• battery with 10 years life design 12v 65Ah System 1
  • battery with 10 years life design 12v 65Ah System 2
battery with 10 years life design 12v 65Ah

battery with 10 years life design 12v 65Ah

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 unit
Supply Capability:
5000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Quick Details

  • Place of Origin:                     Jiangsu, China (Mainland)

  • Model Number:                     LCPC65-12

  • Usage:                     UPS

  • Voltage:                     12v

  • Sealed Type:                     Sealed

  • Maintenance Type:                     Free

  • Size:                     350*166*174(mm)

  • Weight:                     22±0.5KG

  • Nominal Capacity:                     65AH

  • Model:                     12V65AH

  • size:                     350*166*174(mm)

  • Nominal Capacity:                     65AH

  • self-discharge:                     <2%/month

  • packing:                     cartoon

  • use:                     maintenance free battery

Packaging & Delivery

Packaging Details:cartoon and plyhood packing or according to our clients' demand.
Delivery Detail:7-15 weekdays maintenance free battery

VRLA maintenance free battery with 10 years life design 12v 65Ah 

1)deep cycle and maintenance free 

2)MSDS,ROHS,ISO9001,ISO14001,CE,TLC,SGS

3)export experience 15 years

Product Description

 

Item 

  12V 65AH maintenance free battery   

Model NO. 

  LCPC65-12

Battery type

  storage battery

Battery dimension

 350*166*174(mm) (L*W*H)

Nominal voltage

  12v

Nominal capacity

  65ah

Net Weight 

  22kg

Cycle life 

   100%DOD  572times , 50%DOD   1485 times , 30% 2406times 

Battery Case

    ABS

Plate

    lead-antimony

Payment terms

    T/T(with 30% deposit),70% paid by the copy of BL

Loading port

   Shanghai

Main Market

  America,Africa, Mid-east,Asia ,South America, Europe 

Q:What are the technical parameters of the battery?
The main performance parameters of the battery are the following: model; voltage; battery capacity; battery type, such as lead-acid batteries, alkaline batteries, lithium batteries, solar cells, fuel cells.
Q:Battery 200ah / 104 what does that mean?
Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
Q:How to determine the battery is good or bad?
If less than 9V but the pointer is in a certain value does not move that the battery is in a state of loss, need to add charge.
Q:What is the difference between a maintenance-free battery and a conventional battery?
Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
Q:How does the battery increase the voltage?
The so-called battery is the storage of chemical energy, if necessary, the release of electrical energy of an electrical chemical equipment.
Q:80ah how much battery storage capacity?
Is 80AH. Understood to discharge at 80 amps for about 1 hour (but not to say that after 1 hour is finished, there is still electricity). In theory, this is your battery power.
Q:What are the advantages of maintenance-free batteries?
Maintenance-free battery because of its normal charging voltage, the electrolyte only produce a small amount of gas, so throughout the use of the need for the addition of distilled water, in the normal charging system, do not need to remove the charge from the removal. But in the maintenance of the proportion of its electrolyte should be checked.
Q:What are the hazards of battery over discharge?
When the battery discharge current is large, the heat will become more obvious, there will be serious heat generated when the battery deformation, when the concentration of lead sulfate is particularly large, will form a larger crystal particles, that lead to the battery Internal irreversible sulfation.
Q:How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q:How should the battery be well maintained?
Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords