Automatic Revolving door four wings

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

KA023 - 3/4 WingsRevolving Door

The designs for revolving doors provide an imposing entrance to anybuilding, while serving as an airlock as well, to minimize a building’s heatingand air conditioning losses, therefore maximizing energy savings. The bestselling model called KA023 3/4-wing revolving door is not only elegant but alsoeconomical and practical.

Safety functions:

1. SpecialLoad-Bearing Structure

2. Vertical/horizontalsafety switch

3.Anti-squeeze

4.Anti-strike

5.Force-sensitive Control

6. TorqueControl

7. Panicbreakout system

8. Handicap

9. NightSecurity Door

Operation features:

1.Continuous working mode

2.Go/Stop working mode

3. Remotecontrol function

Technical Data:

Powersupply : 220VAC±10%,50HZ

Ratedcurrent :12VAC,50HZ

Ratedpower : 600W

Downlights : 400W

Highspeed adjustment range(revolving door) : 1-4r.p.m.

Low speedadjustment range(revolving door) : 0.5-1.5 r.p.m.

Ambienttemperature : -30 - 45 degree

Maxrelative humidity : 90%.

Totalweight :  <1000Kg

Operatingnoise : <= 60db (A)

Specifications:

Inner Dia(D)

1800mm

2100mm

2400mm

2700mm

3000mm

3600mm

Outer Dia (DT)

1880mm

2180mm

2480mm

2780mm

3080mm

3680mm

Clear height

2300mm

2300mm

2300mm

2300mm

2300mm

2300mm

Canopy height

300mm

300mm

300mm

300mm

300mm

300mm

Total height

2600mm

2600mm

2600mm

2600mm

2600mm

2600mm

Key Components:

1. Maincontrol unit : SIEMENS from Germany

2.Operation program software : KBB

3.Transducer :  SIEMENS

4. Driveunit :  SIEMENS

5. Gearbox : Sewdrive

6.Deceleration belt :  CONTITECH

7. Spotlight : PHILIPS from Netherlands

8.Detection radar : Infrared, BEA from Belgium

9. Highprecision speed /position radar : HENGSTLER

10.Emergency stop button : KBB

11.Handicap button : KBB

12.Curved glass : YAOPI, security laminated glass

13.Planar glass: YAOPI, security laminated glass

14. Aluminiumframe profile : JIHUA

Note : Similar with KA023, we hadanother model of 3/4 wings revolving door called KA061,different from KA023,there are several obvious pillars outside of  KA061 which covered the gaps on the doorsurface and make the whole door looks more aesthetic .


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:do automatic garage door opener adjustments become uncalibrated automatically?
sounds like one of the lift cables is loose or snapped. that door weighs quite a bit, with out that cable, you are going to hear some noise. the flat head would adjust the travel limits on the door. where it starts and stops, nothing else.
Q:Automatic door can not be opened normally how to do?
Automatic door can not be closed normally There are two cases, one is about the door action, but off a little to re-open. The other is the automatic door is always open state, can not be closed, or always keep the state closed, can not open. The first kind: the door movement, but can not close the situation, this reason is the sensor has a door signal input, that is, sensors within the scope of interference there are, such as: direct sunlight, active objects, there is not Stable light source and so on. It is possible to test whether or not the automatic door can not be turned off by turning off the sensor signal line by the sensor's interference signal. The second type: automatic door always remain open, causing the automatic door failure may be due to sensor damage, always have to open the door signal input to the automatic door controller, may be automatic door remote control or mode switch to adjust the open state, If the access control system is installed, it may be that the access control system is damaged. In addition, the automatic door can not normally open and close, you can also refer to the following automatic door repair solution: ● Cause The top of a door is in contact with the beam Treatment: adjust the gap between the door and the beam ● Cause The two doors are in contact with the ground rail Remedy: Adjust the door height ● Cause three doors derailment Remedy: Re-place the door in the track ● Cause The four doors are not vertical Treatment method: adjust the location of the track ● Cause Five sensors are faulty or are not wired to the hub Approach: 1. Replace the sensor if the sensor fails 2. Check that the sensor is connected to the hub Through the above analysis, should be able to basically solve the automatic doors can not normally open the automatic door failure, and in the actual automatic door repair should be simple and complex, first remove the simple reasons of automatic door failure, and then gradually troubleshoot other failures.
Q:What is the price of the Bill automatic door?
Smooth automatic door of the basic working principle is: installed in front of the door sensor infrared emission tube emitting a beam of infrared light, in the detection area to form a radiation surface, the radiation surface for the detection area, the light will be reflected in the target into this In a region, the infrared receiver detects and sends an electrical signal that reflects the red light. The signal is amplified, plastic input microcomputer. The computer according to the set procedures to command the motor and drive mechanism to work, so that the door set by the program to open, accelerate, full speed, brake slowly, close. When the door is closed when the door will be back when the obstacles, until the barrier is closed. As can be seen from the previous narrative, and then add some control components, by the controller can achieve more smooth automatic doors performance.
Q:Chrysler van - automatic door problem?
The wiring harness for the door (it looks like a plastic bicyle chain) has a broken wire. When the door slides back to a certain point, the wire comes apart. Replacement should be about $150-200 dollars. If you are handy, you can try to open up the harness and repair the broken wires.
Q:Automatic door opened when the door was detected and re-calculate the closing time, how is achieved?
By the microcomputer control gate switch process,
Q:what is the best automatic garage door opener?
I do not think any one brand is the best, although Genie does make a good machine, so do other companies. So rather than talk about brands I think it is much better to talk about features. A direct drive, screw type is the best. The reason why is because it has the fewest mechanical pieces inside. If you have few pieces and fewer things that move, obviously there are fewer things to wear out or go bad. Secondly is size. If you have a one car garage a 1/2 hp opener is plenty big. If you have a 2 car garage and only one garage door you will need a 3/4 hp machine. Thirdly is options. A wireless, keyless touch pad is handy and easy to install. You want two car transmitters. Other nice features are remote lights on only and a vacation lock to turn your system off if you are going to be gone for a long time. Thieves are very smart and given enough time and the right equipment they can open the garage door as easily as you can. By turning the garage door opener off lock position it becomes impossible for them to open it no matter how many electronic devices they have.
Q:How does the access control system control automatic doors?
You have a license card, when the card, the system will automatically identify, and then open the door.
Q:how do cold temps affect older automatic garage door openers?
I have two that are over 20 years old and they work just fine in colt temps.
Q:Electric revolving door has been kept non-stop why?
Usually the probe has a sensor swivel, stop switch failed to normal transmission of the signal, in question, plus my network name number, detailed to you
Q:Can the electric door be turned on by hand?
Yes. But very complicated.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range