Axial Flow Pump From China Coal with High Quality

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
1000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Axial Flow Pump From China Coal with High Quality


1) Features:                A) Vertical structure
                                                   B) Fitted with vertical motor
                                                   C) Long shaft
                                                   D) High efficiency

                                                                    E) Good vapor erosion resistance



2) Applications:
                                                                     A) Hydraulic projects
                                                     B) Farm-land irrigation
                                                     C) Industrial water transportation
                                                     D) Water supply and drainage
                                                     E) Water allocation engineering



3) Technical data:
                                                      A) Flow: 83 - 48, 888m3/h
                                                      B) Head: 1 - 30.6m
                                                     C) Medium temperature: 50oC
                                                     D) Operation pressure: 2.5Mpa
                                                     E) Diameter: 350 - 1, 800mm
                                                     F) Power: 4 - 20, 00kW
                                                    G) Voltage: 355kW, 6kV, 10kV

 

4)Material Standard:

                                                                   A)Casing: cast iron 

                                                                   B)Impeller:cast iron/ Carbon steel/stainless steel

                                                                  C)Shaft: Carbon/Cr-steel

5)Pictures


Axial Flow Pump From China Coal with High Quality




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Variable flow variable frequency water pump how to adjust the flow?
Variable frequency pump is mainly depending on the frequency converter to adjust the speed of the pump motor, thereby regulating the flow and lift pump, the following Q1/Q2=n1/n2; H1/H2= (n1/n2) -, the frequency range of the frequency converter in 30HZ~50HZ
Q:What are the conditions for the series and parallel connection of the pumps?
1, pump series, the two pumps must start and stop at the same time in order to normal operation.2 when the pump is connected in parallel, the two pumps must be equipped with check valve at the same time to operate normally.3, of course, in the election of the pump, should meet the requirements of upstairs said.
Q:Horizontal pumps, vertical pumps, which kind of expensive?
Vertical multistage pump is expensive, little water, big pressureHorizontal water pumps, instead, are mainly used for spraying
Q:The diving pump in the aquarium stops and stops on the goldfish
Submersible pump is used as if you push the pump filtration should be open for 24 hours, so the water circulation process, continuously into the fresh air to increase the oxygen content of water bodies two, filter on the filter of the continuous cleaning system to maintain water make nitrification safe and clean, the water can be fully introduced the content of nitrification ammonia water, let the fish live healthy and strong resistance, good activity, three appropriate water flow on the long time to keep fish, turn off and the formation of water to fish is always in a state of tension and decreased immunity antifeedant or death. Four, frequently start the pump, easy to cause damage to the motor coil, reduce pump life, so according to the above, if you are using submersible pump as a filter to promote, I suggest you open 24 hours.
Q:Why does the water pump in the tank pull out the power supply and then plug it in?
What kind of filter pump? If you don't pump water, there may be a blockage in the foreign body. You can either take a look or fail to reach the level of water it needs
Q:1.5 kW three-phase pump with 600 meters line, should match what big line?
Do you want to see the line loss how much pressure drop, if you want to ensure the working voltage of certain you pump, 600m pressure drop should be two-way, namely power press 1200m, press 380V, 1.5KW working current is calculated according to 3A R=, according to the resistivity * length / cross-sectional area of =0.0175*1200/S=21/S, and the loss of pressure drop =R*I=21*3/S=63/S, S take 3, loss of pressure drop is about 20V, the comprehensive economic cost, take 3 more appropriate, if you are willing to take 5, 6 are never mind, the thicker the loss is smaller.
Q:The problem of single phase pumps
Is your starting capacitor pump is broken. Because you pump it is a single asynchronous motor..... Single-phase asynchronous motor by capacitive phase shifting function, the single-phase alternating current isolated from another 90 degree phase alternating current. The two alternating current into two groups or four groups of motor winding, forming a rotating magnetic field inside the motor rotating magnetic field induced current in the rotor, the induced current magnetic field and rotating magnetic field in the opposite direction, by rotating magnetic field push pull into the rotating state, because the rotor must be cutting magnetic lines to produce induction current, so the rotor speed must be lower than the rotating magnetic induction motor speed, so thatSo if the starting capacitor is broken, then your pump will start difficult,
Q:What's the meaning of a single-stage pump?
I. meaning:Single stage and multistage refers to the number of impellers. Generally equal lift and flow, multi-stage pump than single stage pump power is low, that is, to save power, and high efficiency, long life.Two, how to distinguish?:Water pump said double suction refers to both sides of the water pump has suction port, and single suction pump only from the side of water absorption, single suction pump flow is small, double suction pump flow larger. The axial flow pump blade is a little like the blade of an electric fan. The axial direction of the axial flow pump is smaller, and the flow rate is relatively large, which is mostly used in the first stage pumping station of the water plant. JC is a deep well pump, with a large lift, but the flow is often not large. Centrifugal pumps are the most widely used at present.
Q:Why can't vertical water pump use spring shock absorber?
Vertical pump power is small, the weight is limited, the pipeline vibration is limited, the general rubber shock absorber will be enough. It's no use. I'm sure you can't use the spring shock absorber.General construction, 7,5KW below is rubber shock absorber, above is spring shock absorber
Q:How much is the flow rate of fire hydrant and spray shared water pump?
Fire fire water is superimposed, at the minimum, the lowest 5L/S automatic spraying fire hydrant, light danger level 13.9L/S, the least is 18.9L/S, but the data is useless, the data are not spraying fire hydrant, concrete analysis of high-rise buildings like the dangerous level according to the calculation, the general design, the concrete building needs the high-rise building minimum 20L/S, automatic spraying dangerous level according to the general 30L/S, 50L/S need to flow

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range