ABC ( Aerial Bundled Cable , Service Drop )

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

ABC,Aerial Bundled Cables,Service Drop

  •  Duplex Service Drop  ABC Cable used for overhead service applications such as street lighting,temporary service ,and so on

  •  

    Primarily used for overhead service applications such as street lighting,outdoor lighting,and temporary service for constrction.To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crossliked polyethylene(XLPE) insulated conductors.

    It meets or exceeds the following specifications:

      1.Aluminum Wire,1350-H19 for Electrical Purposes.

      2.Aluminum Conductors,Concentric-Lay-Stranded.

      3.Aluminum Conductor,Concentric-Lay-Stranded,Coated Steel Reinforced(ACSR)

      4.Concentric-Lay-Stranded 6201-T81 Conductors

      5.Compressed Round Stranded Aluminum Conductors Using Single Input Wire.

    It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

Cable
 Size 
Conductor 
Diameter 
Insulation 
Diameter 
Support 
Core Size 
Overall 
Diameter 
Cable 
mass 
Res. DC
 @ 20~C 
Res. AC 
@ 90~C 
Impedance Symmetrical 
Current 
Current 
Rating in Air 
mm2 mm mm mm2 mm kg/km ./km ./km ./km kA Amps 
256.59.554.622.94201.21.541.5412.3105
357.310.554.625.35550.8681.111.1173.3130
508.311.754.628.17520.6410.820.8264.7165
7010.213.654.632.810120.4430.570.5746.6205
9512.315.954.638.213480.320.410.4199250
12013.517.17041.216510.2530.330.33411.3290
15015.319.39546.520650.2060.270.27614.2

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Where's my power adapter cable for my hard drive?
Hard disks typically use the 4-pin molex connectors. I can see at least two free in your picture. Basically just use the one that fits, there should only be one that fits anyway.
Q:power cable for internal dvd player?
You need a molex cable. Here is a page you can check out to get some 1 to 2 adapters for molex cables. I have ordered things from them before and was very pleased:
Q:Car amplifier power cable?
Try a new power cable, if i were u, I WOULD def. go with 0 guage Memphis wire, which is 95% pure copper. Its very good wire, top quality. Your old wire just burned out cuz it was probably around 10% copper.
Q:Hard drive choices/power cables? Help?
Fantasy power outlets don't sound standard. SATA is consistent on both PCs and Macintosh computers.
Q:Lawn mower power cable cut - mowing?
so replace the power line.
Q:What is a AC POWER CORD CABLE EXTENSION CORD used for? 10 points?
It is used to either extend a power inlet cable (usually an IEC type), or connect the power outlet on a device to the power inlet on a device, where they use IEC connectors.
Q:what are the power cables on the back of a dell monitor called?
One is the power supply cable (Black one) and since its blue the second one would be a VGA cable. Hope this helps.
Q:why I only get 10MB in cat5 cabling?
Power cables cause interference as well as distance and twists in the wire. I assume you have a cable that you made. Did you try a pre-made cable at a shorter distance to see if the ethernet card will do 100mb at all? If it works with the premade, you might have not wired the 80' cable correctly. Make sure you have the pairs crimped correctly in the connector. Pins 1 and 2 are a pair. Pins 3 and 6 are a pair. Pins 4 and 5 and 7 and 8 are paired as well. Example: Orange/white = pin 1 Orange=pin 2 Green/white=pin 3 Green = pin 6 Blue = pin 4 Blue/White = pin 5 Brown/white = pin 7 Brown = pin 8 I hope this helps.
Q:Can we wire coxial cable beside power cable?
Check with city laws vary but no they don't want coax in the conduit with power wires
Q:use 12.5vdc adapter in +12vdc cable modem? i lost the power cord and hope to use a sub but voltage is differnt?
You need the correct voltage and the correct current (amps) from your adapter. Look at the old adapter - it will say what the current output is (e.g., 2 AMPS).

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range