported that the cabinet Jinglian dynamic multi line linkage control board has three buttons corresponding to a remote spray pump, fire hydrant pump, pump start outdoor fire hydrant. This requires three straight lines, from the cabinet to the three pump control cabinet, which is the 9 line you call. The water pump control cabinet is provided with a terminal for supplying a remote pump. By looking at the wiring diagram of the water pump control box, you can find the technical personnel of the control cabinet manufacturer if you can't find them.
Q:What is the "variable" of a variable pump?
These two don't mean the same thing? That is, the pump outlet can be changed
Q:Fire pump and shower pump flow head selection, high resolution.
Selection of flow head of fire pump and spray pump:1, the volume is greater than 5000 is less than 10000, the minimum water consumption of indoor fire hydrant is 10L/s
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe
Q:What is the difference between swashplate pump and crankshaft pump?
Swash plate pump motor is driven as a coaxial swash plate drive plunger pump crankshaft work produces high pressure water in general simply and motor rotor to form a 90 degree angle of the motor through the crankcase to drive the piston to work in general the crankshaft speed is relatively high in the 2800 turn left and right to use the cost of the swash plate speed the use of less than 300 kg pressure in about 1400 when the crankshaft is relatively high but in more than more than 300 kilograms of crankshaft pump highlights the advantage of his adopted lookout!!!
Q:Variable flow pumps are variable pumps
Yes. The variable pump is designed to change the flow rate
Q:How many concrete pump tube diameter
Different pipe diameter is different, most of the 125, there are 150. Now we have the smallest pump on the market, with a pipe diameter of 100.
Q:How many pumps does the 80cm tank use?
Filter pump to select the water per hour can be filtered more than 3 times, I personally feel that this is almost enough. Of course, the more times the better, but also consider that if the pump is too large, the water inside the tank will be too large.128X3=384LThat is, the flow must be more than 384L/H of the water pump.You can buy a bigger pump, because the pump for a long time there will be some attenuation and domestic things in general to sign data, so it should be based on your actual situation to buy. Taobao on this category is about 20~40 yuan.
Q:Difference between pump and compressor
A pump is a machine that transports liquids or pumps liquids. It transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. The pump is mainly used to transport water, oil, acid and alkali liquid, emulsion, suspension emulsion and liquid metal, and also can transport liquid, gas mixture and liquid containing suspended solid. Pump can usually be divided into three types of displacement pumps, power pumps and other types of pumps according to the principle of operation. In addition to classification according to the working principle, it can be classified and named according to other methods. For example, according to the driving method can be divided into the electric pump and the turbine pump; according to the structure can be divided into single-stage pump and multistage pump; use can be divided into the boiler feed pump and the metering pump; according to the nature of transmission fluid can be divided into water pump, oil pump and mud pump etc.. In accordance with the non axial structure, can be divided into linear pumps and traditional pumps.
Q:What is the difference between centrifugal pump and positive displacement pump?
Positive displacement pump is the volume pump, this type of pump is to rely on changes in volume to compress fluid work, including: diaphragm pumps, gear pumps, screw pumps, etc.;

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range