Product Description:

Usage of Calcined bauxite
1.Aluminium industry.

2.Precision casting.

3.Refractory industry.

4.Silicic acid aluminium firefibre

5.Mixed with magnesium oxide,it can be an nice bonding agent,especially for pouring entire steel teeming ladle lining

6.Manufacture bauxite cement,grinding abrasives.ceracmic industry,and chemical industry for making aluminium compounds

Packaging & Delivery

Packaging Details:within 15 days after receiving L/C or Payment
Delivery Detail:Packing in 25kg bag or 1mt big bag

Specifications

Bauxite 
1 Al2O3:>=85% 
2 Fe2O3:<=2.0% 
3.Bulk Density:>=3.0g/cm3 
5. refractory/welding industry

 AL2O3 85%min China Calcined Bauxite Manufacture

 

1. Calcined bauxite 
AL2O3:70% min.
FE2O3:2% max.
SIZE: 1-5MM 90% min.

china calcined bauxite manufacturer since 1999 
purity of al2o3 75%-90% 
rotary kiln calcined bauxite 
self-owned bauxite mines

 

 

Specifications of Calcined bauxite

 

Grade

AL2O3

SIO2

FE2O3

TIO2

K2O+Na2O

CaO+MgO

Bulk density

HX75

75min

≤17

≤3.0

≤4.0

≤0.3

≤0.5

≥2.70

HX80

80min

≤12

≤3.0

≤4.0

≤0.3

≤0.5

≥2.80

HX85

85min

≤8

≤2

≤4.0

≤0.3

≤0.5

≥3.00

HX86

86min

≤7

≤2

≤4.0

≤0.3

≤0.5

≥3.10

HX87

87min

≤6

≤2

≤4.0

≤0.3

≤0.5

≥3.20

HX88

88min

≤5

≤1.8

≤4.0

≤0.25

≤0.5

≥3.25

HX90

90min

≤3

≤1.8

≤4.0

≤0.25

≤0.5

 ≥3.3

Moisture(max)

0.50%

 

Size of Calcined bauxite

Section sand:0-0.3mm,0-0.5mm,0-1mm,1-3mm,3-5mm,5-8mm.

Fine powder:100#-0,200#-0,325#-0

Moh’s hardness: 7-8

Melting point:1770-2000 C


AL2O3 85%min China Calcined  Bauxite  Manufacture


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Does anyone know about the fire resistance period of thin fireproof coatings?
The columns are 2.5 to 3.0 hours, beams are 2.5 hours, C-shaped steels are 0.5 hours. The thin steelwork fireproof coatings are primarily water-soluble, which will be expanded and foamed when exposing to the fire. Thus the fire-resistant insulation layer formed through expansion and foaming will delay the temperature increase of the steel and protect of steel components. The thin fireproof coatings are made of adhesives, catalysts, carburizers, foamers, fillers, fibers and modifiers. The required emulsion polymers must have good adhesion, durability, and water-resistance to the steel substrates. The coating has a strong adhesion and good flexibility, is light and thin, as well as highly resistant to vibration. It is especially applicable for indoor bareness steel structure, light layer steel structure, and steel structure with decoration demands whose fire resistance requirement is within 1.5-2.5 hours.
Q:Refractory material, refractory brick
Refractory materials of various varieties, different uses, it is necessary to scientifically classify refractory materials, so as to facilitate scientific research, rational selection and management. There are many classification methods for refractory materials, among which chemical properties classification method, chemical mineral classification method, production technology classification method, material form classification method and so on are included.
Q:Can refractory be used as sealing element?
It can. For example, a kind of irregular part that is made of fiber or some injection mix is used for sealing things.
Q:Who knows the external wall thermal insulation materials fire rating requirements?
The requirements of Department of Housing and the Ministry of Public Security No. 46: Residential buildings: the height of building is greater than 100 meters, the combustion performance of insulation materials should be level A. The other civil buildings: 24≤ height
Q:How about the prospect of refractory material?
Due to the rise of raw material, the prospect is not good with inflation, lower prices and decreased profits. The product requirements have been enhanced and there is vicious competition. Therefore, it is really bad.
Q:How many fire endurance grades are the AAA fire resisting shutter divided?
The fire shutter is divided into A / B / C classes. The refractory limits are not less than 1.2 /0.9 /0.6 hours. References to "general technical specification for steel fire resistance rolling shutter door GB 14102-93". 4.3 4.3.1 Classification according to fire resistance time. The common steel fire resisting shutter(see Table 3) The categories of the codes of the refractory time hF1 1.5F2 2.04.3.2 composite steel fire shutter composite steel fire shutter(see Table 4). Table 4 and Category Code refractory time hF3 2.5F4 3.04.4 refractory press time, smoke performance classification 4.4.1 ordinary steel fire anti-cigarette curtain (see Table 5) Table 5 and category code leak smoke refractory time h (20Pa pressure) FY1 1.5 ≤0.2m3 / m minFY2 2.0 ≤0.2m3 / m min4.4.2 composite steel fire anti-cigarette curtain (see table 6) table 6 and category code leak smoke refractory time h (20Pa pressure) FY3 2.5 ≤0.2m3 / m minFY4 3.0 ≤0.2m3 / m min excerpt complete fire shutter when the fire district for fire resistance of 3 hours, the opening portion on the firewall setting fire shutter fire resistance of 1.2 hours. **** Fire resistance of 3.0 hours called premium (fire back surface). "Construction Regulation" is mentioned in setting up a firewall and used as the separation of the fire resisting shutter and the fire compartments. When taking the fire back surface temperature rise as the fire resistance standard of the fire resisting shutter, the fire endurance should not be less than 3.00h; When taking the fire back surface temperature rise as the fire resistance standard of the fire resisting shutter, the two sides of the roll should have protection of  closed automatic water spray system, and the duration of water spray system should not less than 3.00h. In summary: The fire resisting shutter can be divided into: Grade, A, B and C looking to adopt
Q:The classification of fire-resistant material
Refractory material cna be divided into common and special fire proofing material. Common fire proofing material can be sub-divided in to acid fire proofing material, neutral fire proofing material. and alkaline fire proofing material according to chemical properties. Special fire proofing material can be divided into high temperature oxide refractory, refractory compounds and high temperature composite materials according to the composition. In addition, it also can be divided into common refractory products (1580 ~ 1770 ℃), high-grade refractory products (1770 ~ 1770 ℃) and super refractory products (above 2000 ℃) according to the strength . According to the shape, it can be divided into block (standard brick, special-shaped brick, etc.), special shape (crucible, sagger, pipe, etc.), fibrous (aluminum silicate, zirconia and boron carbide, etc.) and irregular shape (refractory clay, refractory castable, ramming material and so on). According to sintering process, it can be divided into sintered product, fused cast product and melting jetting product.
Q:Who can introduce the external wall thermal insulation materials fire rating regulations?
According to public fire-fighting [2007] No. 182, the contents of the notification on the implementation of a number of issues of national standards GB8624-2006 "building materials and products combustion performance classification", since there is large differences between the new version of the standard GB8624-2006 and the old version of GB8624-1997 in the principle, hierarchical structure and test methods. According to the cintent of notification, in order to ensure a smooth transition between the old and new standards, the current national standard "Fireproof  Specification of Building Interior Decoration Design" GB50222, "fire safety rules of tall civil buildings design" GB50045, "Fireproof  Specification of Building Design" GB50016 have not completed the relevant amendments, the new classification method of GB8624-1997 and GB8624-2006 can be used for temporary reference in terms of combustion performance of materials . From GB8624-2006 standard implementation, the classification of combustion performance is too granular, which do not match to the actual construction of the current project in our country. Therefore, the relevant departments carry on the 3rd amendment for the GB8624-2006 standards, namely GB8624-2012, and it will be released on December 31, 2012 and implemented on October 1, 2013. The combustion grading requirements in the standard: Level A is non-combustible materials (products); level B1 is nonflammable material (products); level B2 is combustible materials (products); level B3 is flammable materials (products).
Q:How many types do refractory bricks have? Where the quality of refractory material is best? What is the model?
Sinosteel Luoyang (Luoyang Refractory Material Plant in the past): High alumina(mainly blast furnace), Gongyi. There are also a series of high-tech materials (silicon carbide, carborundum, etc.) a major producer of high alumina; silicious: Resistant material for steel, glass furnace, cement kiln); magnesia. Divide from uses and divide from chemical texture; silicious(glass furnace): Xinmi, Hennan Province, Lengshui River, coke oven, etc.). As for the models, Yixing and Changxing in Jiangsu Province: Haicheng, Liaoning Province; silicious, I do not understand your intentions; magnesia (nonferrous, steel refining; magnesia: High alumina brick; Dashiqiao area! Please put it in detail.
Q:How many levels are there in the classification of PP fireproof materials?
The level of fireproof materials: A-level: Non-combustible building materials have rare chance to burn. A1-level: Non-combustible materials, no open fire A2-level: Non-combustible materials, smoke should be tested and qualified. B1-level: Fire-retardant building materials: Fire-retardant materials are good at resisting flame. It is difficult for them to burst into fire when coming across open fire in the air or at high temperature. It will not quickly get wilder and when the fire source removes, it will be extinguished immediately. B2-level: Combustible building materials: Combustible building materials can play a certain role in preventing combustion. It will immediately burst into flames when coming across open fire or at high temperature, and will lead to fire spreading, such as wooden pillars, roof frames and beams as well as stairs. B3-level: Inflammable building materials are highly flammable with no flame retardant ability, fire risk is high.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range