AC Solar Water Pumps for Irrigation Purpose

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
3000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.  Description of solar pumps. 

CNBM Solar Water Pump is the pumping facility driven by solar energy, which consists of a solar pumping inverter and a pump. Solar water pumps kit is called  solar pumping system combining with solar arrays designed according to different head and daily water flow for application. System is widely utilized for agriculture irrigation,desert control,pasture animal husbandry,city landscaping,daily water supply, etc.

 

In recent years, with the development of photovoltaic products from city application to huge demands of agriculture,pasture,desert areas, CNBM Solar Pond Pump has become the leading products combining photovoltaic industry with traditional industry such as agriculture water conservancy,desert control,daily water supply,city landscaping, etc.


CNBM Solar Pump driven by infinite solar energy, works from sunrise, and stops at sunset, need no connection to grid power nor diesel oil and battery. System can irrigate directly or store water instead of electricity in a reservoir. Solartech Solar fountain Pumps works with sprinkling irrigation, drip irrigation and infiltrating irrigation facilities, can be more efficient for water saving and dramatically lower the cost of using fossil energy.

 

2. Technical Function

1>  High efficient DC brushless motor requires less solar array. Rich social benefits.

2>  Optional centrifugal pump for big flow and helical rotor pump for high lift.

3>  High efficient semiconductor device used in main circuit. High reliability. Up to 98% conversion efficiency  of controller.

4>  Independent intellectual property of dynamic VI maximum power point tracking (MPPT) algorithm. Fast  response  and good stability. 99% MPPT efficiency.

5>  Full automatic operation. Complete protection functions. Integrated with water level monitor to prevent

  overflow and dry running.

6>  Full aluminum alloy case. IP52 protection grade. Ambient temperature: -20~+60.

Product Specifications


3. Specification details. 

1> Flow: 0.4m³/h~22m³/h

2> Head: 10m~210m

3> Power: 0.1~3Kw

 

4. FAQ

1> May we ask if the bare pump or the whole pump system would be all right for you to arrange the delivery?

     The bare pump and the who systems would be all acceptable at your side. A controller will be equipped with the pump freely. Regarding the whole system, we can also make the best solar panels configuration according to your requirements. 

2> Does your controller have the MPPT Function?

     Yes, our controller have. This would be not a problem. 

3> Can your pump work automatically?

     Yes, it would be the basic advantage of solar water pumps. 


AC Solar Water Pumps for Irrigation Purpose



AC Solar Water Pumps for Irrigation Purpose




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What should I pay attention to when buying a pump?
Two, the first choice of large and medium-sized professional manufacturers, and through the quality identification of relevant departments, the market credibility of the better models, but also to the professional quality inspection institutions consultation.Three, check the motor grounding device for electric pump, water pump and motor axis, the motor should be in a proper position is provided with a grounding screw, and the grounding screw are arranged near the ground; grounding device of small submersible pump should be reliable and grounding wire, grounding wire cables should have the obvious grounding mark the flag should be in use; the motor is not easy to be worn during the period. This is one of the important safety indexes of electric pumps.
Q:What does the impeller on the centrifugal pump mean by the first cutting?
There are 2 situations, first, for example, a XXXX-160 type pump head 32, flow 100, motor 15kW, according to the model we need to cut a become head 28, flow rate of 88, this time, in addition to cutting the impeller, the pump or the original pump motor, became 11kW this is, re designed a new model, namely XXXX-160A, but most structural components did not change. In the same way, we want to design a XXXX-160B that makes the head 24 and the flow rate 80, then we just need to cut the impeller again and match the smaller (7.5kW) motor (the motor bracket needs to be redesigned). In general, multiple cutting impellers are designed to expand and enrich the model. Second, the actual use, if you think the flow head is too large, but also can be cut to make it smaller to adapt to practical applications. But the 2 and 3 cuts you ask are the first.
Q:What are the causes of pump shock?
6., water pump relatively serious cavitation, improve the water level of the water tank, reduce water output7., impeller and motor rotor imbalance, overhaul8. pump shaft bending or abrasion overhaul
Q:Is the diaphragm pump and the drain pump one?
First of all, there's something wrong with your concept.Diaphragm pump is in accordance with the way the pump classification, drain pump is in accordance with the use of pumps classification.
Q:How many kinds of pumps are available and the operating principles of various pumps?
There are many kinds. See what divides.According to the working principle can be divided into: the power type pump, also called pump or impeller vane pump, depending on the dynamic effect of the rotation of the impeller on the liquid, the continuous energy transfer to the liquid, the liquid kinetic energy (mainly) and the pressure will increase, then converting kinetic energy into pressure energy through the discharge chamber, and can be divided into centrifugal pump, axial flow pump, partial flow pump and vortex pump etc..
Q:What is double hydraulic pump?
Two hydraulic pumps installed on one shaft can be connected to increase output flow, and can also be connected to increase output pressure. See how the demand is. The system can change the mode of application at any time.
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
Submersible pump even if it really leakage, it will not cause the fish electric shock. The so-called leakage is the submersible pump wire or shell broken, live parts and water contact, the most extreme test is a fire line directly into the fish tank
Q:What is the difference between an air pump and a water pump?
Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.
Q:How many square cables does the submersible pump for 7.5KW need?
7.5KW's submersible pump requires 2.5 square aluminum cables.Calculate the current value of submersible pump first:
Q:What are the differences between the sewage pump and the clean water pump?
2. in order to prevent the wound, water pump impeller design is more simple but not ring pump, equipped with tips, cloth and other debris can be crushed after the pump, and the impeller water pump is relatively complex, but the efficiency will be significantly higher than the former.Why can't the sewage water pump and impeller: because features of key design, resulting in water pump for sewage situation is likely to occur, blocking, winding, wear and corrosion occurs, resulting in damage to pump or scrapped, so water pump can not be used for sewage.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range