Articulated Boom Lift

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or L/C
Min Order Qty:
4 Sets m.t.
Supply Capability:
30 Sets Per Month m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

GTQZ series self-propelled boom lift

can drive flexibly and freely, with side working scope and high efficiency. Hydraulic motor realize 40% grade-ability through planetary

 reduction box. Telescopic boom and cylinders are protected with dust proof jacket to prevent dust in.

GTQZ Aerial work plaftform application

generally used for temporary, flexible access purposes such as maintenance and construction work or by firefighters

for emergency access, which distinguishes them from permanent access equipment such as elevators. They are designed to lift limited

weights — usually less than a ton, although some have a higher safe working load — distinguishing them from most types of cranes

. They are usually capable of being set up and operated by a single person.


Max. working height(m): 17.3

Max. platform height(m): 15.5

Travelling when lifts(kg): 8100(12 boom)

Max. lifting torque(kN m): 2062

Boom length: 12~30(standard configuration 18m)

Working range: 4~29(outriggers extended)

Elevation range: 22~77

Max. lifting height(mm): 27650 (with 30 boom)

Axle base(mm): 2650+1300

Wheel base fromt/rear(mm): 2400/2400

Ground clearance(mm):225


Min. turning diameter(m): 20

GVW(with 12m boom)(kg): 49700

Outigger type: H type

Machine dimension(without boom)(L×W×H)(mm): 7460× 3315× 3710

Machine dimension(with 12m boom)(L×W×H)(mm): 17150× 3315× 3710



Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the safety device for construction elevator?
A lot of 1, anti-drop safety device 2, upper and lower limit 3, extreme limit 4, buffer spring 5, line door limit switch Single line door limit switch 7, ceiling switch 8, enclosure door lock 9, single door lock The door lock is on and off There are also many electrical safety protections
Q:When building tall buildings, the machine that USES to lift concrete to wait for tall building
It should be the ground pump, the center is the tower crane, the construction face is the concrete pump of the cloth machine to the construction method. The advanced cloth machine is the arm bracket of the pump car, can operate with the remote control, is as convenient as the pump car.
Q:How many floors do you need to install a construction elevator?
Do not have a regulation, as long as the benefit construction organization, installation does not install construction lift machine all can. It should be explained that the construction elevator has manned and pure cargo.
Q:The maximum allowable deviation of the vertical is the vertical degree when the construction elevator is installed
The development of the elevator is in a peak state, because most of the manufacturers or individuals to improve the utilization efficiency of space, more options for multistory buildings, which also need a device to convenient up and down by the goods. Due to the common elevator cost is high, bearing capacity is low, not suitable for carrying dozens of tons or hundreds of tons of cargo, so developed a high bearing capacity of hydraulic lift to assist in the production and transportation of goods. The elevators are both safe and super loadable, and convenient for maintenance, making the special industry grow faster.
Q:Do the elevator need to be installed when the main project is in construction
Installation, of course. The general building should be installed at about 10 meters on the 4th floor, or the person will go up and down the time is dangerous, and there will be some materials that can't be carried by the tower, too slowly
Q:Where is the location of the elevator in the project
Construction elevator location setting, need to take into consideration the situation of the scene and the layout of the building, should consider the following factors: To facilitate the conveyance of material transportation, choose the more spacious rooms in the layout of the floor as import and export; The outside of the elevator is as spacious as possible, with construction channels and materials. The construction materials are minimized in the floor, usually in the middle of the flat. The construction personnel are handy; Monomer building expansion joints at the junction, traffic between unit set up by the elevator capsules export operation platform is completed, so the corresponding reduced floor wall body of the reserved hole lien expansion joints
Q:How long does the construction elevator do a crash test
Construction lifter before put into use, must pass a drop test, using every three months should do a drop test, to adjust for safety device, braking distance will be falling not more than 1.2 m, after test and normal operation of every happening for action, must be to reset the attached safety device. The adjustment, repair, or identification of the anti-falling safety device shall be carried out by the manufacturer or designated authorized unit, which shall be operated by the professional at the time of the crash test. General can at the local special equipment inspection institutions detection, can also be tested in other qualified enterprises, such as: wuhan science, Shanghai special survey, qufu golden horse machinery testing!
Q:Can a construction elevator use a single cage
Seriously, a construction elevator in wuhan just happened, and 19 people died. Go and see!
Q:What are the requirements for the construction elevator
So for safety device factory test is very strict, before delivery by the statutory inspection unit for torque measurement, critical speed measurement, measuring the amount of spring compression, each with the test report, after assembly to the construction lifter for drop test under rated load, and the site to use the elevator must be every three months to conduct a drop test. For safety device to the factory for two years for safety device (delivery date), must also be sent to the statutory inspection unit to carry on the test, after testing once a year.
Q:The tower crane is on a surface with the construction elevator, and only 2 or 3 meters away. Is that allowed
Congratulations, it's a tragedy when you want to start the tower

1. Manufacturer Overview

Location 2006
Year Established Jiangxi,China
Annual Output Value US$5 Million - US$10 Million
Main Markets South America; East Asia; Southeast Asia; the Middle East; Africa
Company Certifications ISO 9000 ISO 9001

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port shanghai
Export Percentage
No.of Employees in Trade Department 3-5 People
Language Spoken: English
b)Factory Information  
Factory Size: 3,000-5,000 square meters
No. of Production Lines 3
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range High and/or Average