• Axial Flow Pump For Irrigation System 1
Axial Flow Pump For Irrigation

Axial Flow Pump For Irrigation

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
5000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Packaging & Delivery

Packaging Detail:Standard export wooden case
Delivery Detail:Within 25 days after receiving deposit

Specifications

a. High pressure axial flow pump has huge capacity
b. Low head
c. Easy operation
d. Long service time
e. Test strictly

High pressure axial flow pump

Operating Data:

Outlet Diameter:350-2000mm

Capacity: 500-52000m3/h

Head: 2-8m

Rotation Speed: 580-1450r/min

Power: 7.5-1250KW

Detailed Product Description:

a. Vertical single-stage pump

b. High efficiency

c. Easy maintenance

d. ISO9001

e. OEM Service

Application:

a. High pressure axial flow pump apply to flood control, hydraulic projects.

b. Apply to water supply, industrial drainage.

c. Apply to power plant circulation.

d. Apply to agricultural irrigation.

Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q:Working principle and diagram of axial piston pump with pressure compensation variable
The size of the outlet flow pressure compensated variable displacement pump with outlet pressure of approximately in a certain range according to the constant power curve. When the pressure oil from the main part of the channel (a), (b), (c) into the inferior vena cava (d) variable shell, oil by the channel (E) respectively into the channel (f) and (H), when the spring force is greater than the oil (f) into the lower end of the piston ring servo hydraulic thrust area when the oil liquid (H) to the chamber (g), push the variable downward movement of the piston, the pump flow increases. As for the hydraulic servo piston end thrust force ring shaped area is greater than the spring when the servo piston moves upward, blocking channels (H), the (g) (I) through the cavity of the oil cavity pressure relief, at this time, the piston moves up, the variable head angle decreases, the pump flow rate decreases.
Q:Why adjust the centrifugal pump outlet valve can adjust the flow? What are the advantages and disadvantages of this method? Is there any other way to regulate the flow of the pump?
The use of frequency converter to adjust the speed of the motor can also adjust the flow, the advantage is to save electricity.
Q:What are the constant pressure pumps?
Chlorine booster pumpThe pressure range of chlorine booster pump is large, and different pump can be used to obtain different pressure area. The input air pressure is adjusted and the output pressure is adjusted accordingly. High pressure can be reached, gas 90Mpa. Wide range of flow, for all types of pumps only 0.1Kg pressure can work smoothly, at this time to obtain the minimum flow, adjust the intake volume can be obtained after a different flow. Easy to control, from simple manual control to fully automatic control, can meet the requirements. Automatic restart, regardless of what causes the pressure drop in the pressure loop, will automatically restart to supplement leakage pressure and maintain constant loop pressure. Safe operation, gas driven, no arc and spark can be used in dangerous situations.
Q:Fire pump and shower pump flow head selection, high resolution.
2, the volume is greater than 10000 is less than 25000, the minimum water consumption of indoor fire hydrant is 15L/s
Q:The distance from the pump button to the ground
After confirming that the fire pump has started running, issue a command signal to the hydrant button to light the green answer light.
Q:How does the centrifugal pump pump and cut the pump?
Check the motor, pump and fasteners in good condition; whether the lubricant is added or not;Disc dynamic coupling, whether or not stuck phenomenon;Open the inlet valve, remove the gas in the pump or pump the gas out of the pump;
Q:What is the cause of the damage of pump bearings?
Is the water pump motor overheating or damaged leaves overheating, resulting in overheating bearings, lubricating oil dry, excessive wear and tear guide system damage
Q:How accurate is the metering pump?
Three automatic compensation valve device widely used in diaphragm metering pump, especially with suction height requirements, can only be used by three separate Fujian (safety valve, discharge valve and oil supply valve) compensation device.
Q:What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system? How to choose in the project?
Pump control system is generally used for closed systems, the flow of the oil pump changes to control the motor or cylinder actuator action. The utility model has the advantages that the principle is simple, and the power of the engine can be fully utilized. The disadvantage is that the calorific value of larger, relatively poor precision.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords