BZ Series Self-Priming Centrifugal Water Pumps

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
1000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Production Introduction for ZB Series Self-Priming Centrifugal Water Pumps: 
WZB self-priming pump is divided into single phase and three-phase asynchronous types with built-in protection device. The pump is divided into centrifugal impeller and worm casing structures with self-priming function. Single-face mechanic sealing is mounted between pump and motor."0" shaped oil-proof rubber seating ring is used at each stationary port as static sealing.

2. Application for ZB Series Self-Priming Centrifugal Water Pumps
This series pump is a new type of ideal economical pump, widely used in pumping water, increasing water pressure, garden irrigation, water supply for vegetable green houses, industrial mining enterprises and aquatic breeding fields etc.

3. Work Conditions for ZB Series Self-Priming Centrifugal Water Pumps
The pump can work properly and continuously under following operational conditions:
1.Medium is not corrosive.Sand contents should be max.0.10% by volume and granular size should be max.0.20mm.
2.Medium temperature shouldn’t be over 40°C and PH should be 6.5-8.5.
3.Power frequency should be 50Hz,single phase voltage 220V, three-phase voltage 380V,and voltage fluctuation should be 0.9-1.1 times than the rated.

4. FAQ for ZB Series Self-Priming Centrifugal Water Pumps

1. Are CNBM pumps available in DIY stores?

Yes, currently, we’re available for DIY stores all over the world.

2. Where do I have to send pumps for service?

You must send them to the CNBM PUMP Service Point or, after contacting Customer Care, to the CNBM PUMP service center in China.

3. Are your pumps acid-proofed?

To choose the right pumps for chemical applications, we do need further details on hydraulic operations as well as on the type, concentration and temperature of the liquid.

BZ Series Self-Priming Centrifugal Water Pumps

BZ Series Self-Priming Centrifugal Water Pumps


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
For example: water storage is relatively small, it needs to reduce the temperature of the heat exchanger. If the tank is relatively large, it does not need cooling water circulation pump again when the temperature is very low, there is no need to heat exchanger. So you need to ask how much water this is not OK.In a soda separator problem:
Q:What is the difference between centrifugal pump and rotary vane pump?
This is a classification problem.Rotary is classified by movement, vane pumps are rotary, volumetric pumps are mostly rotary, piston pumps, etc., is reciprocating.
Q:Concrete pump 125 pipe wall thickness
Concrete pump diameter 125mm, pipe wall thickness is generally 4mm, also have 4.25mm, 4.5mm, 4.75mm, need to be in accordance with the rules of transport.
Q:Is the diaphragm pump and the drain pump one?
Generally composed of actuators and valves.Pneumatic diaphragm pump, which has four kinds of materials: plastic, aluminum alloy, cast iron, stainless steel. The electric diaphragm pump has four kinds of materials: plastic, aluminum alloy, cast iron and stainless steel. Diaphragm pump diaphragm according to different liquid media, respectively, NBR, chloroprene rubber, fluorine rubber, PTFE, poly 46 ethylene to meet the needs. Placed in a variety of special occasions, for pumping various media.
Q:What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
SK vacuum pump is a single-stage water ring vacuum pump, vacuum pump and motor separation, coupled with couplings, vacuum relatively low.
Q:Metering pumps related matters
2) change the metering pump diaphragmTrouble is often encountered when the old diaphragm is removed. Provide some additional advice on how to remove the old diaphragm.After in the pump head loose, remove the pump head before the stroke length adjustment to the 10% position. To ensure that the electromagnetic axis has sufficient pressure to maintain its connection firmly, so that you can unscrew the diaphragm.The pull end torque from the Jack out of the screw. Seize the liquid counter clockwise rotation. There is a slight resistance that can unscrew the diaphragm.Chemical 3 measurement may end in fluid crystallization, resulting in a one-way valve ball and seat valve does not work.In the end inhalation metering pump may have a gas leak. Hydraulic end suction side connector may lack O ring or suction valve connection loose.3) flow monitoring and measurement of a high viscosity medium, in the process of liquid delivery received a flow failure signal, how can we solve this problem?Move the hydraulic end by loosening the 4 pump head screws. Rotating stroke length to 10%, and seize the hydraulic end, and then slide out of the screw hole, then the screws do not touch them, but still control the back and diaphragm. Then rotate the component counter clockwise, with a slight resistance, and the diaphragm will loosen from the electromagnetic axis. If the diaphragm is not loose, use some grease on the contact surfaces of the diaphragm and the electromagnetic shaft. After a few minutes, gently tap the diaphragm with a small plastic hammer. Then proceed again in accordance with the above description.
Q:How many millimeters is the diameter of the water outlet of the four inch pump?
This question is of no practical significance. The user does not care about this figure. The concern should be the nominal diameter, which is fitted with flanges and pipes. Moreover, the pump shell is cast iron, the inside diameter is not processed, and there is no matching parts, there is only one manufacturing size.
Q:What should be used to pay attention to the use of mechanical pumps?
Overall: large pump should first do a good job of the foundation, to find a good whole, fixed, and motor, pump should be added good oil, the first test of the motor, and then conjoined test
Q:What are the starting and stopping procedures for centrifugal pumps?
The use of centrifugal pump can be divided into three steps, namely, start, run, stop.Start: you should do the following preparation before starting:(1) check the water pump equipment in good condition.(2) the bearings are filled with oil, the oil level is normal, and the oil quality is qualified(3) all the inlet valves of the centrifugal pump are opened.(4) pump water injection or vacuum pump diversion (except for flow), open the vent valve exhaust.(5) check the leakage of shaft seal. It is advisable to fill the seal with a little drop of water.(6) the motor rotates in the right direction.
Q:What are the main performance parameters of the pump?
The amount of liquid supplied by a pump in unit time. Volume flow Q, unit m3 / s. There is mass flow G, unit is kg / s.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range