Cast Iron Soft Sealing Flanged Gate Valve

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
200 PCS
Supply Capability:
10000 PCS/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

BS5163 NRS Gate Valve 
1. Manufacturer 
2. TUV, ISO, SGS certified 
3. WRAS Approved 
4. Resilient seat EPDM seat

BS5163 NRS Gate Valve  

Specification:

1. Size: 1-1/2"-24" (DN40-DN600)

2. Design Standard: BS5150, BS5163, AWWA C509/C515, DIN3202 F4/F5, MSS SP-70.

3. End Flange Connection: ANSI B 16.1, BS EN 1092(PN10, PN16), DIN 2501(PN10, PN16), BS 10 Table E

4. Disc: Grey iron, Ductile iron, with or without EPDM

5. Seat: Stainless steel, Brass/Bronze etc, Soft seat or seal: EPDM, NBR

6. Testing: API 598, ISO 5208

7. Options: Lever, Gearbox operate, Electric actuator, Pneumatic operator, Opening indicator, With limit switch, Others.

8. Type: Non rising stem, Rising stem

9. Finishing: Epoxy coating, Painting etc

10. Usage: Water supply and drainage, Electric power, Petrochemical, Metallurgical, Firefighting / Fire fighting, or other industries.

Specifications

valves 
1)DIN3352/BS5163/API600 
2)Pressure:PN10/16 
3)Dimension:2'-36'

Technical Specifications: 

Design: EN593 
Face to face: EN558-1

Flange drilling: EN1092 
Upper flange connection: ISO 5211

  • Gate Valves, Check Valves, Butterfly Valves, Strainers, Fire Hydrants and Full ranges of Pipeline products & accessories

  • DIN / BS / EN / API / ANSI / AWWA Standards available with different Material & Specs

  • Competitive Price, Reliable Quality & On-time Delivery 

  • Reliable Quality Assured by ISO 9001 2008

  • Competitive Price by Strict Cost Control

  • On-Time Delivery by All- Process Production Plan and Control

  • A group of highly experienced technical engineers is right here waiting for any of your requests.

  • Professional softwares are used for design and test.

  • We are able to use most of the world-wide engineering softwares, including AUTO Cad, Pro Engineer, Solid Works and etc.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What does gate valve Z41H-40 mean?
Z - that means gate valve (the initial letter of Zha)4---- is the connection form, which means flange connection1---- form of structure, which means Plain Bar wedge type rigid single gate valveH---- sealing surface overlaying ferrous carbide (initial letter of alloy steel He)40---- nominal pressure is 40 kg, or 4.0MPa, that is, PN10 at 250 degrees Celsius, the maximum working pressure is 40 kgThe material is cast carbon steel
Q:What do gates, Z15T-10, Z15W-16T, Z45T/W-10, Z41T-10 mean?
1, gate valve type code named Z;2, gate valve drive mode code by letters, common 2- electric hydraulic, 9- electric, 6- pneumatic, 5- bevel gear drive, 3- turbo worm; manual do not need to write out;3, gate valve connection form code with letters to indicate, 1- internal thread, 2- external thread, 4- flange type, 6- welding, 7- pairs clamp type, 9- clamp, 0- card sleeve;4, the valve structure of code, 0- flexible wedge, 1- rod single wedge gate valve, 2- rising stem wedge gate valve, 3- parallel single gate valve, 4- parallel double gate valve, 5- dark pole single wedge gate valve, 6- dark bar wedge gate valve
Q:What does gate z41t-10 150 mean?
According to JB/T308-2004 "valve type programming method"Z gate valve4 flange connection1 Ming wedge single gateT sealing cover material is copper alloy10 nominal pressure PN10PN16 below no marked valve body code, body material is gray cast iron150 nominal size DN150
Q:What type of flange does it fit with the gate valve?
According to the welding plate flange, flange material selection of piping material.
Q:Why can't the pressure measuring point be set at the two ends of the gate valve when measuring the resistance loss of the gate valve?
the valve before the pressure measuring point, distance of valve straight pipe length is 5 times the diameter of the valve after the pressure valve, the distance is 10 times the diameter of straight pipe length.
Q:What are the working principles of the electric gate valve?
Ordinary type electric valve should be equipped with the control box, the motor is the true story and the inversion, and in general to a trip signal signal is normally open and normally closed, closed in place are normally open and normally closed two points according to their own needs wiring, three lines and then open and close control of the line of control there are also 4 lines to control some manufacturers, as well as the valve position, some three lines connected with the potentiometer, some installed valve position transmitter is connected with two lines, and over torque protection fault signal.
Q:What does gate valve Z44T-10-200 code mean?
The meaning of the model is standard, the landlord himself to check the JB/T308 standard, Baidu library some, and is free to download:JB/T 308-2004 valve type method of preparation clear EditionHttp://wenku.baidu.com/view/5f798850ad02de80d4d84036.htmlZ = gate valve4 = connection: flange4 = structure form: double gateT = sealing surface material: Copper10 = nominal pressure: 1.0MPa, followed by no letters indicate body material: Cast Iron200 = nominal path: DN200
Q:What does the gate valve 150# mean?
I think PSI is equal to 150#The sign behind is "PSI"You Baidu "ANSI standard pressure, pound scale and nominal pressure relations table" will knowI'm new, too, I understand
Q:Analysis of the advantages of elastic seat sealing gate valve?
Most of the valve is forced seal, that is, when the valve closed, to rely on external force to force the gate to the seat, in order to ensure the sealing surface sealing.When opening the gate valve, when the gate lift height is equal to 1:1 times of the gate diameter, the passage of the fluid is completely unblocked, but at run time, this position is unable to monitor. In actual use, the top of the stem is used as a sign, i.e., the open position, as its fully open position. Temperature changes appear to consider locking phenomenon, usually open to the vertex position, and then rewind 1/2-1 circle, as a fully open valve position. Therefore, the opening position of the gate valve is determined by the position of the gate (i.e. the stroke). The sealing surface is easy to wear and tear, affecting the service life. When opening and closing, gate and valve seat two sealing surface friction, sliding, to medium pressure under the action of easy to produce abrasions, wear, affect sealing performance, shorten service life.
Q:What is the difference between the cut-off valve and gate valve, the general will use the cut-off valve instead of gate valve
Yes. Globe valves and gate valves are indeed common in certain piping and operating conditions.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range