automatic door manufacturer for exporting

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Place of Origin:
China (Mainland)
Brand Name:
CMAX
Model Number:
KS3000
Open Style:
Sliding
Position:
Commercial
Surface Finishing:
Finished
Type:
Sliding Doors
Door Material:
Aluminum Alloy
motor:
Dunkermotoren
main control unit:
Philips from Netherland
radar:
Optex
photocell:
BEA
supporting beam:
5mm thickness aluminium alloy
Durable Rail:
made of special Nylon, quiet, self lubricating,wear resistance
Electro Mechanical Lock:
Bi-static
Backup battery:
60 minutes work when power failure


Packaging & Delivery

Packaging Detail:Wooden Cases, could meet international shipping packaging perfectly .
Delivery Detail:10 work days .

Specifications

1.6 High technology
2.Frame automatic door
3.Stainless steel frame
4.Automatic sliding
5.Good quality


Safety Features:

1. Safety beam which installed in the fix-door frame.

2. UPS backup battery ensures the door operates 30 minutes normally if power fails.

3. Install an electro-mechanical lock to ensure the door be locked more safely.

4. Panic breakout: CMAX sliding door could assemble this function, which could open during emergency time or oversize object.

Technical Data:

1. Maximum Door Weight ( Single Parting ) : 1 × 150kg.

2. Maximum Door Weight ( Bi - Parting )  :  2 x 120 kg.

3. Opening Speed Range: 0.4 - 0.7m / s (adjustable).

4. Closing Speed Range: 0.3 - 0.6m / s (adjustable).

5. Keep Opening Time Adjustable Range : 5~10s (5s, Standard) .

6. Power supply: 220VAC±10%,50HZ ,10A .

7. Rated power: 100W .

8. Max. drive power (static): 150N .

9. UPS backup battery:  30min .

10. Ambient temperature: -30.C – 50.C

11. Max. relative humidity: 90% .

12. Protection level: IP23 .

Key Components:

1. Main control unit -Philips –Netherlands

2. Motor - Dunkermotoren – Germany

3. Radar - BEA (Belgium)/OPTEX(Japan)

4. Durable rail - Special nylon, durable, quiet and self-lubricated

5. PSA control Panel - 37 parameters could be set.

6. Supporting rails - High strength, 5mm thickness

7. Carriage wheel

8. Operator Cover - optional
9.Infrared Safety beam - optional
10.Key switch - optional
11. Ups backup battery - optional

12.Electro-mechanical lock - optional.
13. Double drive unit - optional

OTER TYPES


Automatic Door

Automatic Door

Automatic Door




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:how do cold temps affect older automatic garage door openers?
cold temps really don't affect the openers as much as it does the garage door, which in turns makes the opener work harder. I usually try to tell my customers to make sure that they oil (not grease or any type of spray grease because it gets stiffer as the temp gets colder) with an oil can and regular motor oil. oil all the rollers pulley wheels and or bearings twice a year, right before winter and right after winter because the cold temps make everything on the door work harder. disconnect your door from your opener and see how it works buy hand, it should be rather easy to lift - not heavy. if so, it may need some tension added to the springs. with the door unhooked oil all rollers and pulley wheels. open and close your door 5-6 times to work in the oil. give them all another little shot of oil. open/close your door couple more times. your door should be running smoothly now. check for worn out roller and pulley wheels. if bad replace them. hook your door back up to the opener and see how it works now. the rule of thumb - the easier the door works the longer the opener will last.
Q:Automatic doors should be checked for daily use
Automatic sensor door application is very extensive, a set of automatic doors after the installation is completed daily use, and automatic use of the door in the daily use of the best time or check the automatic doors, the saying goes, if a small problem dragged on for a long time Become a big problem, then the automatic door should check what day? The following OKorder Hongsheng Xinhui automatic doors for everyone to share the automatic use of the door should be checked what daily use. If the automatic sensor door installed infrared anti-clip device, when the automatic door open, hand-blocked infrared sensor eye automatic door will not close. Observe the normal movement of employees through the automatic door route, automatic sensor door sensor area should be in accordance with the staff to take the angle of induction. The width of the induction door is greater than the width of the door when the automatic door is fully open. Normal go to a certain distance before the door will automatically open the door, and run to be smooth and mute
Q:How is a photocell used in an automatic garage door opener?
Used Garage Door Opener
Q:Automatic Garage door only opens 2 inches?
if you're sensors were out of line it would be just the opposite, the door would not close unless you were physically there pushing the button, telling the opener that there is nothing there to damage it that the sensor is reporting stop in error. Two things that might be happening is that your open limit setting might have gotten changed, but if it is opening to the correct limit when you hold the switch then that's not it. You will probably have to increase the UP force that the opener uses when raising the door. You will adjust your force by either turning a setting screw or by changing the program with the control buttons on the opener. I don't know how old your door is, but also check to make sure there is not a broken spring. A spring will also weaken with age resulting in more force needed to raise the door. Lube up your spring with wd40, and spray the rollers. Try raising your door half way up and have someone release the opener from it. If it is heavy and hard for you to lift, call a door company and have them re tension your spring. When I tension springs on a double wide door you would be able to raise and lower it with only a couple of fingers
Q:What is the design principle of the automatic credit card?
Basically, it is simple, that is, you do after the automatic door, do not feel sensitive probe. Automatic door open signal from the card reader to provide! That is, after the card, the card reader or access control machine output a closed signal, automatic door after receiving this signal, open the door!
Q:automatic garage door will not stay closed because slab is pushed up by ice. anything i can do?
If it has the IR eyes you can bypass them by re wiring them at the power control box. Or you could use the emergency release and open and close it manually. Sometimes you can also adjust the sensitivity on the back of the motor to control when it will open and close.
Q:What keeps a automatic door opener closed?
they are held by motor that has been locked kinda,what happens is when the door gets to the end of the cycle that is programed into it,the motor stops in a locked position until the door opener is hit again then it runs through its cycle again,only in the oposite position
Q:Automatic door how to open and then enter, and so close the door and then open?
It should be to receive the signal after the re-timing, sensor detection signal or other open signal control time relay opening and closing, time relay control door to open the door to keep it.
Q:Where is the speed of the automatic door?
LZ attention can basically be able to debug the national standards which are on the request is not the so-called "high-end machine can be"
Q:Can the electric door be turned on by hand?
Common electric doors generally have two! One is the electric sensor door (sub-open and translational type), this door after the power outage only need to push to open! There is also a curtain, electric device at the top of the door, usually after the decoration is invisible, only one chain outside the ceiling. After the power outage need to manually move in a direction to slowly open the chain! The The Not common in the use of financial units, with access control. Need to password or fingerprint identification system to open, power outages are generally open, unless it is to use high-tech crack or man-made damage Caixing! Do not ask friends to personally try yo! The The

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range