API Cast Steel Lift Check Valve 900 Class

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 pc
Supply Capability:
100 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

API Cast Steel Lift Check Valve 150 Class

The features of Cast Steel Lift Check Valve

Bolted Bonnet;Swing and lift disc;Metallic seating surfaces.

Body and Bonnet Connection of Cast Steel Lift Check Valve:

The body and bonnet of Class150~Class900 check valves are usually with studs and nuts.And the body and bonnet of Class1500~Class2500 check valves are usually of pressurized seal design.

Body-To-Bonnet Joint of Cast Steel Lift Check Valve:                                                                                                         

Stainless steel + flesible graphite wounded gasket is used for Class 150 and Class 300 check valve;Stainless steel + flexible graphite wounded gasket is used for Class 600 check valve,and joint gasket is also optional for Class 600 check valve;Ring joint gasket is used for Class900 check valve;Pressurized seal design is used for Class 1500~Class 2500 check valves.

Seat of Cast Steel Lift Check Valve:

For carbon steel check valve,the seat is usually forged steel.The sealing surface of the seat is spray welded with hard alloy specified by the customer.Renewable threaded seat is used for NPS<10 check="" valves="" and="" welded="" on="" seat="" can="" be="" also="" optional="" if="" being="" requested="" by="" the="" customer.welded="" is="" used="" for="" nps="">12 crbon steel gate valves .Forstainless steel check valve,integral seat is usually adopted ,or to weld hard alloy directly integrally.Threaded or welded on seat is also optional for stainless steel check valve if being requested by the customer.

Parameter of Cast Steel Check Valve:

Standard Criteria

 ASME/ANSI/API customize 

Pressure Rating

 150 Class  300   Class  600 Class  900 Class  1500   Class  2500 Class customize 

Valve Size

 50 mm  65   mm  80 mm  100 mm  125 mm  150   mm  200 mm  250 mm 300 mm  350   mm  400 mm  450 mm  500 mm  600   mm  650 mm  700 mm 750 mm

 2 inch  2.5   inch  3 inch  4 inch  5 inch  6   inch  8 inch  10 inch  12 inch 14   inch  16 inch  18 inch  20 inch  24   inch  26 inch  28 inch  30   inch customize 

Actuator

 Automatic customize 

Connection

 Butt Welding  Flange   RF  Flange RTJ customize 

1-Body Material

 A216   WCB  A351-CF8  A351-CF8M customize 

2-Seat ring

 A351-CF8  A351-CF8M  A105+13Cr  Tool   Steel+A105 customize 

3-Disc

 Tool Steel+A216 WCB  A351-CF8M  A351-CF8  A216   WCB+13Cr customize 

4-Arm

 A351-CF8  A216   WCB  A351-CF8M customize 

5-Nut

 A194   8M  A194-8  A194 2H customize 

6-Arm pin

 A182-F6a  A182-F316  A182-F304 customize   

7-Yoke

 A351-CF8  A351-CF8M  A216   WCB customize 

8-Bonnet nut

 A194   8M  A194-8  A194 2H customize 

9-Bonnet bolt

 A193-B8  A193-B8M  A193-B7 customize   

10-Bolt

 A193-B7  A193-B8  A193-B8M customize   

11-Gasket

 graphite+304  graphite+316 customize   

12-Bonnet

 A216   WCB  A351-CF8M  A351-CF8 customize 

13-Eye bolt

 A181 customize 

Design Standard

 API 6D  BS   1868 customize 

Connection Standard

 API 605  ASME B   16.25-2007  ASME B 16.47A  ASME B 16.47B  ASME   B 16.5  MSS SP-44 customize 

Test Standard

 API 598  API   6D customize 

Face to Face

 ASME B 16.10 customize   

Pressure-temperature ratings

 ASME B   16.34-2004 customize 

Wall thickness dimension

 API 600  BS 1868

 

FAQ of Cast Steel Check Valve:

Q1:I can’t find the type of steel check valve which I need. what can I do?

The chart above only lists out some common composition of steel check valve parts.We may provide other different parts material composition according to the customer's request or the actual valve working condition.

Q2:Which certification do your products pass?

  Our products are in accordance with ISO 9001ISO 14001API 6AAPI 6DTS CEAPI607/6FA/BS6755.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Leaking metal Tyre valve stem?
The leak is caused by corrosion of the alloy wheel in the hole that the metal valve stem goes through. You might try to let the air out and loosen the nut on the valve stem and spray penetrating oil on the o-ring which is on the base of the valve stem and is what holds the air in. Turn the stem back and forth a bit to mave the corrosion and then respray the o-ring. Tighten the stem nut, inflate the tire to 35 lbs. and spray a bit of soapy water on the stem to check for leaks. If it still leaks you will need to remove the tire and valve stem,clean the hole and surrounding area inside the rim and clean the valve stem and replace the o-ring. If the valve stem is a pressure sensor type for the tire air pressure monitoring system you may need to reprogram it. Only use plastic caps on the valve stem. Metal ones corrode on the stem and wreck them and never come off.
Q:What causes Emergency Valve on Boiler to Leak?
Not sure what you mean by an emergency run valve. Are you talking about a relief valve? This will have a tag on it showing the relief pressure and has a lever to flip to check. Or is it an isolation valve that is leaking from the stem? If this is the case they usually have a packing nut that can be simply tightened to stop it from leaking.
Q:Leaky Valve?
i dont know, but i have one to. once a doctor told me if it gets real bad they could fix it with laser. i was on medication but quit taking it , it made my heart rate too slow. i got mitral vale prolasp. i dont know if i spelled that rite.if you have a heart doc. i would ask him to ease your fear. good luck.
Q:Wall Heater question? (Gas Valve)?
Depends on what kind of wall heater. FOR A 24 volt system : you will need a ohm/volt meter to do that. Make sure the thermostat is calling for heat, and the gas going to the unit is on. you should have 24 volts at the gas valve. if there is 24 volts there, and the burners are not on, then the gas valve is bad. If you don't have 24 volts there, then your thermostat could be bad, and not turning on the gas valve, or you might not have control voltage. You should be familiar with basic electricity to do this.
Q:EGR Valve Circuit code P0403?
if your valve was carboned up then you Dp sensor is probably clogged as well and that would cause the light to come on and it would give that code. You can more than likely take it off and clean it really well with something like LPS or brake cleaner...carb cleaner would work also
Q:Is a leaky heart valve considered heart disease?
Hello, Yes, it is. Obviously the leak is still within the arteries, - no blood is leaking out of the heart, - any leak is only in the backwards direction of blood-flow. One function of the valves is to stop blood which has just been pumped, from falling backwards again to where it came from. As soon as the pumping action stops, the valve has to close to lock the pumped-blood in its new forward position. If any blood leaks back through the closed valve, that is called regurgitation of blood, - and the closed valve which is leaking is described as incompetent or insufficient, in medical language. Sometimes newborn babies are born with a heart valve (or valves) that leak backwards, having not been properly formed in the womb, - or sometimes the valve (or valves) are damaged in adult life by some disease, - for example, infections like Rheumatic Fever or Syphilis, (both rare nowadays). I hope this is of some help. Best wishes, Belliger retired uk gp
Q:Leaking car tyre valve?
you just need the valve itself changed...its nothing to do with the tyre as the valve is bolted to the wheel not the tyre...
Q:99 eclipse bent valve?
no way to tell ...and he doesn't sand down the valve ...it's called seating or lapping. and it's not done to the cylinder... knocking could aslo be a hung lifter.
Q:Who knows about pneumatic engine valves?
not really
Q:Wiring water Level Switch to Solenoid Valve?
From power, go to the float valve. From the other side of the float valve, go to your solenoid. From the other side of the solenoid, go to neutral return. When the float valve is open, the switch will be open, and the solenoid will be open. When the float rises and closes the switch, the current will flow closing the NO solenoid to engage and shut off your water flow.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range