Bubble Laminated With Metalized Film

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or L/C
Min Order Qty:
40HQ m²
Supply Capability:
20 tons/week m²/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Specification of Bubble Laminated with Metalized Film

STRUCTURE

MPET /BUBBLE/MPET

THICKNESS

2.8mm

BUBBLE SIZE

4mm x 10mm

WEIGHT

200GSM

REFLECTIVITY

96-97%

THERMAL CONDUCTIVITY

0.034W/MO

WATER VAPOUR TRANSMITTANCE

0.013g/m2 KPA

WIDTH

1.2m (W) X 40M (L)

 
2. Application of Bubble Laminated with Metalized Film

(1). Building reflective heat, cold and hot water pipe insulation;

(2). refrigerator partition, central air conditioning, regrigerator and household applliancs insulation;

(3). Insulation, sold-absorbing, noise reduction and moisture-prooof insulation in the care, train, refrigerator car, laboratory and other industries;

(4). Special product packaging and refrigerated packing and so on.

3. Packaing and delivery of Bubble Laminated with Metalized Film

Depends on the clients' requirements and the production conditions.

 double layer bubble

 pp bags packaging

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Can you put fiberglass insulation on the under side of roof tiles in the loft in the house?
You should not be able to see your roof tiles from inside your house. So no, it can not be done. You can attach insulation to the rafters if that is what you meant.
Q:How does insulation work to prevent heat transfer in the walls and roof of a house?
All versions of insulation are largely air that is kept from moving - air is a good insulator if convection - movement of heated or cooled air due to changes of density - is prevented. This assumes that a vapor barrier and caulking prevent actual air movement through the wall when a wind is blowing. Some insulators are also poor conductors of heat so the connection between inside and outside that might occur is broken. As it happens, glass used in fiberglass and minerals used in rock wool are actually pretty good conductors of heat in solid form but as fine particles and flakes they don't conduct well from one strand/piece to the next.
Q:Want to use fiberglass insulation in big closets under home roof?
If there is no existing insulation you need a vapor barrier 1st or you need "faced" fiberglass, the one with either plastic or brown paper on it. I put it as thick as you can afford.
Q:Foam insulation spray roofing, Greenest way to build?
First, "green" building is not technically defined as far as the construction industry is concerned. i.e. anyone can call their products "green" until the parameters are set up to strickly define what is "green" and what is not. To date, it's been more of a marketing strategy than anything. (Unless this has changed in recent months) I'm glad to hear New Orleans is taking the right path in rebuilding the place! Hope to get back down there soon.
Q:Can I put insulation on top of my roof and then roof over it with metal roofing?
The only downside I see is your miscalculation about the length of the screws need. Lets see, 2 inches of insulation, 3/4 inches of furring, leaves you with a solid 1/4 inch of bite, and we all know that the first 1/4 inch of the screw is meant for piercing, not holding. So plan on 4 inch screws, because you still need to penetrate the old roof and bite the structure. Don't forget to plan your drip edge which now will have 2+ inches of roof thickness to carry the rain water over into your gutter.
Q:the roof of my mouth hurts bad.i worked all day with sawdust and insulation yesterday.is this the problem.?
No it may not be like any type of respiratory disease ,normally this type of soe type of allergy ,if you have any doubt you can consult a doctor but are you suffering from asthma before or any person of your family belongs to this category.
Q:Best insulation for Pex tubing 3/4 pipe in the roof? HELP!!!?
Check into heat tape tied to pipe, with insulation wrapped around that. turns on when freezing temperatures. insulation by itself, will not stop it from freezing if left for long periods without water moving through it. .
Q:If a roofing contractor offers an insulation material with an R value of 2.5 instead of 3?
You don't want that. If he offers 3.5 instead of the required 3, that is a different story. Otherwise he should give you more material thickness to provide an equivalent R of 3. Yes, the difference can be substantial and I wouldn't forward it to the client. The smaller the R value of the entire roof sandwich the larger the difference it makes. Like the change from 5 mpg to 4 mpg is a 25% worsening in fuel economy, but a change from 100 mpg to 99 mpg is 1%. It will mess up the heating/cooling of the building and the mechanical systems might be inadequate. They could save money on the roof and complain how the building is too hot/too cold or the mechanical systems never shut off and their energy bills are too high.
Q:where can i find and compare prices on roofing and insulation materials?
You could call ABC supply or Norandex Reynolds, they are the biggest distributors I know of. They may have some resources for you.
Q:My upstairs ceilings are not insulated and on the other side of the 2x6 rafters is the roof.?
Suggestion: install the insulation with the foam channels but leave the center section (roof ridge area) open from end to end. At each end you can install a static vent or an active one. Depending on the amount of space you have you may be able to install a power vent.If you can send me a diagram with measurements I can give you a more definitive answer.
We are a well-known enterprise specializing in the production and sales of high-grade meltalized film, foil film, foil foam and other composite product. Since the establishment of our company, we have been devoted to setting up a good reputation in the world.

1. Manufacturer Overview

Location Hangzhou, China
Year Established 2006
Annual Output Value Above US$ 18 Million
Main Markets 10.00% Mid East
15.00% Northern Europe
10.00% North America
22.00% Eastern Asia
7.00% Africa
7.00% Eastern Europe
18.00% Southeast Asia
4.00% Oceania
4.00% Western Europe
3.00% Southern Europe
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shanghai
Export Percentage 30% - 50%
No.of Employees in Trade Department 20-35 People
Language Spoken: English; Chinese
b)Factory Information  
Factory Size: Above 6000.00 square meters
No. of Production Lines Above 8
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range Low; Average