Product Description:

Quick Details


Place of Origin:

Henan China (Mainland)

Brand Name:

KAIQI

Model Number:

Low,medium,high voltage

Insulation Material:

PVC, XLPE, PE

Type:

Low and Medium Voltage

Application:

Overhead, Construction, Underground, Industrial, Power Station,Industry, Commercial

Conductor Material:

Aluminium or Copper

Jacket:

PVC, XLPE, PE

conductor:

aluminium or copper

Voltage:

low & medium

Quality:

First Class

Color ID:

Red, Gree,Brown,Blue,Black

Technical Performance:

IEC, BS, VDE, ASTM, IS

Shield/Screen:

Copper Tape, Copper Wire

Armour:

Steel Tape/ Steel Wire/ Aluminium Wire/ Aluminium Tape

insulation/sheath:

PE, XLPE, PVC

core:

single or multi-cores





LV&MV, Al/Cu Conductor, Insulation/Sheath PVC/PE/XLPE, Shield CTS/, Armour SWA/DSTA/ATA, Power/ABC/ACSR/Control/Overhead cable

 

Power cable

 

1. Material: Cooper, Aluminum

 

2. Rated voltage: low and medium voltage 

 

3. Wire identification: Red, yellow, blue, white, black

 

4. No. Of cores : Single core cable: from 1.5 mm2  to 800 mm2; Multi-core cable: from 1.5 mm2 to 400 mm2

 

5. Standard:   Low voltage: IEC60502-1 Medium voltage :IEC60502-2 or other requirement.

 

6. Insulation: PVC, XLPE, PE

 

7. Sheath:PVC, PE, XLPE 

 

8. Armor:   Galvanized steel wires armouror Galvanized steel tape armour Aluminium Tape Armour/ Aluminium Wire Armour.

 

9. Application: Suitable for indoor, channel, conduit,underground,vertical well etc.

 

10. Nominal cross section area: from 1.5 mm2 to 800 mm2.


Aerial Bundle Cable Service Drop

 

 1. 3x35+54.6+16  3x50+54.6+16  3x70+54.6+16 3x95+70+16  3x120+70+16 3x150+70+16 mm2

 

 2.2x16mm2 2x25mm2 2x35mm2 2x50mm2 4x16mm2 4x25mm2 4x35mm2

 

3. Standard: ASTM ANSI, ICEA S-76-474, NFC 33-209 or other request.

Overhead electrical stranded cable (Bare Conductor)

 

1.Material: 1) Aluminum stranded wire and aluminum alloy stranded wire 2) Overhead stranded galvanized steel wire 3) Aluminum clad steel

 

2. Type: AAC, AAAC, ACSR, ACAR.

 

3. Standard:  AAC: GB/T 1179-2008 IEC 61089 ASTM B232 BS 215 part1, DIN 48201-5 or other requirement.

 

AAAC:GB/T 1179-2008,  IEC 61089, ASTM B 399   BS3242, DIN 48201-6 or other request.

 

ACSR : GB/T 1179-2008,  IEC 61089,  DIN48204,  ASTM B232,  BS215 PART 2or other request.

 

  

4.Application: These cables most widely used aerial line in aerial electric transmission lines and main product to form a power grid.

Aerial Insulated Cable

 

1. Material: Aluminium, copper

2. Type: LJ, LGJ, LGJF, JL, JLHA, JL/G, JLHA/G, JL/LHA, JL/LB, JLHA/LB, JG, JLB.

3. Rated Voltage: 0./1 kV, 10kV, 35kV. 

4. No. of cores: 1, 2, 3, 4, 3+k(A), 3+k(B). 

5. Standard:   GB/T12527  GB/T14049 or other.

 

6. Insulation: PVC, PE, xlpe

 

7. Sheath:PVC, PE, XLPE

 

8. Application: applying in cable fixed aerial laying or used as wire leading into user's premises.

 

9. Nominal cross section area: from 10 mm2 to 710mm2.

Control Cable

 

1.Material: Cooper 

 

2.Rated voltage: 300/500V, 450/750V, 0.6/1 kV. 

 

3.No. Of cores :  2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, 61

 

4.Standard:   GB/T9330, IEC or customers' requirement.

 

5.Insulation: PVC, XLPE, PE 

 

6.Sheath:PVC, PE, XLPE

 

7.Armor: Steel wire, Steel tape

 

8.Application: Suitable for chambers, tunnels and ducts, light-current control system and heavy-current magnetic interference region etc.

 

9.Nominal cross section area: 0.5~10mm²

PVC Insulated Electric Wires & Cables

 

1.Material: Annealed copper wires, bunched(class 5); Solid copper wire(class

 

2.Rated voltage: 300/500v and 450/750v    

 

3.Wire identification: Red, yellow, blue, white, black

 

4.No. Of cores : single core, 2 cores,3 cores,4 cores, 5 cores

 

5.Standard: IEC 60227 or according to customers' requirement.

 

6.Insulation / Sheath : PVC   

 

7.Application: Fixed wiring, house wire, building etc.

 

8.Nominal cross section area: from 0.25 to 240.






Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Emergency cable T-box and cable distribution box of the information?
Cable distribution box according to its electrical composition is divided into two categories: one is not any switch equipment, the box only the cable end of the processing and connection of the attachment, the structure is relatively simple, smaller, more functional , Can be called ordinary distribution box; the other is not only the general distribution of the box annex, but also contains one or more switchgear, its structure is more complex, larger, more connected devices, manufacturing technology Large, high cost, can be called advanced distribution box
Q:How to effectively reduce the cost of car wiring harness?
5mm, that is 100: 76 followed by the proportion of push The height of the isosceles triangle at the time of the bend of the 200 high bridge is also suitable for the adjustment of the 90 ° bend; the use of the tool is cut off and the bending of the bridge is 90 ° Bridge elbow As for the length of the bridge to limit the restructuring of the elbow, as long as the use of junior high school learned by the simple mathematical knowledge of the calculation, any length distance can be controlled The use of mathematical methods simple calculation, a variety of angles, the length of the elbow can be made zuo
Q:What is the use of wire and cable per square meter of residential building?
Generally wear SC65 tube. If the distance is too long, elbow and more, then the choice will be larger.
Q:1.2 meters below the road can use pvc tube wear armor cable?
MR is a metal bridge laying, the bridge width of 200 high 100
Q:Power cable ZRYJV-4x70 + 1x35 What does it mean?
2 cable in a variety of environments in the laying of the layout, spacing should meet the design requirements
Q:Whether the interior decoration is the first brush latex paint or the first installation of the wire (the line, with the trunking)?
100-200 door is to call the wiring module, testing and convenient. The The Switch on the use of national prestige WS824 figures. The
Q:Computer host configuration of about 1,000 yuan (preferably 1000 below) - probably as follows;
Cable trench as a power construction project should be cable trench construction construction design, cable trench construction program, according to the previous design requirements and programs in order to develop cable trench construction quality acceptance procedures
Q:1omoons / days sensitive quad-core network set-top boxes can be used on old-fashioned televisions.
Pipe protection cable to wear metal hose, metal hose and galvanized pipe to use metal lock connection, the connection can not pull the light pull on the line. If there is no metal hose or no metal lock, in the pipe when the pipe toward the cable to the appropriate bending, preferably in the mouth of the cushion cable skin, and then use the electrical adhesive tape sticky, sticky. After the nozzle cut with a polisher smooth grinding, the provincial scratch cable.
Q:What is the role of patch panels generally, why should the switch connected?
Customers want what you should have, others do not you should have. Shop to people-oriented.
Q:Can 110kv and 10kv cables co-share with trenches? What is the relevant specification?
According to Article 22.7.1 of the Electrical Design Code for Civil Buildings JGJ16-. the transmission lines and the electronic information system transmission lines shall be laid separately and shall be shielded when they are close to the laying of them in parallel by the construction conditions. High-voltage cable under normal circumstances is not allowed and weak cable with the ditch laying. If the relevant control cable does need to be with the high-voltage cable ditch, should be laid on both sides of the laying and keep the distance, but also pay attention to control cable shielding measures.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range