Aluminum Concentric Cable 2*6 AWG PVC/XLPE insulation power cable

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
200 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

1.Al 2*6 AWG PVC/XLPE power cable
2.ISO TUV CCC
3. With Nuclear tech
4.National Enterprise Tech Center
5. 72.6-year-life

Aluminum Concentric Cable 2*6 AWG PVC/XLPE insulation power cable

Product Description

 

Constructions

Conductor

Compact Stranded Copper Conductor, Class 2 as per IEC 60228

Circular solid Copper Conductor, Class 1 as per IEC 60228

Flexible Stranded Copper Conductor, Class 5 as per IEC 60228

Insulation

Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)

Filler

Polypropylene filament with lapped binding tape

overall Screened

Copper wire

individually Screened

Copper wire

Filler

PP Yarn, or Paper

Wrapping Tape

PP

Inner Covering

Extruded PVC

Armour

Steel Tape

Overall Sheath

PVC

Applications

For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.

Standards

International: IEC 60502-2, IEC 60228 IEC 60840;IEC62067

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request

Technical data

Rated voltage: 0.6/1kV,

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

                   15 x cable O.D for single-core armoured cables

                    15 x cable O.D for multi-core non-armoured cables

                   12 x cable O.D for multi-core armoured cables

 

Certificates

TUV, RoHS, CCC, ISO 9000,ISO10004 and more others at request

Marking

According to the customers' requirements

Nominal cross-sectional areas

1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2.

Type

Designation

Applications

VV

YJV

VLV

YJLV

Copper conductor, PVC ,XLPE insulated, PVC sheathed power cable

Aluminium conductor, PVC ,XLPE  insulated, PVC sheathed power cable

For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct.

VY

YJY

VLY

YJLY

Copper conductor, PVC,XLPE insulated, PE sheathed power cable

Aluminium conductor, PVC ,XLPE insulated, PE sheathed power cable

VV22

YJV22

VLV22

YJLV22

Copper conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable

Aluminium conductor, PVC ,XLPE  insulated, steel tape armoured, PVC sheathed power cable

For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.

VV32

YJV32

VLV32

YJLV32

Copper conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable

Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable

For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large ulling force.

Note: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the installation specification for the cable tray bracket?
You ask the question is the installation of the trough or concealed it? If it is installed that is the first line and then drill the drill hole with the impact of drilling holes after the new material with a new material. If it is concealed there is no such problem that is buried pipe buried in the wall on the line
Q:Otocinclus eating heater power cable?
No problem, it's just scraping the algae off. Might get though the cable itself in couple of 100 years or so, so nothing to worry about. Ian
Q:Can I buy a 6 pin power cable and plug it in to the wall?
pair it with some external 4 pin converters but i would recomend just buying a proper psu
Q:Do ferrite beads on audio leads and power cables do anything meaning full?
Generally they are fitted to fix a narrow bandwidth issue, so you would need to know what interference issue you are trying to fix. In most coaxial application this is for the roll off between shielding types.
Q:Can anyone identify the type of this monitor power cable and where to purchase one?
blurry.. okorder.com/
Q:I need to know if i can use 550 watt power cables from my old amp to power my new 700 watt amp?
You can use them, but you won't get the most from your equipment. However, I don't think anyone will be able to tell the difference, it will be minuscule.
Q:Outlets loosing power after hitting lower leg with cable snake.?
Would I be right in thinking you sort of tripped on flexible metal conduit in which electric cables run and now the power is intermittent and trips the breaker? I would start by isolating the circuit so it is no longer live and checking the connections at each end of the cable run because any strain on the conduit could have tugged wires out of their terminals. I'd make sure that all the connections were tight and the wires properly anchored and also that each wire is in the correct terminal. I once made a mistake when replacing a socket outlet because the terminals in the new one were the exact opposite of the old one. Luckily, I found it straight away when I tested the circuit. If the connections all look good, I'd check the continuity along each of the cables. It is inconceivable that the cables inside the metal conduit were damaged as they should be continuous cable runs with no joins. The continuity test will tell you if any cable is no longer continuous, but I'd be very surprised as long as the original installation was done properly to code (or wiring regulations in the UK). Obviously, before you start checking the cables, you would unplug or disconnect everything that is connected to them. If the fault only happens when some sort of machine or appliance is connected, then it suggests the fault is with the appliance or machine and not the wiring. A 20 minute cycle of faults makes we wonder whether there is a fridge or a freezer connected the circuit. If so, I'd get it checked for faults and check that the power connection to it is correctly wired. I am not an electrician, just an experienced home owner, so please double check anything I've said. Good luck.
Q:Do I need a S/ATA power Cable ?
the cable is connected to your power supply - you don't get a separate cable with your hdd - usually those power cords have 2+ connectors so just see which one fits (one of them might already be connected to your dvd drive or w/e)
Q:Power and Ground Cables?
Here okorder.com... I have the 8 gauge Kicker amp kit and it is wonderful.
Q:Lighting wire, I do not know is it. The When to use BV1 * 2.5, when to use 2 * 2.5, when to use 3 * 2.5, when to use 4 * 2.5,
Why did not you take this time when you were installed or that it was only a detour

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range