Aluminium Conductor PVC Insulated Electrical hdmi Cable

Ref Price:
Loading Port:
China main port
Payment Terms:
TT or LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Aluminium Conductor PVC Insulated Electrical hdmi Cable

 

Specifications

1 electrical hdmi cable
2 GB,IEC,AS,BS Standard, CE,ISO,SGS,CQC/ABC,CCC,SAA Approval
3 On time delivery
4 Professional QC                

                            

Copper conductor PVC insulated electrical hdmi cable

 

1) Standard :IEC60502,GB/T 12706

  

 

2).Voltage :0.6/1KV

 

Conductor: Solid or stranded Copper/Aluminum -Insulation: Cross-linked polyethylene( XLPE or PVC) -Filler: Polypropylene lament with lapped binding tape -Inner Sheath: Polyvinyl chloride (Black) -Armor: Galvanized steel wire/steel tape/Unarmored/Aluminum wire -Core-covering: Binding tape -Outer Sheath: Polyvinyl chloride (Black)

    

3).Specification:

 

Type

Designation

VV

Copper conductor ,PVC insulated ,PVC sheathed power cable

VLV

Aluminium conductor ,PVC insulated ,PVC sheathed power cable

VY

Copper conductor, PVC insulated, PE sheathed power cable

VLY

Aluminium conductor ,PVC insulated ,PE sheathed power cable

VV22

Copper conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable

VLV22

Aluminium conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable

VV23

Copper conductor ,PVC insualted ,steel tape armoured ,PE sheathed power cable

VLV23

Alunminium conductor ,PVC insulated ,steel tape armoured ,PE sheathed power cable

VV32

Copper conductor, PVC insulated, steel wire armoured,PVC insulated power cable

 

VLV32

Aluminium conductor, PVC insulated ,steel tape armoured ,PVC sheathed power cable

VV33

Copper conductor, PVC insulated steel wire armoured , PE sheathed power cable

VLV33

Aluminium conductor , PVC insulated , streel wire armoured ,PE sheathed power cable

 

4).nominal cross sectional areas: 1.5 mm2, 2.5 mm2 ,4 mm2, 6 mm2, 10 mm2 , 16 mm2,25 mm2 , 35 mm2, 50 mm2 ,70 mm2 , 95 mm2 ,120 mm2 ,150 mm2,185 mm2 , 240 mm2, 300 mm2  400 mm2 500 mm2 630 mm2 800 mm2

 

5)production range: single core cable from 1.5 mm2 to 800 mm2,muli-core cable from 1.5 mm2   to 400 mm2

 

6).operating characteristics:

 

Rated power-frequency voltage u0/u:0.6/1 KV

Max permissible continuous operating temperature of conductor 70

Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): cross-section of conductor  300 mm2

 

The anbient temperature under installations should not be below 0

 

The bending radius of single core cable should not be less than 20 times of the cable diameter ,the bending radius of multi-core cable should not be less than 15 times of the cable diameter

 

Picture

Aluminium Conductor PVC Insulated Electrical hdmi Cable

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Buy Taipower c 450P with remote control to add audio and video cable
Cable and cable distinction In fact, "wire" and "cable" and there is no strict boundaries
Q:Now the market professional installation monitoring the construction team how much money a point? , As well as cable patch panels and telephone patch panels how much money a point? Is it distance?
I think it is possible, because in our (old) substation, the cable trench is the drain, the cable erected in the cable bracket.
Q:What is the difference between a trunking and a bridge in a weak construction?
Power circuit box, the home of the circuit is divided into lighting, walls, air conditioning, etc., there is the bathroom and the kitchen line and the separation of the room.
Q:What is the difference between "wire" and "cable"?
Simple point, the plotter is generally used to out of the line map, the general is the Academy of Engineering, the Bureau of the use of a CAD map, and some can also be some effect of the general effect of the map, generally suitable for color requirements are not very high, but right Print accuracy requires a high place. Inkjet machine can be divided into indoor and outdoor ink, outdoor irritating smell, for outdoor advertising like the effect of the map, the indoor no irritating smell, the general subway, as well as other indoor advertising are used this out of
Q:Where should the inner diameter of the plastic tube of the cable be at least the number of times the outer diameter of the cable?
You are not very clear: how to start again? 300μF capacitor is normal? If the sound is normal (very small) after no-load start, the cable and the motor temperature are normal, the coil can be judged to be normal
Q:Wire printed on the word what way to erase
Wipe with water that day. You can also use ink thinner
Q:What kind of KVM switch is this configuration below?
Hello according to your request can be used two sets of ordinary 16 cascade, to a control terminal control 32 hosts. Is the cheapest solution. According to my understanding of the domestic Haikang series of products cost-effective, you can understand the next.
Q:Home leaked, installed in the floor below the wire was blisters will have any security risks? How can the water inside the pipe to dry
Megohmmeter, such as measuring insulation normal, that is, induction power, the other line after grounding, the pen measured no electricity.
Q:Seeking the basement of the outer wall piercing the cable after the casing, how to solve the water (200 points online)
Line width, and can not pass the gap between the chip pins, even after, but also because the distance between the wire and the lead is less than the electrical rules specified in the safe distance. In general, the ground can not pass through the gap between the chip pins, go outside or take the gap between the two columns through the gap. The width of the ground wire can also be set appropriately, and the wire is widened by adding a polygon brass cut. The safety distance in the electrical rules defaults to 10 mils, which is relatively small, and the safety distance of the different networks should be set separately as needed.
Q:What does the letter of the computer cable model mean?
The meaning of the letter: W refers to the halogen-free, D refers to the low smoke, Z refers to the flame retardant WDZ is halogen-free low smoke flame retardant jacket power cable. WDZC refers to halogen-free low smoke C-class flame retardant

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range