Belt Lsolation Transformer UPS 1-10KVA

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
20 Pieces pc
Supply Capability:
5000 Pieces per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

Key Features

Large Blue Back Light LCD for Detailed Real-Time UPS Status Display

Microprocessor Control Guarantees High Reliability

Comprehensive Self-Protection Design

Audible Alarm Mute

Cold Start Function

Auto Self-Testing System while Turning On UPS

Wide input Voltage Range

Zero trantfer time

Smart RS-232 interfact , SNMP and USB is option

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Power and lighting transformers, lighting quality will be affected much?
First look at this light. 24V100W, this specification is common in the headlights of large trucks, filled with inert gas, known as the small sun. Its power comes from a generator or battery, and is lit by alternating current or direct current.
Q:Who knows how big transformers and lines the 36V transformer uses in lighting?
Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
Q:Our power lines and lighting lines are connected to the same transformer. Is there any effect?
It is not easy to control, the power and lighting and electricity; if the transformer capacity is small, and relatively large power equipment start frequently, voltage stability will be poor, the lamp brightness will fluctuate dramatically, have effect on visual acuity. But as long as the design is reasonable, it has little effect.
Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
So, safety regulations: lighting transformer must double winding type safety isolating transformer, prohibited the use of autotransformer.
Q:1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
You must know the quantity and power of the lamp to determine the transformer
Q:Why is elevator lighting transformer installed?
3 a power outlet shall be provided at the bottom pit.4 the cables and wires laid in the hoistway shall be flame retardant and damp resistant, and shall be protected by a nonflammable wire, conduit, or wire slot, with no use of wires, conduits, or wire slots made of combustible material.5 an elevator attached to a building whose wiring, materials and methods and electrical components used shall take into account the effects of climatic conditions and shall take waterproof measures.Lighting transformers in order to obtain 36V voltage
Q:Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
220V500W more power saving:Reasons: 1, high voltage, small current, line loss is small; 2, reduce the transformer and other intermediate links, each link has a loss.
Q:What transformer can be used in a safety voltage lighting transformer?
220V/36V or 24V isolation transformer. Double winding, high and low voltage coils, not connected.
Q:How many A leakage protection switches are used in 5000VA lighting transformers?
According to the working principle of the protector, it can be divided into three kinds: voltage type, current type and pulse type. The voltage protection device is connected to the transformer neutral point and the ground, when the electric shock when the neutral point voltage offset to the real estate, in order to make the action to protect the power off, but because it is the protection of the transformer low voltage network, cannot be classified protection, so the power range is large, frequent moves, so has been eliminated. The pulse current protector is a sudden change in the phase and amplitude of the three-phase unbalanced leakage current when an electric shock occurs, which is used as an action signal, but also a dead time. The current type current leakage protector is widely used, so the protector of current type is mainly introduced below.
Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
If there is no painting can be used with a diode symbol file (measuring probe connected to the capacitor to hear a sound if the table does not ring at the table and then the general display is 1, then the pen on the emergence of the phenomenon that the capacitance is still good. If one table has been ringing that received the capacitor capacitor breakdown is broken)
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications.if you have interesting, please kindly contact us! We will provide our good quality products and best services to you!

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2006
Annual Output Value US$10 Million - US$50 Million
Main Markets 9.09% North America
9.09% South America
9.09% Eastern Europe
9.09% Southeast Asia
9.09% Africa
9.09% Mid East
9.09% Eastern Asia
9.09% Western Europe
9.09% Southern Europe
9.09% South Asia
Company Certifications UPS CE UG/UX 1K; UPS CE (UG/UX) 2/3K; standards organisation of nigeria soncap; Soncap UX6K

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen China
Export Percentage 61% - 70%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 10,000-30,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average