• Air Evacuation Valve with Solar Water Heater Exhaust Valves of Solar Water Heater Parts on Sale System 1
  • Air Evacuation Valve with Solar Water Heater Exhaust Valves of Solar Water Heater Parts on Sale System 2
  • Air Evacuation Valve with Solar Water Heater Exhaust Valves of Solar Water Heater Parts on Sale System 3
Air Evacuation Valve with Solar Water Heater Exhaust Valves of Solar Water Heater Parts on Sale

Air Evacuation Valve with Solar Water Heater Exhaust Valves of Solar Water Heater Parts on Sale

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 pc
Supply Capability:
1000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

1.Packaging & Delivery

Packaging Detail:

standard export packing, steel pallets, wooden pallets, customers required

Delivery Detail:

10 Days

 Air Evacuation Valve  Specifications

1. good structure
2. pressure and impact
3. stability performance

Air Evacuation Valve Status: when the pressure is lower than the Standard Atmospheric Pressure in the ash silo, it generates vacuum in the silo. Then the film works and adjusts the air pressure back into the safety range.   

2.Product Introduction 

Air Evacuation Valve (So-called Ash Silo Relief Valve or Ash Silo Vacuum Relief Valve): is mainly used on the top of the Steel Silo or Ash Silo to release the extra pressure so that it will stay at a safe range all the time. Vacuum Relief Valve is made up of lid, spring ring, movable ring, film, spring of the retainer ring, retainer  ring, valve lid, Valve base. 

 Air Evacuation Valve is considered as a must-have facility for the ash silo.The pressure may change when the air stream inflows the ash silo or outflows, or the temperature rises or reduces. Release Valve protects the silo from safety hazard

3.Working Principle 

 1.Static status: Once you set up a pressure range. Normally,  pressuer could be maintained at a stable level in the ash silo.The valve lid keeps static, and the whole valve is completely sealed.

2.Pressure-Release Status: when the pressure rises upon the setted range, the valve lid would be opened automatically to release the extra airstream.As the pressure goes down to the standard level, the valve lid would be closed automatically.

 3.Vacuum-Released Status: when the pressure is lower than the Standard Atmospheric Pressure in the ash silo, it generates vacuum in the silo.Then the film works and adjusts the air pressure back into the safety range.So that, Relief Valve protects the silo from safety hazard.

4.Features

1. Customized is allowed.
2. Installing in welding or bolts.
3. Factory price.
4. Stock any time.
5. Positive rating:100%.
6. Neccessary device in storage silo.

5.Our Services

Private Customized:

We design  different Pressure Relief Valve according to specific requirement.

Customers’ Guidance:

Please leave the following info in inquiry

1.  What’s the raw material  ( carbon steel or stainless steel  )

2. What’s the entrance diameter( 508 mm /273 mm  or customized)

Because with these factors, we are able to give you a fast answer.

 

Air Evacuation Valve with Solar Water Heater Exhaust Valves of Solar Water Heater Parts on Sale

Air Evacuation Valve with Solar Water Heater Exhaust Valves of Solar Water Heater Parts on Sale

Air Evacuation Valve with Solar Water Heater Exhaust Valves of Solar Water Heater Parts on Sale

 

Q:G what's the meaning of the valve?
G is the diaphragm valve, valve type code, there are other types of valve code.A D is a safety valve, butterfly valve, check valve (H valve), J is the cut-off valve, throttle valve is L, P is Q is the drain valve, ball valve, S trap, U X is a plunger valve, plug valve, Y valve, Z valve.
Q:Excuse me American Standard pressure test valve GB standards are much ~ is how much valve pressure can play much pressure? Thank you
The standard is different, the test is not the same, what kind of valve you, a domestic valve only do stress testing, in fact, the pressure can generally be guaranteed, many are bad at high temperature or life testing above
Q:Tell me the exact address, or the phone number in the market. Where is the industrial zone (the valve) in Hefei? Please help, thank you
At the intersection of Mingguang Road and Shengli Road, the southwest side is all made of valves
Q:Which brand of electric valve is good?
Electric valve does not need to use imported, domestic boutique can meet.
Q:How about the quality of FITOK valves?
The United States fitok valve is the main valve and needle valve, globe valve instrument and meter tube also do.The quality of foreign valves are still good. Everyone thinks French valves are better than American ones. But the price is not cheap
Q:What is the difference between valve j941H-40 and j41H-40?
I see "valve design manual" category code table, in front of 9 of the electric drive, no 9 is the ordinary hand wheel drive.
Q:What valve is the YQZ45X-16Q?
Specifically, YQ usually is the enterprise code, Z valve, 4 representative flange, 5 representatives of the dark bar, X (soft) rubber seal (gate coated with rubber material), nominal pressure 16 representative (PN) 1.6Mpa, Q on behalf of the valve body is made of ductile cast iron. If you add the valve bore (DN), it will be more detailed.
Q:How to better maintain the valve?
How to maintain the valve?Enter the same as other mechanical products, but also the need for maintenance. This work well, can extend the service life of the valve, the following will introduce the valve maintenanceStorage and maintenanceThe maintenance of the purpose is to keep the valve in the custody of the damage, or lower quality. In fact, improper storage is one of the important reasons for valve damageThe valve custody, should be arranged in good order, a small valve on the shelves, large valves can be neatly arranged in the warehouse on the ground, not arbitrary lumber pile, do not let the flange face contact with the ground. This is not only for beauty, mainly to protect the valve, not to touch badBecause the storage and handling properly, hand wheel broken, crooked stem touch the fixed nut hand wheel and stem loosening loss and so on, these should avoid unnecessary losses.We temporarily on the short-term use of the valve, should remove the asbestos packing, in order to avoid electrochemical corrosion damage to the valve stem.I just entered the library on the valve, to conduct inspections, such as during transport into the water or dirt to wipe clean, re storedThe import and export of valves to use wax paper or plastic sheet sealed to prevent dirt insideThe valves on the machined surface rust in the atmosphere should be coated with anti rust oil, protectI placed outside the valve, must be covered with linoleum or tarpaulins like rain, dust items. Keep the storage of the valve clean and dry
Q:Why is copper used in cryogenic valves?
The rigidity of copper is better, and the friction parts are not easy to produce adhesion. The influence of temperature on copper is smaller than that of steel. Especially in the valve stem, there is also the important gear part, copper!
Q:What does valve J41H-16C mean?
J- stop valve4- flange type connection1- structure typeH- alloy steel seal16- nominal pressure 16 kgC- body carbon steel

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products