Product Description:

Range summary


313K Series batteries are designed for high-temperature environment and new energy such as wind energy, photovoltaic energy storage system. With high temperature resistance, long life, safety and reliability characteristics, 313K series is widely used in telecommunications, electric power, energy storage, and it ideal for cycle or hybrid system in harsh, high temperature environment.
The 313K series batteries are ensured the quality with NARADA's QA system according to the ISO9001&ISO14001 standard.


Features and Benefits

1.     Patented anti-corrosion grid technology

2.     Optimized active material for high temperature conditions

3.     Unique high temperature case material with HDT in excess of 124oC

4.     Increased internal compression for improved cycling endurance

5.     Oxygen catalyst to reduce float currents and extend cycling capability

6.     Containers & lids UL94 V-0 rated

7.     Advanced negative plate protection system

8.     Wide operating temperature range:-40oC to +80oC

9.     Normal operating temperature is 35oC

10.  Excellent deep cycling capability systems

11.  Suitable for continuous operation at temperatures in excess of 35oC

12.  Reduced system operating costs 25% electricity power saving

13.  Up to 100% air conditioner maintenance saving

14.  Up to 100% condensing agent saving

15.  30% CO2 gas emission reduce

16.  Less than 1 year payback period depend on environment

Compliant standards

1.     IEC60896-21/22

2.     IEC61427

3.     BS6290 part 4

4.     Telcordia SR4228

5.     Eurobat guide

6.     UL

7.     Manufactured under system ISO9001(TUV) and ISO14001

Battery installation compliant with:

1.     EN 50272-2 or local equivalents

Main applications

1.     Hybrid telecom remote base stations

2.     Renewable energy wind & solar sites

3.     Grid frequency leveling systems

4.     All back-up applications where grid reliability is poor

5.     All extreme environment off-grid

Products characteristics:

1.     Recommended float charge voltage for 2V battery: 2.24Vpc at 35oC(95oF), 2.27Vpc at 25oC(77oF)

2.     Self discharge rate :<5% per month at 35oC(95oF)

3.     Design life: 15 years at 35oC (95oF)

4.     VRLA high temperature battery, no water addition required

Technical Data:

Battery Solar Wind Power System High Temperature 2V 1200AH


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between a maintenance-free battery and a conventional battery?
As a result of maintenance-free batteries using lead-calcium alloy grille, the amount of water generated when charging less water evaporation, coupled with the shell with a sealed structure, the release of sulfuric acid gas is also very small, so it compared with the traditional battery, With no need to add any liquid, the wiring pile head, wire and body corrosion less anti-overcharge capacity, starting current, power storage time is long, by the car people welcome.
Q:Battery 200ah / 104 what does that mean?
This should be refers to 2V200AH battery 104, power with the 220V.
Q:How does battery activation work?
If the battery is charged, because the battery discharge itself, the active substance to activate, not add acid, but should be added pure water (no minerals and impurities in the water) is best steaming water, and now you Since the addition, you can use water to wash several times, and then use 1C current charge to 2.3 times. Then discharge, so repeated several times, will be better. So that you can remove the vulcanization.
Q:What is the meaning of the battery above 12v65Ah?
12V represents the rated voltage. 65Ah indicates that the battery capacity (ie 1 ampere current can be used for 65 hours).
Q:How is the capacity of the battery defined?
General circuit has a battery protection circuit, once the battery voltage is less than 10.8V will automatically cut off the electricity to prevent the battery because of over-discharge and damage. (Nominal value of 12V battery internal six cell grid) with the battery discharge current multiplied by the discharge time to express how much energy the battery can store, is a very image of a measure. The greater the value of the battery, indicating that the battery can store more energy. But does not mean that the battery can use such a large current discharge.
Q:What are the hazards of battery over discharge?
The battery discharge to the standard termination voltage when the internal resistance will become larger, the battery electrolyte concentration will become very thin, especially the battery plate micropores and battery plate surface these two points are almost neutral; battery over discharge because of Internal resistance will become larger, so the battery will appear inside the phenomenon of heat, the battery volume will appear fever expansion.
Q:What are the technical parameters of the battery?
The main performance parameters of the battery are the following: model; voltage; battery capacity; battery type, such as lead-acid batteries, alkaline batteries, lithium batteries, solar cells, fuel cells.
Q:What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q:What battery does the van use?
The most obvious feature of lead-acid batteries is the top of the plastic cover can be unscrewed, there are ventilation holes above. These fillers are used to fill pure water, check the electrolyte and the use of exhaust gas. In theory, lead-acid batteries need to check the density of each electrolyte and the level of liquid, if there is a need to add distilled water. But with the upgrading of battery manufacturing technology, lead-acid battery development for the lead-acid maintenance-free batteries and colloidal maintenance-free batteries, lead-acid batteries do not need to add electrolyte or distilled water. Mainly the use of positive electrode to produce oxygen can be absorbed in the negative oxygen cycle, to prevent water reduction. Lead-acid water batteries are mostly used in tractors, tricycles, car start, etc., and maintenance-free lead-acid battery wider range of applications, including uninterruptible power supply, electric vehicle power, electric bicycle batteries. Lead-acid batteries according to the application needs to be divided into constant current discharge (such as uninterruptible power supply) and instantaneous discharge (such as car to start the battery).
Q:The role of the battery?
Battery is widely used, can be used for ups, electric cars, scooters, cars, wind energy solar systems, security, and so on.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range