Air Conditioner Wall Mounted Split 18000BTU CS-12H/B1

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
20 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Condition:

New

Brand Name:

CNBM

Place of Origin:

Jiangsu China (Mainland)

Use:

Room

Power Source:

Electrical

Power Type:

AC

Type:

Split Wall Mounted Air Conditioners

Cooling/Heating:

Cooling/Heating

Certification:

CB,CE,EMC,RoHS

Capacity (btu):

18000

COP:

2.8

EER:

2.8

Power (W):

1900

Voltage (V):

220

Model Number:

CS-12H/B1

Pipe Size:

1/4" + 1/2"

Outdoor Size:

760x259x537

Indoor Size:

900x211x285

Condenser:

Pure Copper

Connecting Pipe:

Pure Copper

Cable:

3m

Compressor type:

Rotary

Loading Quantity:

230sets (40HQ)

Application Area:

20-35m2

Packaging & Delivery

Packaging Detail:Carton Box Packing
Delivery Detail:30-45 days after receiving down payment

Specifications

Wall mounted air conditioner :
1, R22/R410a
2, 18000BTU ;
3, Cooling only/Cooling& Heating ;
4, 220V 50HZ/60Hz.

 Wall Mounted Split Air Conditioner 12000BTU

1) Reliable quality---professional assembling and sufficient test, defective rate below 0.05%.

2) High quality compressors and parts with guarantee;.

3) Delivery: Within 45days after confirming the L/C or T/T swift copy.

4) Certificate--- CE, RHOS,MEPS, SAA, C-TICK, EMC, BV, SGS, ISO9001,SAA,CB, etc..

5) Compressor Brand: CHUNLAN, TOSHIBA, RCHI

6) 1% free parts of the total FOB amount.

7)OEM service.

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Air conditioning general how long does it take to add fluoride?
When using air conditioning, clearly feel air conditioning refrigeration result is bad, could be fluorine, the insufficient, need to add fluoride, but not air conditioning refrigeration result is bad must need to add fluoride to solve it, may be other reasons. 1: outdoor parts may be too dirty, dust is too thick, impact machine cooling, caused the result is bad, we in the actual repair often encounter this situation, 2: may be in the machine filter serious congestion, lead to machine evaporator in love can't normal circulation, and no wind blew out. 3: may be a blockage, air conditioning system caused by poor circulation, lead to air conditioning refrigeration and heating effect is not good. In general, can eliminate the above three conditions, the air conditioning will have to add fluoride, can work normally. Don't calculate by time
Q:VRV aircon exactly? And what's the difference between general central air conditioning?
VRV aircon system is in the electric air conditioning system, refrigerant compressor control through the cycle and enter indoor heat exchanger refrigerant flow, timely meet the requirements of indoor cooling and heat load of high efficiency cooling air conditioning system. Its working principle is: by the control system of collection and indoor thermal comfort parameters, outdoor environment and characterization of state parameters of refrigeration system operation condition, according to the rule of system operation optimization and the rule of the human body comfort, through frequency conversion and other means to adjust the compressor capacity, and control the fan of air conditioning system, electronic expansion valve and so on all control components, guarantee the indoor environment of comfort, stability and make the air conditioning system work in the best working state. VRV aircon system has obvious effect of energy saving, comfortable, the system on the basis of indoor load, continuous operation under different rotational speed, reduce the energy loss caused by frequent compressor start-stop; The compressor frequency startup, reduces the starting current, energy saving, electrical equipment will greatly at the same time to avoid the impact to other electrical equipment and power grids; Can adjust the capacity of characteristics so as to improve the indoor thermal comfort. VRV aircon system design and arrangement of the easy installation, flexible, architectural space is small, easy to use, high reliability, low operating cost, without machine room, no water system, etc. Central air conditioning: suitable for villas, room more units to use, every room need refrigeration, is relatively economic.
Q:The snow kind of what kind of air conditioning, they each have what effect
R401AR410A composed of two kinds of quasi azeotropic mixture, mainly include hydrogen, fluorine and carbon (HFC), has the stability, non-toxic, superior performance, etc.
Q:Air conditioning use how long and snow?
If it is newly bought 1 year commonly ~ but want to see you the last time I added many generalisations
Q:How to choose according to the size of air-conditioning P number?
Advocate lie 2 P, other 1.5 P My house advocate lie more than 20 is 2.5 P, covers an area of more than 10 1.5 P, 1 P effect is not good, 2 P is too cold Hope useful ~ ~ Don't care about sits up, open air conditioning, not air conditioning is hot, is closed the window, it doesn't matter
Q:Do you need frequency conversion for household air-conditioning
Children, older people with frequency conversion air conditioning good points, not a cold wind blowing out hot, it's not that easy to catch a cold and a headache.
Q:Household air conditioner purchase plan
30 flat is generally a square is 200 w, 6000 w. Sitting room + restaurants are better than one to add to the 250 w, 7500 w. 2500 = 1 p, 3 p.
Q:Which band air-conditioning energy efficiency is best
Air conditioning is level 3, or are a power hog.Now few, generally is secondary.
Q:How much is the two horses, home air conditioning?
When refrigeration rated running current around 7 a, heating, electric heating, electric current more than 10 a.
Q:Why didn't air conditioning dehumidification function?
Hot weather, air and humid, air conditioning refrigeration, dehumidification and wet air into the air conditioning, access to the condenser, formation water, flow to the outdoor, dehumidification. And the cold air temperature and the temperature of the condenser, unable to condense into water, so cold weather can't dehumidify. The theory is: air cooled to form water. The cold air meet more cold than it, how is it possible to form a water?

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range