Automatic Sliding Glass Door

Ref Price:
Loading Port:
China Main Port
Payment Terms:
Min Order Qty:
Supply Capability:

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Automatic Sliding Door :

1)automatic door
2)auto sliding door
3)auto door operator
4)auto glass door

our operator  has below 6 new technology which any other operators have not

1soft _start

As common automatic door,once open ,the motor speed up suddenly.the door not only swing terriblily but also have big noise.but we adopt slow_starting technology,the motor start slowly ,then speed up with frequency conversion in the base of the door are smooth.

2:automatic search

When the door knock someone or object,it will rebound swiftly,then search whether it be off slowly.

3:automatic protect

When search 3-6 times ,and insure the persone or object still there,the door machine will stop operating .

4:automatic .reset

After insure everything is safe,no need to close the power ,only push the door to opening position,the door will recover operating automatically

5:motor lock

Common automatic door locking force   >200N

But ours is >350N(equall strong electromaqnetism lock)

6:not increase the pressure when it is not work. high Efficiency and energy saving  

power consumption when work :220v  1.35A

power consumption when at waiting status.:220V 0.09A

For common automatic door ,when it is in waiting status.,the motor has electricity,not only have noise also heat effect motors life ,high power consumption.but we adopt excitation current,instantaneously pressurize technology,when the door donnt move,motor donnt have electricity.when someone wrench,motor has excitation current pass to the controller.then the controller will give a inverted strong current on the motor within 0.01S




Range of the Door





Door Leaf max Weight


90kg x 2


120kg x 2

Door Width





Installation Type

Surface Mounting

Max Door Leaf Thickness



DC24V, 65W

Power Supply

AC220±10%, 50-60 Hz

Input Current (Standby)


Input Current(Operation)


Opening Speed

250-550mm/s (adjustable)

Closing Speed

250-550mm/s (adjustable)

Creep Speed

30-100mm/s (adjustable)

Hold-open Time

2-20s (adjustable)

Hold-Close Force


Manual Pushing Force



Power Consumption


Ambient Temperature

-20+50 °C

Functional features:

(1)Exists in double and single sliding versions;

(2)Powerful and full functions: offer our users 4 operating options of full automatic,half open, constant open and constant lock;

(3)Flexibility:allows tempered glass door leaves as well as 50mm thickness wooden door leaves;

(4)Reliability:built-in microprocessor ensures the accuracy and precision of the operation;

(5)Safety:the door leaf(ves) will go backward when people or moving obstacles approach while closing,which prevents the clamp injury and damage of the door itself.

(6)The door leaf(ves) could be deftly manually opened at a power failure;

(7)Modularization design allows a simple and easy installation;

(8)Purpose made polyurethane covered silent wheels realize quiet operations;

(9)Multiple optional access method:

a.Sensors: microwave sensor,feet sensor;

b.Password:password or finger print identification access;

c.Card:IC card,RFIC card;

d.Button:Elbow touch,feet touch and long-distance buttons.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:my automatic door locks on the front pass/drvr side work intermittently with the remote or the door switch.?
Sounds like its the actuators in the door's an elecrical part and commonly goes out on some vehicles....I know neons have a huge issue with them, at least in my experience. Your biggest problem is, they are for the most part a dealer item only. Easy to install though. Hope this helped.
Q:What is the price of the Bill automatic door?
Smooth automatic door of the basic working principle is: installed in front of the door sensor infrared emission tube emitting a beam of infrared light, in the detection area to form a radiation surface, the radiation surface for the detection area, the light will be reflected in the target into this In a region, the infrared receiver detects and sends an electrical signal that reflects the red light. The signal is amplified, plastic input microcomputer. The computer according to the set procedures to command the motor and drive mechanism to work, so that the door set by the program to open, accelerate, full speed, brake slowly, close. When the door is closed when the door will be back when the obstacles, until the barrier is closed. As can be seen from the previous narrative, and then add some control components, by the controller can achieve more smooth automatic doors performance.
Q:why don't fast food restaurants have automatic doors?
Good question. They'd be a lot faster if I'm not deciding if the person inside is going to let me in first at the door or if they're going to let themselves out first. ARGH.
Q:Does it hurt a car if you manually shut a automatic door?
Nothing a little Prozac can't fix. Pop a few in the gas tank and it'll be all better. Just make sure it's not Viagra
Q:i have a 2005 malibu classic.when put in gear the doors lock automatic,but they dint.same as when cut off?
Do not fully understand your question, so I am guessing here. Automatic door locks - doors lock when you put it into gear. However they do not unlock when you stop, put in park, or shut ignition off. You must manually unlock them yourself by either the electric door lock/unlock button , or th emanual mechanisim on ht edoor.
Q:I think that the US science fiction film in the spacecraft on the automatic door now there?
Do you care about that? Do you want to install this door for your toilet?
Q:2002 Ford focus automatic door locks work somtimes and stop for a while, please help?
I just in case you get locked out and the automatic locks stop completely You should be able to pull the handle on the inside to make it unlock. If it won't unlock, then the problem is not the power lock unit, but the latch itself. Ford makes their latches unlock when the inside handle is pulled so that the door can be opened quickly in case of emergency, sort of a mechanical override for the electric locks. It may be unfortunate that you would then have to call a repair shop to come break in your vehicle using a jummy bar and hope that the latch works enough to jimmy it open. You won't be able to get it open any other way.
Q:Is the fire door a sliding door or a revolving door?
Roll gate and open the door, open the door as we usually push open the door, but the material and our ordinary door is different.
Q:What's the point of constantly working automatic doors in shopping places?
Somehow your question got Categorized as Computer & Internet Security. That may explain your lack of responses. You may find you will get more results if you resubmit the question with a more suitable categorization. As to the question, I suppose they figure the doors being closed at least some of the time helps with heat or A/C and likely helps keep out birds and other animals. D
Q:What is the remote control switch used by the automatic door?
The system configuration of the automatic door refers to the peripheral auxiliary control device, such as the door opening signal, the access control system, the safety device, the centralized control and the like, which are equipped with the automatic door controller according to the requirement of use. Must be based on the characteristics of the use of the building. Through the composition of the staff, building automation system requirements and other reasonable with auxiliary control device. 1, open the door signal is also called contact signal, microwave radar and infrared sensor is commonly used in two kinds of signal source; 2, key switch; 3, foot switch; 4, timer.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range