  • Place of Origin: China (Mainland)

  • Model Number: AH

  • Condition: New

  • color: as request

  • material: high chromium A05

  • weight: 2-3 tons per pcs

  • inlet/outlet: 2" to 12"

  • assembly: electrical motor or diesel engine

Packaging & Delivery

Packaging Details:standard export plywood case
Delivery Detail:depends on the quantity.quick delivery and best service

Specifications

Complete model,
reliable manufacturer,
durable used,
do best custom-made service,
easy setting

slurry pump for Mining Process

LWA Type solids-handling centrifugal pump is designed for abrasive solids applications such as those found in aggregate, cement, lime slurries and many other common industrial and mining applications. Exclusive design features increase product versatility, improve pump reliability and lower energy consumption.

 

Markets

  • Cement & Aggregate

  • Industrial minerals

  • Mineral Processing

  • Waste Water

Applications

  • Cyclone and screen feed

  • Cement kiln feed and transfer applications

  • Thickener under/over flow

  • Tailings

  • Transfer applications

  • Loading/unloading applications

 

Capacity (m³/h)) Head (m) Speed (r/min) Inlet (mm) Outlet (mm)
 3.6-1209 5-99.4  350-3800 38-254 25-203

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why should the water inlet of water pump be fitted with reducer?
Increasing the pipe diameter can reduce the resistance loss along the path and reduce the suction vacuum of the pump! Before the inlet of the pump is a big diameter, when you reach the suction port, and the pump inlet diameter to be consistent, so the use of reducer joints!
Q:Water pump 50HZ impeller and 60HZ what is different, why not the same?
60Hz pump and 50Hz pump itself is not much difference, just that the motor speed, the rated speed is 3600 rpm, 1200 rpm, 1800 rpm, the latter is generally 3000, 1500, 1000 etc.. If it is to use the same pump, the difference is that the 60Hz motor pump flow is 50Hz, motor water pump flow of 1.2 times, the lift is 1.2*1.2=1.44 times, power is 1.2*1.2*1.2=1.728 times. So in the actual manufacture, especially some relatively large flow lift pumps, pump motor using 60Hz to use 50Hz thicker than the spindle motor of the pump impeller, the difference between the two, in addition to empty size shaft is different, what basically no difference. As for the data of package angle, the water conservancy models of different factories are different, but I don't know whether there is any difference between them. Most of them make no difference. However, if you want to use the 60Hz pump to achieve the same flow rate as the 50Hz pump, the impeller of the former should be cut to 0.833 times the size of the latter.
Q:55KW how large is the water pump wiring?
The general centrifugal pump is a three-phase squirrel cage asynchronous motor with a power factor of 0.85I=P/U/1.732/COS=55KW/380V/1.732/0.85=98.3A, light load, such as the use of YJV cable, ZR-YJV-0.6/1, 3*35mm2 copper core cable can be, such as heavy load or select VV cable, the cross-sectional area should be extended to 3*50mm2
Q:The pump assembly and the pump are not a thing
The pump assembly and the pump are the same, just name different, as all the car parts are called assembly, the pump is the same, called water pump assembly. Also, the pump half assembly is the water pump head.A pump is a machine that transports liquids or pumps liquids. It will be the prime mover of the mechanical energy or other external energy transfer to the liquid, the liquid energy increase, mainly used to transport liquids including water, oil, alkali liquid, emulsion, suspension emulsion and liquid metal, but also transport liquid, gas mixtures and liquids containing suspended solids. Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.
Q:4--6 inch deep well pump head? How much per hour out of water?.
General agricultural pump 4-6 inches of lift at about 20 meters, the economic output of water is 140-200 cubic meters per hour
Q:What is the function of the pump?
Drainage or irrigation
Q:What is the difference between a low pressure pump and a high pressure pump?
High pressure pump head, large power! High pressure pump, low pressure pump has no strict limit
Q:Pump frequent start will reduce the service life, I ask what kind of frequency is called frequent start?
How to define this frequently, this can only say, for example, the life of the switch is 60 thousand times, once every hour you move, it can be used for a long time, and that if you move one minute, it would not necessarily for long.Pumps frequently start the first self wear problems, as well as the impact on the pipe network, especially the soft connections.Water pump if the frequency of use or time, it is recommended to adopt: variable frequency constant pressure control.
Q:90kw pump star delta start, in the end to use the circuit breaker, AC contactor (Star contactor, angle contactor), what kind of thermal relay?
The star delta circuit you give belongs to the international standard starting mode, different from the old gb. The first said (the old national standard, is actually the domestic elders step-down manner, they are the main contactor) after shunt implementation of star triangle, so there will be a larger contactor, down economic calculation.And the new international standard (you give the circuit diagram) can be seen that the air switch to select the motor current to meet the given amount of surplus, 90kw motor rated current 175A, so choose 225A air switch can be. 1KM 2KM is the main operation of contactors, contactor, they each pay half the current line in triangle, so choose 110A (like never seen 100A) current, 3KM star, because of short-time current will not cause damage to the contact, a little lower 80A is not affected. Heat meter: if you don't use a transformer, you can choose JR36---160A.Some friends may feel small, in fact as long as you pay attention, you will find a lot of electrical equipment factory are doing this standard. In this way, both cost savings and service requirements are met.
Q:What is the difference between a sewage pump and a clean water pump? Why can't sewage be pumped with clean water?
The clean water pump and the sewage pump are different from the design. It also requires different material. Sewage pump requires material of solid phase friction, acid and alkali corrosion resistance, and other high resistance, and clean water pump can ignore these requirements. In addition, the sewage pump in a large proportion of large solids content of the fluid can also work normally, and clean water pump in the design can not meet the long-term use of this environment requirements.Of course, clean water pump can also be used for sewage, but only temporary measures, and the life expectancy, the effect can not be guaranteed.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range