Cable with Transducer Cable with Transducer Cable with Transducer

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Produced with the reference to standards of GB/T12706.1-2002 "rated voltage 1 KV (Um = 1.2kv) to 35 kv (Um = 40.5kv) crowded pack power cable insulation and Annex 1: rated voltage 1 kv (Um = 1.2kv) and 3 kv ( Um = 3.6kv) cable " It applies to all kinds of cable connecting of equipment with transducer such as frequency power, and convertible motor. With the three-phase symmetrical structure, the cable can increase the capacity of resisting electromagnetic interference. The cable has a variety of shielding structures. Vertical package with aluminum-plastic composites can effectively shield cable itself from outside electromagnetic interference, thereby enhancing the efficiency of equipment with transducer. The shielding structures of Copper belt and brass wires shield the electromagnetic wave produced by the cable to prevent leak, protecting other equipment from interference and the environment from the electromagnetic pollution.


main speciality

◆ Max. permissible continuous temperature: PVC: 70℃; XLPE: 90℃.
◆ Max. short-circuit temperature of the conductor shall not exceed: PVC : 160℃; XLPE:250℃.
◆ The installation temperature should not below 0℃ .
◆  The bending radius of cables are recommend as follows: the soft  conductor is not less than 10 times the diameter of cables; others is  not less than 15 times the diameter of cables.


type

name

non armoured

Steel tape armoured

BPVPV

 -----

PVC insulated copper wire braid shield cable with transducer

ZR-BPVPV

----

PVC insulated copper wire braid shield fire-proof cable with transducer

ZR-DL-BPVPV

----

PVC insulated copper wire braid shield low smoke and low halide content fire-proof cable with transducer

BPVPVP3

----

PVC insulated copper wire braid shield AL-plastic compound band shield cable with transducer

ZR- BPVPVP3

----

PVC insulated copper wire braid shield AL-plastic compound band shield fire-proof cable with transducer

ZR- DL-BPVPVP3

----

PVC  insulated copper wire braid AL-plastic compound band shield low smoke  and low halide content fire-proof cable with transducer

BPVP1VP2

BPVP1VP2-22

PVC insulated copper wire circle copper tape shield cable with transducer

ZR-BPVP1VP2

ZR- BPVP1VP2-22

PVC insulated copper wire circle copper tape shield flame-resistant cable with transducer

ZR-DL- BPVP1VP2

ZR-DL-BPVP1VP2-22

PVC insulated copper wire circle copper tape shield low smoke and low halide content flame-resistant cable with transducer

BPVP1VP3

BPVP1VP3-22

PVC insulated copper wire circle AL-plastic complex tape shield cable with transducer

ZR- BPVP1VP3

ZR- BPVP1VP3-22

PVC insulated copper wire circle AL-plastic complex tape shield flame-resistant cable with transducer

ZR-DL- BPVP1VP3

ZR-DL- BPVP1VP3-22

PVC  insulated copper wire circle AL-plastic complex tape shield low smoke  and low halide content flame-resistant cable with transducer

BPVP2V

BPVP2V22

PVC insulated copper tape shield cable with transducer

ZR- BPVP2V

ZR- BPVP2V22

PVC insulated copper tape shield flame-resistant cable with transducer

ZR-DL- BPVP2V

ZR-DL- BPVP2V22

PVC insulated copper tape shield low smoke and low halide content flame-resistant cable with transducer

BPYJPV

-----

XLPE insulated copper wire braid shield cable with transducer

ZR-BPYJPV

-----

XLPE insulated copper wire braid shield flame-resistant cable with transducer

ZR-DL-BPYJPE

-----

XLPE insulated copper wire braid shield low smoke and low halide content flame-resistant cable with transducer

BPYJPVP3

 -----

XLPE insulated copper wire braid AL-plastic complex tape shield cable with transducer

ZR- BPYJPVP3

 -----

XLPE insulated copper wire braid AL-plastic complex tape shield flame-resistant cable with transducer

ZR-WL-BPYJPVP3

 -----

XLPE  insulated copper wire braid AL-plastic complex tape shield low smoke  and low halide content flame-resistant cable with transducer

BPYJP1VP2

BPYJP1VP2-22

XLPE insulated copper wire circle copper tape shield cable with transducer

ZR-BPYJP1VP2

ZR-BPYJP1VP2-22

XLPE insulated copper wire circle copper tape shield flame-resistant cable with transducer

ZR-WL-BPYJP1VP2

ZR-WL- BPYJP1VP2-22

XLPE insulated copper wire circle copper tape shield low smoke and low halide content flame-resistant cable with transducer

BPYJP1VP3

BPYJP1VP3-22

XLPE insulated copper wire circle AL-plastic complex tape shield cable with transducer

ZR-BPYJP1VP3

ZR- BPYJP1VP3-22

XLPE insulated copper wire circle AL-plastic complex tape shield flame-resistant cable with transducer

ZR-WL-BPYJP1EP3

ZR-WL- BPYJP1VP3-22

XLPE insulated copper wire circle AL-plastic complex tape shield low smoke and low halide flame-resistant cable with transducer

BPYJP2V

BPYJP2V22

XLPE insulated copper tape shield cable with transducer

ZR-BPYJP2V

ZR- BPYJP2V22

XPLE insulated copper tape shield flame-resistant cable with transducer

ZR-WL-BPYJP2E

ZR-WL- BPYJP2E22

XLPE insulated copper tape shiled low smoke and low halide flame-resistant cable with transducer


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:150,120,95,50,25,10,4 * 1.5,2 * 1.5 how much cable to use the heat shrink tube
Due to the circumstances of the question .. at any time questioned us
Q:1.2 meters below the road can use pvc tube wear armor cable?
The former bv4 square copper wire is a single strand of hard copper wire, the latter BV4 square copper wire is multi-strand soft copper wire. Core (coredwire), with steel sheath for the outer tube filled with iron alloy powder to do core material, cross-section for the circular or rectangular line body. Also known as cored wire. It is used as a steel-making furnace outside the refining of the feed method to add refining agent and alloying agent. Can be directly added to the deep steel, the molten steel for deoxidation, desulfurization, degassing and non-metallic inclusions denatured treatment, to eliminate the aluminum deoxidized steel in the continuous casting steel | iron when the nozzle plugging the problem. As the deep addition of alloying elements in the molten steel, so the alloying element recovery rate is high and stable, the steel components can be fine-tuned to the best range. The reproducibility of the results is good.
Q:Brief description of the difference between cable and cable.
Network cable is to take the digital signal, CATV cable is to take the analog signal, how can interfere with each other, do not understand do not see this stare blindly understand the beads. It was all right to be wrapped around with an electrical tape.
Q:Choose the configuration of good or bad computer graphics card memory processor, etc., how to choose a different manufacturers
Calculation method: the amount of engineering calculation formula: L = (pipe length calculation + wire reserved length) × with the number of cross-section wire. Note: plastic pipe should not be flattened, cracks, no debris in the tube, cut the mouth should be flat, the nozzle should be shaved plastic wire pipe connection using glue bonding, plastic pipe bonding must be tightly tight, and in the pipeline plug on the plastic pipe plug, to prevent the paddle, plug tube concrete floor, wall and brick structure of the various switches, socket bottom box , The lamp junction box and the pipe connection must be connected with the wiring, is strictly prohibited plastic pipe directly into the junction box dark in the concrete junction box requirements with wet cement paper or plastic foam filled with internal, not allowed to use The cement paper packs its outside. Embedded in the floor, the shear wall of the plastic pipe, the junction box should be fixed firmly to prevent the shift
Q:The UV lamp is fitted with ozone and no ozone difference
Man, your weak tube is not quite long? If the length of the pipeline is very long, you need to wear the wire, unless you have no wire can be threading method. Your length of the pipeline is very long, in the tube when the tube has been added? There is no wire box to make up.
Q:Why my home analog TV connected to the digital TV set-top box after the screen is black and white
Our teacher wants us to do the thermometer, but I do not know what to do. The What materials should I use? The Whether my straw is now pressed and deformed, and adjust the water level, so that the water level is slightly higher than the bottle, with oil pen in the straw
Q:What recycled rubber is suitable for the production of wire and cable?
The power industry mainly includes electricity industry and power plants and other power cables industry is the power industry to do the cable and cable should belong to the power industry but does not belong to the system within the power system only includes the State Grid China Southern Power Grid five nuclear power plants and other large state-owned enterprises
Q:What kind of material should be selected for the fixing bracket of the cable trunking
2.5 square copper (green, with the threading tube) theory will be able to withstand about 20A current, consider the pipe, temperature and other factors, so according to the actual can withstand about 3 kilowatts of power. In fact the 2.5MM2 copper wire is generally open 16A can withstand about 3.4 kilowatts of power.
Q:How to determine whether the square of the cable is standard
laying the dark tube should be used when the steel pipe or flame retardant PVC pipe
Q:Can 110kv and 10kv cables co-share with trenches? What is the relevant specification?
According to Article 22.7.1 of the Electrical Design Code for Civil Buildings JGJ16-. the transmission lines and the electronic information system transmission lines shall be laid separately and shall be shielded when they are close to the laying of them in parallel by the construction conditions. High-voltage cable under normal circumstances is not allowed and weak cable with the ditch laying. If the relevant control cable does need to be with the high-voltage cable ditch, should be laid on both sides of the laying and keep the distance, but also pay attention to control cable shielding measures.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range