Aluminium Oxide /Silicon Carbide/Zirconia Oxide Fiber Disc See Large R Image Aluminium Oxide

Ref Price:
Loading Port:
China main port
Payment Terms:
TT or LC
Min Order Qty:
25 m.t.
Supply Capability:
2000 m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

Fiber disc,used for grinding polishing metal,wood , marble,stone,NFmetals and cast iron.

The fiber discs have high surface removal rate,they are widely used on  a diverse range of machines and with a varity of hole patterns,its rigid-flexible moderate,sharp wear-resistant varieties and complete specification.

Installed in the electric or pneumatic hand-held angle grinder on the widely used in shipbuilding,automobile,bridge,building,light industry and other industries ,suitable for use on steel,stainless steel,metal,NF netals,wood,plastic,marble and cast iron,it has good points of toughness,sharpness and strong cutting and grinding capacity.

 

 1. Specification

(1) AA (Aluminum Oxide)

(2) CC (Silicon Carbide)

(3) ZA (Zirconium Alumina)

2. Dimension

- 4", 4.5", 5" , 6" , 7" , 8" , 9" (other size available)

3. Grit

16, 24, 30, 36, 40, 50, 80, 100, 120, 150, 180

4. Package

- 25pcs / inner box

5. Origin

- Made in CHINA

6. O.E.M. Producing Available

Packaging & Delivery

Packaging Details:50pieces per blister parking,100pieces one box,and 500 per carton.
Delivery Detail:20days after received the prepaid
Aluminium Oxide /Silicon Carbide/Zirconia Oxide Fiber Disc See Large R Image Aluminium Oxide


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What's the definition of fire endurance of the fire-resistant coating for steel structure?
1. Fire endurance. Conduct fire resistance test of any building component according to the standard time-temperature curve, and the time when it is subjected to the fire to the time when it loses support capability or fire insulation function or its integrality is destroyed is referred to fire endurance. 2. Steel has relatively low fire endurance which is usually 0.25h only, namely 15 minutes; 3. Of steel structure buildings, steel can be used as beams, pillars, etc. but its fire endurance is not enough (usually these components have higher requirement on fire endurance, and take pillar as an example, it is usually demanded that the fire endurance should be 2-3h), and under this condition, it needs to brush fire retardant coating so as to raise the fire endurance. As to the specific quantity or types of the fire retardant coating, it is decided upon the actual conditions. In short, the building material needs to meet the required fire endurance of the buildings.
Q:What are Grade-A waterproof inorganic thermal insulation materials?
Grade-A waterproof inorganic thermal insulation materials include: 1. external wall thermal insulation materials: (1) silicate thermal insulation material (2) gelatine powder polyphenyl granule (3) steel wire gauze picking cement cystosepiment (Estazolam plate) (4) extruded sheet; 2. roofing materials: (1) XPS Extruded sheet (2) EPS cystosepiment (3) perlite and perlite bricks (4) vermiculite brick; 3. heating and air conditioning material: PUR, rubberplastic sponge, polystyrene foam, glass wool, rock wool; 4. steel structure material: polystyrene, extruded board, polyurethane board, glass wool roll mat, etc.
Q:What are the requirements on fire resistance period of C-level fireproof glass?
It can be classified into three types in terms of fire resistance, Class A: The fireproof glass which meets demands of fire integrity and fire insulation at the same time. This glass has advantages of excellent transmittance, fire-proofing(smoke resistance, fire insulation, and blocking heat radiation), sound insulation and impact resistance. It can be applied to architectural ornaments, fire resistant timber doorsets with steel structure, windows, upper beam, partition walls, daylighting roofs, ceiling screens, perspective floor and other building components which need transparency and fireproofing. Class B: The fireproof glass which meets demands of fire integrity and thermal radiation intensity at the same time. This glass is mostly composite fireproof glass which has advantages of transmittance, fireproofing, and smoke resistance. Class C: The fireproof glass which only meets demand of fire integrity. This glass has advantages of transmittance, fireproofing, smoke resistance and high intensity. It can be applied to fireproof glass partition walls, fire windows and with no requirements on outdoor curtain walls, etc. The fireproof glass can be classified as composite fireproof glass and single chip fire-proof glass in terms of structure.
Q:Who can tell me what is neutral refractory?
Refractories mainly refer to aluminum oxide, chromium oxide and carbon as the main component of refractory materials, such as corundum brick, high alumina brick, and carbon brick. Its characteristic goes to the resistance to both acidic and basic slag. Basic refractories mainly refer to the refractory materials whose mian components are magnesium oxide and calcium oxide, including magnesia bricks, magnesia-alumina bricks, magnesia chrome bricks, dolomite bricks, etc. Basic refractory is good at resisting basic slag erosion.
Q:Who knows about the differences between 3M fireproofing materials and ShiLiDe materials?
Advertising materials can be divided into fireproofing and non-fireproofing ones which can not tell the differences with naked eyes. You can ask 3M to provide test reports or go to a the third party test organization SGS to do flame retardant test, maybe I can help you. Mineral wool board is harmful to human body, will lead to chronic poisoning, the quality of it is bad! You must pay attention to it! It can not be used in chemical and pharmaceutical plants.
Q:How to classify fire resistance rating of brick-concrete structure?
In order to ensure the safety of the building, the fire protection measures must be taken to make it have a certain degree of fire resistance, even if there is a fire, it will not cause too much damage. According to the national conditions of our country, and in the light of other countries standards, < high-rise civil building fire protection design specification > defines fireproof rank of high-rise civil buildings into level one and two; < code for fire protection design of buildings > divides the rank into level one, two, three, four, level one is the highest level, level four is the lowest. Besides that the minimum fire resistance of the building component is specified, buildings of fire resistance rating also specified requirements for combustion performance. Because the component with the same fire resistance limit is different, it is different in the fire.According to our country national standard < building design fire protection code >, the fire resistance rating of the building is divided into four levels. The fire resistance of a building is determined by the combustion performance and fire resistance of building components (such as beams, columns, floors, walls, etc.). Generally speaking, the fire resistance building of level one is a mixed structure of reinforced concrete structure or a mixture of brick wall and steel concrete structure; the fire resistance building of level two is a mixed structure of steel truss structure, reinforced concrete column and brick wall; the fire resistance building of level three is brick-wood structure made of wood roof and brick wall; the fire resistance building of level four is combustible structure which is composed of wood roof and non-combustible wall.
Q:The classification of clay according to refractoriness, and what is the plasticity and plasticity index of clay?
Q:What are the common refractory insulation cotton material?
I know less about this, I hope the following will help: Fire resistant thermal insulation material mainly refers to inorganic thermal insulation material and compround thermal insulation material. According to the shape can be divided into: Fibrous finishes, slag wool, rock wool, glass wool, aluminum silicate cotton. ceramic fiber, micro pile of diatomite, calcium silicate, expanded perlite, expanded vermiculite, aerated concrete etc., foam like bubble glass, volcanic ash glass, foam clay, foaming concrete, paste powder polystyrene particles insulation slurry
Q:The performance of refractory material
As for easticity modulus, you can serach for information on the Internet or specialized books.
Q:What are the grades of refractory exterior wall thermal insulation materials?
Classification of fire rating of extrior thermal insulation materials 1, According to national standard GB8624-97, the combustion performance of building materials are divided into the following grades A level: Incombustible building materials: Materials hardly burn. B1 class: Flame-retardant building materials: Flame-retardant material has good flame resistance. In case of fire in the air or at high temperature, it is difficult to catch fire and the fire will not spread quickly. And when the combustion source is removed, the burning will stop immediately. B2 Class: Combustible building materials: Combustible materials have a certain flame retardancy. In case of fire in the air or at high temperature, it will immediately burst into flames and it is easily to spread fire, such as wooden column, wooden roof truss, wooden beams and wooden stairs, etc. B3 level: Inflammable building materials: It has no flame retardant effect, and it is extremely inflammable, and the risk of fire is high. Classification of exterior wall thermal insulation materials according to fire rating: 1. Thermal insulation materials with A-level combustion performance Rock wool, glass wool, foam glass, foamed ceramic, foam cement, hole-closed perlite, etc. 2, Thermal insulation materials with B1-level combustion performance: Extruded polystyrene board (XPS) after special treatment / polyurethane (PU) after special treatment, phenolic aldehyde, gelatine powder polystyrene granule, and etc. 3. Thermal insulation materials with B2-level combustion performance: Molded polystyrene board (EPS), extruded polystyrene board (XPS), polyurethane (PU), polyethylene (PE), etc.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range