Battery the EosG series batteries EosG1500

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1000 unit
Supply Capability:
4000000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Range summary

The EosG range of gel technology batteries offers outstanding performance including  a 15+ years design life .

The EosG series batteries is designed based on the Eos series.

Using the polymer gel electrolyte .

Built to the highest standards and compliant with the latest IEC60896-21/22 standard .

This range also offers 100% capacity out-of-the-box and is capable of handling deep discharges for complete peace of mind. The use of flexible  connectors and the ability to be installed  both horizontally and vertically allows for multiple installation possibilities.

Technical features

  • Above 15 years designed life

  • Reliable post sealing structure

  • Excellent charging acceptant ability

  • Excellent performance at extreme high  and low temperature

  • Low self-discharge ability

  • Flexible and convenient installation  with slinky outside looking

Type:

  EosG1500

Voltage:

  2V

Nominal Capacity:

  1500Ah(C10)  1500Ah(10 hours rate:)

Length:

  265.5mm

Width:

  229mm

Height:

  555mm

Height   with termial:

  566mm

Weight:

  93Kg

 

Compliant standards

    • IEC60896-21/22

    • BS6290 part 4

    • Telcordia SR4228

    • Eurobat guide

    • UL

    • Manufactured under system ISO9001(TUV)                                          

    Battery installation compliant with:

    • EN 50272-2 or local equivalents

    Main applications

    • Correspondence exchange and transmission system

    • Mobile communication system

    • Power plant and power transformer system

    • Navigation and signaling system

    • Solar energy system

    • Radio and broadcasting station

    • Emergency lighting system

    Products characteristics:

    • Plate special patent calcium and tin  lead alloy and thick plate design

    • Container ABS(V0 optional)

    • Separator AGM

    • Valve EPDR

    • Electrolyte using the polymer gel electrolyte

    • Terminal M8 copper core posts

    FAQ

    What is sulfation of batteries?

    Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

    How long a battery can last?

    The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

    Do batteries self-discharge when not in use?

    All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.

     

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to repair the battery?
Pry open the adhesive or heat-sealed battery cover, reveal the maintenance-free battery rubber exhaust valve, carefully remove the exhaust valve, save, observe the battery internal situation. Add 0.1% to 0.5% of the electrolyte to the battery, just to the battery above the flow of electrolyte. At the same time, check whether the black impurities, if there are obvious black turbid impurities, indicating that the battery plate has been significantly softened, the possibility of battery repair is relatively small. If there is no black muddy impurities, need to wait 4 hours later, the water fully into the battery. If it is only because the deactivation time is long and cause the battery capacity to decline, do not need to carry out this step operation, should go directly to step 3 pre-charge.
Q:What are the advantages of maintenance-free batteries?
The advantage of a maintenance-free battery is that the service life is twice as long as the dry battery! And in the use of the process without maintenance! The voltage is also relatively stable.
Q:What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V.
Q:Lead-acid battery how to maintain?
After 5 hours of repair, the excess electrolyte is sucked out with a straw, and if the electrolyte is sucked out into black, it indicates that the battery is severely grounded and that the battery is difficult to repair.
Q:How does battery activation work?
Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.
Q:80ah how much battery storage capacity?
The size of the battery storage power refers to the battery capacity. Battery capacity is generally calculated in AH (safety). You 80Ah battery capacity is 80Ah, meaning that if you discharge current to 80A, you can put an hour.
Q:How is the capacity of the battery defined?
General circuit has a battery protection circuit, once the battery voltage is less than 10.8V will automatically cut off the electricity to prevent the battery because of over-discharge and damage. (Nominal value of 12V battery internal six cell grid) with the battery discharge current multiplied by the discharge time to express how much energy the battery can store, is a very image of a measure. The greater the value of the battery, indicating that the battery can store more energy. But does not mean that the battery can use such a large current discharge.
Q:What are the technical parameters of the battery?
Battery capacity is defined as ∫ t0tdt, theoretically t can be infinite, but in fact when the battery discharge is lower than the termination voltage continues to discharge, which may damage the battery, so t value is limited, the battery industry, in hours (h) Battery sustainable discharge time, feel the C24, C20, C10, C8, C3, C1 and other nominal capacity value.
Q:The role of the battery?
Battery is widely used, can be used for ups, electric cars, scooters, cars, wind energy solar systems, security, and so on.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range