• AC Pump System System 1
AC Pump System

AC Pump System

Ref Price:
get latest price
Loading Port:
Shekou
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
300000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Products

Solartech China Solar Water Pump is the pumping facility driven by solar energy, which consists of a solar pumping inverter and a pump. Solar water pumps kit is called  solar pumping system combining with solar arrays designed according to different head and daily water flow for application. System is widely utilized for agriculture irrigation,desert control,pasture animal husbandry,city landscaping,daily water supply, etc.


In recent years, with the development of photovoltaic products from city application to huge demands of agriculture,pasture,desert areas, Solartech Solar Pond Pump has become the leading products combining photovoltaic industry with traditional industry such as agriculture water conservancy,desert control,daily water supply,city landscaping, etc.


Solartech Solar Pump driven by infinite solar energy, works from sunrise, and stops at sunset, need no connection to grid power nor diesel oil and battery. System can irrigate directly or store water instead of electricity in a reservoir. Solartech Solar fountain Pumps works with sprinkling irrigation, drip irrigation and infiltrating irrigation facilities, can be more efficient for water saving and dramatically lower the cost of using fossil energy.

Technical Features

Solar Water Pump is a pumping device powered by solar energy, consists of a solar pumping inverter and a deeo well pump, mainly used for agriculture irrigation, desert control, pasture animal husbandry, city waterscape, seawater desalination, living water supply and so on.

Use solar energy, need no connection to grid.         Automatically operation, maintenance free.
Easy to install and move, high universality.              Clean and green, high economic benefits.

Solartech solar pump kit also named solar water pumps, solar pond pump, solar borehole pump, solar funtain pumps, solar powered water pump, solar irrigation pump, solar deep well pump, and solar submersible pump.

Product Specifications

Model

Pump Spec.

Adapting Water Head

Daily Water Supply

Outlet internal Dia.

Adapting well Dia.

Recommended Open Circuit Voltage

Recommended MPP Voltage

SPA4370010

3PH 220V 50Hz

47-32m

1-10 m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4370020

3PH 220V 50Hz

29-20m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4550010

3PH 220V 50Hz

70-48m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4550020

3PH 220V 50Hz

40-28m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4550040

3PH 220V 50Hz

23-15m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA4750010

3PH 220V 50Hz

81-56m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4750020

3PH 220V 50Hz

60-41m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA4750040

3PH 220V 50Hz

29-19m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA4750060

3PH 220V 50Hz

15-8m

40-60m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA4750100

3PH 220V 50Hz

7-6m

60-100m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K1010

3PH 220V 50Hz

93-63m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K1020

3PH 220V 50Hz

79-54m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K1040

3PH 220V 50Hz

43-27m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA41K1060

3PH 220V 50Hz

23-12m

40-60m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K1100

3PH 220V 50Hz

12-8m

60-100m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K5010

3PH 220V 50Hz

128-87m

1-10m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K5020

3PH 220V 50Hz

99-68m

10-20m3

30mm

1"1/4

100 mm

350-450VDC

280-350VDC

SPA41K5040

3PH 220V 50Hz

51-33m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA41K5041

3PH 220V 50Hz

60-39m

20-40m3

40mm

1"1/2

100 mm

350-450VDC

280-350VDC

SPA41K5060

3PH 220V 50Hz

29-15m

40-60m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K5130

3PH 220V 50Hz

10-7m

100-130m3

50mm

2"

100 mm

350-450VDC

280-350VDC

SPA41K5100

3PH 220V 50Hz

20-12m

60-100m3

65mm

2"1/2

150 mm

350-450VDC

280-350VDC

SPA42K2010

3PH 380V 50Hz

163-111m

1-10m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA42K2020

3PH 380V 50Hz

145-90m

10-20m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA42K2040

3PH 380V 50Hz

79-51m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA42K2060

3PH 380V 50Hz

50-27m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA42K2130

3PH 380V 50Hz

17-12m

100-130m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA42K2100

3PH 380V 50Hz

30-18m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA43K0020

3PH 380V 50Hz

187-114m

10-20m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA43K0040

3PH 380V 50Hz

105-65m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA43K0060

3PH 380V 50Hz

67-37m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA43K0061

3PH 380V 50Hz

79-43m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA63K0100

3PH 380V 50Hz

40-24m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA63K0130

3PH 380V 50Hz

23-16m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA63K0250

3PH 380V 50Hz

18-9m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA44K0020

3PH 380V 50Hz

225-149m

10-20m3

30mm

1"1/4

100 mm

625-750VDC

500-600VDC

SPA44K0040

3PH 380V 50Hz

145-89m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA44K0060

3PH 380V 50Hz

94-55m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA44K0100

3PH 380V 50Hz

50-32m

60-100m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA64K0100

3PH 380V 50Hz

56-36m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA64K0130

3PH 380V 50Hz

30-22m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA64K0131

3PH 380V 50Hz

37-27m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA64K0250

3PH 380V 50Hz

26-13m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB64K0500

3PH 380V 51Hz

17-6m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA45K5040

3PH 380V 50Hz

172-111m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA45K5060

3PH 380V 50Hz

113-62m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA45K5100

3PH 380V 50Hz

67-44m

60-100m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA65K5100

3PH 380V 50Hz

75-48m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA65K5130

3PH 380V 50Hz

53-39m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA65K5250

3PH 380V 50Hz

35-21m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB65K5500

3PH 380V 50Hz

25-10m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA47K5040

3PH 380V 50Hz

237-147m

20-40m3

40mm

1"1/2

100 mm

625-750VDC

500-600VDC

SPA47K5060

3PH 380V 50Hz

137-75m

40-60m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA47K5100

3PH 380V 50Hz

87-57m

60-100m3

50mm

2"

100 mm

625-750VDC

500-600VDC

SPA67K5100

3PH 380V 50Hz

114-67m

60-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA67K5130

3PH 380V 50Hz

67-50m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA67K5250

3PH 380V 50Hz

44-25m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA67K5251

3PH 380V 50Hz

52-30 m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB67K5500

3PH 380V 50Hz

33-15m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA69K2100

3PH 380V 50Hz

140-85m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA69K2103

3PH 380V 50Hz

83-60m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA69K2250

3PH 380V 50Hz

62-40m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB69K2500

3PH 380V 50Hz

42-20m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA611K100

3PH 380V 50Hz

159-97m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA611K130

3PH 380V 50Hz

105-77m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA611K250

3PH 380V 50Hz

72-46m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB611K500

3PH 380V 50Hz

50-23m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA613K100

3PH 380V 50Hz

189-115m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA613K130

3PH 380V 50Hz

120-88m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA613K250

3PH 380V 50Hz

81-52m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB613K500

3PH 380V 50Hz

59-27m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA615K100

3PH 380V 50Hz

208-127m

40-100m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA615K130

3PH 380V 50Hz

135-99m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA615K250

3PH 380V 50Hz

88-58m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB615K500

3PH 380V 50Hz

67-31m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPA618K130

3PH 380V 50Hz

143-109m

100-130m3

65mm

2"1/2

150 mm

625-750VDC

500-600VDC

SPA618K250

3PH 380V 50Hz

101-63m

130-250m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPB618K500

3PH 380V 50Hz

83-39m

150-500m3

76mm

3"

150 mm

625-750VDC

500-600VDC

SPC822K270

3PH 380V 50Hz

86-70m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC822K330

3PH 380V 50Hz

70-55m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC822K420

3PH 380V 50Hz

55-48m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC822K540

3PH 380V 50Hz

48-36m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC822K700

3PH 380V 50Hz

36-25m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC826K270

3PH 380V 50Hz

105-85m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC826K330

3PH 380V 50Hz

85-65m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC826K420

3PH 380V 50Hz

65-55m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC826K700

3PH 380V 50Hz

44-30m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC830K270

3PH 380V 50Hz

125-105m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC830K330

3PH 380V 50Hz

105-85m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC830K420

3PH 380V 50Hz

85-70m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC830K540

3PH 380V 50Hz

70-52m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC830K700

3PH 380V 50Hz

52-35m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC837K270

3PH 380V 50Hz

150-125m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC837K330

3PH 380V 50Hz

125-100m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC837K420

3PH 380V 50Hz

100-80m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC837K540

3PH 380V 50Hz

80-60m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC837K700

3PH 380V 50Hz

60-40m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC845K270

3PH 380V 50Hz

180-145m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC845K330

3PH 380V 50Hz

145-120m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC845K420

3PH 380V 50Hz

120-98m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC845K540

3PH 380V 50Hz

98-72m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC845K700

3PH 380V 50Hz

72-50m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC855K270

3PH 380V 50Hz

200-170m

210-270m³

65mm

2.5"

250-300mm

625-750VDC

500-600VDC

SPC855K330

3PH 380V 50Hz

170-155m

270-330m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC855K420

3PH 380V 50Hz

155-125m

330-420m³

76mm

3"

250-300mm

625-750VDC

500-600VDC

SPC855K540

3PH 380V 50Hz

125-95m

420-540m³

100mm

4"

250-300mm

625-750VDC

500-600VDC

SPC855K700

3PH 380V 50Hz

95-65m

540-700m³

100mm

4"

250-300mm

625-750VDC

500-600VDC


Q:I just had my water pump replaced and a coolant flush. 35 miles later, my MAL light came on and my mechanic said my thermostat needs replacement. Should this have been done with the water pump work, or could the work have caused the thermostat problem?
Anytime I replace a water pump, intake gasket, or anything else where the coolant needs removal, I always suggest to my customers that we change the thermostat as well. Many times I just change it anyway. I tell the customers, but really don't offer an option! (of course if they say don't I will honor that, but no one has ever said that!) It is possible that during a flush some trash/scale got into the thermostat causing improper operation. With the thermostat removed, there is no restriction in the cooling system making flushing easier and more thorough. Now to answer your question, It is my opinion he SHOULD HAVE. That is not only an up-sell (even though I hate creating extra work) it is just an added value to the customer. He should also check belts and hoses, changing them (via customer approval) if needed. As a mechanic, the last thing I want is a comeback such as yours was because I at the very least didn't suggest a proper service!
Q:It is a 110 shallow well pump for my water source to the house.
The pump will turn on when it detects a loss of prepressuren the system or if there is a bad foot valve in the well. A bad foot valve lets water back into the well thus lowering the pressure in the system. An overlooked problem may be found in the toilets and is sometimes undetectable unless you take the tank top off, flush the toilet and wait for it to fill and listen for any hissing noises coming from the fill valve or if the water level in the tank is too high which will allow water to go down the over flow tube after the tank is full and will kick the pump back on after a while. Check for drippy faucets including your outside hose bibs. I deal with this on a regular basis and it is a simple fix more times than not. Good Luck!
Q:honda acord water pump 1988
hello Purchase a how to book, because part of the water pump sits behind the timing belt cover.Hope this was some help.
Q:I have a deep tropical fish tank, my three in one pump is 15 watts, if I put it in the middle of the active oxygen bubbling tank can function, everything is normal, but not very good filtering, can not clean up the garbage at the bottom of the tank. So they put the pump a little deeper, but at this time the pump does not bubble, the oxygen supply in the pipe there is water, atmospheric pressure can not enter, but still can pump water filter, so that the pump itself harmful? Will the pump burn out? This question is very important to me. Please help my brothers and sisters downstairs. I will thank you for my dear tropical fish
First tell you the pump not bad, just can't carry oxygen rinse, now he is equivalent to a 2 in a filter of the submersible pump, without any damage to the pump itself, three in one pump is actually in the 2 water outlet and air pipe, pressure by fluid flow is the principle of position the smaller the air drag, now a large pressure, oxygen loss of function, but the pump itself, his work without any change, so do not burn, rest assured it
Q:The water pump gasket in my '98 Forester (130k) recently began to leak, and I will be replacing it in the next couple days. I noticed a stream of bubbles in my overflow container, though, and am wondering if it might be bad head gaskets making the air bubbles. The bubbles only appear after the engine is warmed up, like after a drive around town - there aren't any bubbles when the engine is cold.Is it possible that these air bubbles are coming from the leaking water pump? I hope so, because I'd much rather replace the pump than the head gaskets!
I have yet to witness a leaky water pump suck air into the cooling system . If you are seeing bubbles in your radiator after the vehicle heats up see if the temperature is also higher [the hot gasses will heat up your coolant and eventually can push your antifreeze to the reservoir tank ] it can result in boil over.I strongly believe you have a bad head gasket that has not entirely blown yet Have the compression checked per cylinder,and for water getting into your oil (it would become a milky brown and become frothy a little bit) if that is all ok, then maybe just maybe a pump sucking air is occurring, though I have never seen it or herd of it before in my entire life.
Q:Our watrer pump on our well will constantly prime itself when we use the water in our house.As you are running the tap the water will gain pressure on and off like someone is using another tap in the house. Any suggestions?THanks in advacne
How old is the Pump ? Could the Impeller be worn out ? Is there a replaceable filter ? Could it possibly be stopped up ? Are there any leaks in the pipe leading from the well ? Is there a way that you could measure the current being drawn by the pump, with an Amp Meter, to determine if it's pulling more Current than it should be ? Until these questions are answered, it's probably just going to be a guessing game.
Q:can't get the pulleys to line up I know I have a mid 70's 400 and the water pump is later than 1969 but I can't find a pulley that works every one is about a half inch off I bought a aftermarket set of underdrive pulley's from march performance and still the same problem the water pump is a half inch off there was no long or short water pump right they are all the same lenght right??? The only difference I know of is that pre 1968 the pumps have a 8 bolt design and after they have a 11 bolt design is that right???
Actually there was two main pumps for the older ones,, one was called a short shaft,,and one was called a long shaft,,the long shaft was the most popular,and it all depends on whether your car had power steering,,and air conditioning on it,,all the ones that used the long shaft usually had air,,and power steering on them also,,also some of them had a smog pump on them,,this was the main reason they used the long shaft,,most of the smog pumps got taken off and discarded down through the years,,but you still had to use the pump that had the long shaft,,this is the problem your having,,i own a repair shop in Tennessee,,and have been redoing some old cars in the past few years i to have run across the same problem you are having,,you can have a long shaft ordered for you ,,and it will work fine,,i had to use the long shaft on the one i was redoing hope this helps some.
Q:How do you check water pump on 98 deville haveing overhea?
You can't really check the water pump except that with the belt off, you wiggle it to look for play in the bearing. When the bearing gets loose, it causes seal failure and massive coolant loss. But after 100k miles it is time to do the pump anyway. Not that hard or expensive. Do the thermostat as well, just in case. But if no coolant loss, then overheating is probably from something else, like bad plug wire, intake manifold leak, plugged catalytic converter, retarded ignition, head gasket, etc. If the radiator was not clear, then the electric fan would go on often. Not likely radiator. Depends also on when heats up. If city driving, then likely to be fan or switch. If highway driving, then plugged convertor more likely. Put cooling system pressure tester on radiator cap. Check for leaks under higher than normal pressure. See if holds pressure. Then start engine and see if cylinder leak causes oscillation.
Q:How does a pump get water from a low low elevation to a higher elevation.
To understand the working of a hand pump, you have to understand the working of a basic pump. Pumps work by creating a difference in pressure ( in this case of water). A sort of vacuum is created at the top of the pipe while water is present at the lower end. There is a difference in pressure hence water rushes to the top-end of the pump from where we get water. This vacuum is created by the mechanics in the electrical pump. Regards -M.S P.S : Please select as 'best answer' if you like my answer...
Q:I must change the timing belt of my car. I have been told that the water pump must be done too since it is right there. Due to the high price I want to postpone/skip the water pump until the next tune up. What happens if the water pump fails down the road? How long does a water pump last? 120K? My car has 60,000 miles on it. Thank you.
You don't have to renew the water pump. They mention it because it becomes easily accessible during the timing belt replacement. The extra cost should only be the cost of the water pump. So it's often sensible to include the water pump at the same time. If you do it at the next service it will cost you at least the same as you are paying now for the belt job.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords