Assembled prefabricated branch cable FZ-W-3

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

I. Characteristics of the cables
1. Using factory prefabrication methods can substantially reduce the site construction labor intensity and shorten the construction laying time;
2. Use of cables can guarantee great length and bending property, and greatly facilitates the construction in a complex place;
3. Use of cables reduces the laying space, and cables can be installed together with gas and hydraulic gas pipelines;
4. Their reliability and reliability can be fully guaranteed, for the cables are manufactured in the factory,
5. Sub-branch parts should use high strength sealed joints, which are waterproof and have properties of moisture protection, long-term maintenance and free for repair;
6. Because the cables are directly connected with households with no need of maintenance and repair and with easy and simple construction, the cables can produce significant comprehensive economic benefits.

 

II. Usage of the cables:
1. To be used for high-rise building;
2. To be used for disaster prevention equipments;
3. To be used for tunnel lighting and disaster prevention equipments;
4. To replace copper bus bar with small or medium capacity in various places.

 

III. Standards of the cables
IEC 60502 Rated Voltage 1 ~ 30KV extruded insulated power cables and accessories (International Electrotechnical Commission standards)
GB 12706 Rated voltage 35KV and below Copper core, Aluminum core plastic insulated power cable (National Standard of the People's Republic of China)
JCS 376 branch cable (Japanese Electric Wire Industry Standard)
General Rules for JIS C2810 indoor wiring electrical connection pipes (Japanese Industrial Standard)

 

Types of the cables:
Standard main cables and branch cables are all low-voltage power cables with XLPE or PVC insulation materials (IEC, GB, JIS, BS ... ...), and PVC materials covered on the outer side. Generally, the main cable is single-core or twisted multi-core cable (cables with two to five cores), the branch cables are single-core cables, and may adopt a fire-resistant, flame retardant cables in accordance with the requirements.

 

Their structures and types are as follows:

No.

Cable Description

Type

single core

three cores twisted type

four cores twisted type

five cores twisted type

1

PVC insulated PVC sheathed branch cables

FZ-W

FZ-W-3

FZ-W-4

FZ-W-5

2

PVC insulated PVC sheathed flame-retardant branch cable

FZ-ZRVV

FZ-ZRVV-3

FZ-ZRVV-4

FZ-ZRVV-5

3

PVC insulated PVC sheathed fire-resistant branch cable

FZ-NHVV

FZ-NHVV-3

FZ-NHVV-4

FZ-NHVV-5

4

Cross-linked polyethylene insulated PVC sheathed branch cables

FZ-YJV

FZ-YJV-3

FZ-YJV-4

FZ-YJV-5

5

Cross-linked polyethylene insulated PVC sheathed flame-retardant branch cables

FZ-ZRYJV

FZ-ZRYJV-3

FZ-ZRYJV-4

FZ-ZRYJV-5

6

Cross-linked polyethylene insulated PVC sheathed fire-resistant branch cable

FZ-NHYJV

FZ-NHYJV-3

FZ-NHYJV-4

FZ-NHYJV-5

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Ps3 Power Cable Question?
Yah, It will work, but your computer wont XD. Use it temporarily and get your cable back A.S.A.P.
Q:What type of high power cable for 3 phase shielded?
There's not enough information in your question to give an exact answer. Figure the highest current in any of the phases assuming that your load may not be perfectly balanced or it may have a nonlinear current waveform. That will establish the minimum size of the conductors. Another factor to consider is the maximum allowable voltage loss at full current. You also need to know if voltage sags due to startup or inrush currents will be a problem. A long cable will need to have larger conductors to keep the losses within your acceptable range. Don
Q:car audio power cable sub/amp to car battery question, 10 points?
buy a new end piece from a radio shack, you can hookem up pretty easily. i answered your other question too, but i just wnat the extra 10.
Q:Why does my laptop shut off when I remove the power cable?
Your battery may not be any good anymore. You may need to get a new battery.
Q:Power cable thickness for 4 Amps?
yes. Resistance, and therefore voltage drop, is inversely proportional to the square of the radius or diameter. in other words, cut the diameter in half to 3 mm, the current capability would be 1/4 or 6 amps. 25/4 = 6.25, and square root of that is 2.5, and 6mm/2.5 = 2.4 mm, using only voltage drop considerations. If temperature in the wire is important, it gets more complicated, as you have to consider physical size of the wire, insulation type and thickness, etc. Of course wiring codes would override all this.
Q:Can i make a USB cable that has one plug for data and one for power by putting two together?
Yes I'm sure this would work. Just solder the red and black wires to an other usb cable and leave the other 2 data ones going into the computer. Plug the power usb cable into your adaptor and It should work. The device is still getting the 5volts it needs so I see no reason why it shouldn't work.
Q:Hi I hope there is help out there... I have a power cable for a dishwasher from Best Buy not colorcoded.?
stripe to white black to plain wire green to chassis. The white is neutral black is line bare wire is green
Q:Cable modem issues--help please?
Ok, the send and recieve lights are supposed to flash, this is good. the connected light should be steady and the connected to pc light can flash if it wants the slow connection could be many things call your cable computer and ask them what to do if there's nothing wrong with your cable settings, run a virus check, spyware check, and adware check. possibly restore your entire pc to factory condition.
Q:What is the meaning of "cable tray: 200 * 100 middle strip" in electrical engineering
In addition to considering the security issues, there is no problem, you can use this, there is no impact on the charging situation, rest assured
Q:What is the Best RG59 Cable?
Years ago, Belden made the best RG59, but that may have changed by now. I can't imagine anyone using RG59 any more, unless they are co-phasing mobile CB antennas... or setting up CCTV systems. Cable and satellite TV providers long ago changed to RG56, and then to RG6, because RG59 has excessive losses at some of the frequencies used for these services. As to prices, compare the cost of the same thing from at least five different sources.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range