Al/Cu Conductor, PVC/PE/XLPE Cable,ABC,ACSR,AAC,AAAC,Control Cable/Aerial, Mining Cable, UL

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

LV&MV, Al/Cu Conductor, Insulation/Sheath PVC/PE/XLPE, Shield CTS/, Armour SWA/DSTA/ATA, Power/ABC/ACSR/Control/Overhead cable

 

Power cable

 

1. Material: Cooper, Aluminum

 

2. Rated voltage: low and medium voltage 

 

3. Wire identification: Red, yellow, blue, white, black

 

4. No. Of cores : Single core cable: from 1.5 mm2  to 800 mm2; Multi-core cable: from 1.5 mm2 to 400 mm2

 

5. Standard:   Low voltage: IEC60502-1 Medium voltage :IEC60502-2 or other requirement.

 

6. Insulation: PVC, XLPE, PE

 

7. Sheath:PVC, PE, XLPE 

 

8. Armor:   Galvanized steel wires armouror Galvanized steel tape armour Aluminium Tape Armour/ Aluminium Wire Armour.

 

9. Application: Suitable for indoor, channel, conduit,underground,vertical well etc.

 

10. Nominal cross section area: from 1.5 mm2 to 800 mm2.

Aerial Bundle Cable Service Drop

 

 1. 3x35+54.6+16  3x50+54.6+16  3x70+54.6+16 3x95+70+16  3x120+70+16 3x150+70+16 mm2

 

 2.2x16mm2 2x25mm2 2x35mm2 2x50mm2 4x16mm2 4x25mm2 4x35mm2

 

3. Standard: ASTM ANSI, ICEA S-76-474, NFC 33-209 or other request.

Overhead electrical stranded cable (Bare Conductor)

 

1.Material: 1) Aluminum stranded wire and aluminum alloy stranded wire 2) Overhead stranded galvanized steel wire 3) Aluminum clad steel

 

2. Type: AAC, AAAC, ACSR, ACAR.

 

3. Standard:  AAC: GB/T 1179-2008 IEC 61089 ASTM B232 BS 215 part1, DIN 48201-5 or other requirement.

 

AAAC:GB/T 1179-2008,  IEC 61089, ASTM B 399   BS3242, DIN 48201-6 or other request.

 

ACSR : GB/T 1179-2008,  IEC 61089,  DIN48204,  ASTM B232,  BS215 PART 2or other request.

 

  

4.Application: These cables most widely used aerial line in aerial electric transmission lines and main product to form a power grid.

FAQ:

  1. Where is the place of rigin?

    Beijing, China.

  2. What is the materials of the conductor?

    Alumina or Copper.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why this cable has not yet been certified
The manufacture of wire and cable is completely different from that of most electromechanical products
Q:A five-hole dual-socket how to connect the wiring, the electrician line to go three lines, the switch can use a single socket did not take their own hands
Bookstore tool book should have "communication project budget", I do is what you say, the budget is divided into estimates and budget, is two steps. So that is not very clear. But what is needed is the preliminary design of the project. The budget is needed for design and drawings. Internal management of this piece, the main thing is that you need to do what the project department, and are generally very complicated
Q:Fiber optic cable split box, integrated wiring box, cable terminal box, cable transfer box difference
KVV is the control cable, generally do industrial control; and RVS is twisted pair, generally used for weak system, to eliminate the interference requirements of the occasion, such as two-wire bus system, specifically, the electrical fire bus more Such as RS485 bus and so on.
Q:Wire pipe inlet air switch trip how to do?
Put the water clean, with a table to measure the insulation resistance between the lines, as long as no less than 1.5-2 can.
Q:Help look at such a configuration will not have compatibility issues! Do you need to improve? Budget in 5500 or so
What do you want to do? Do network cabling buried? Or in the building after the tube?
Q:Wire printed on the word what way to erase
If you need an unqualified wire, you can contact this part
Q:Cable YJV-3 * 70 + 2 * 35 general wear large SC tube? Ask you.
Yes, it is more conducive to the protection of the battery, but if no power out of power, the data can not be saved ah, and you have to put the battery on a regular charge
Q:What is the difference between a trunking and a bridge in a weak construction?
Mainly to distinguish the ground which is the ground, the color of the ground is generally yellow-green; wire two is the fire line L and zero line N, no ground wire, look at the plug on the LN mark, the corresponding good.
Q:How are various wire and cable models named?
Cable type a lot, here to give an example: ZRC-YJV22-0.6 / 1KV3 * 25 +2 * 16 This model specification means: C-class flame retardant (ZRC) XLPE insulated (YJ) PVC jacket 22) steel tape armor (0.6 / 1KV) 0.6 / 1 kV (3 * 25) 3 25 square (+ 1 * 16) plus two 16 square copper conductor flame retardant copper core steel tape armored cross-linked poly Ethylene insulated PVC sheathed low voltage electric power.
Q:Home leaked, installed in the floor below the wire was blisters will have any security risks? How can the water inside the pipe to dry
casing filled with dry cement, and with a wooden hammer tamping, but a certain idea of security, high pressure line once rammed the skin is too dangerous, should be done before power, you now estimated to have power,

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range