ABC Aerial Bundled Cable,Service Drop

Ref Price:
Loading Port:
China main port
Payment Terms:
TT or LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

ABC Aerial Bundled Cable,Service Drop

Main Structure

1.ABC cable
2.Iso -9001 quality guarantee
3.Manufacture direct sales,competitive price
4.Small quantity accepted

ABC,Aerial Bundled Cables,Service Drop

  •  Duplex Service Drop  ABC Cable used for overhead service applications such as street lighting,temporary service ,and so on

     

Application:

  • Primarily used for overhead service applications such as street lighting,outdoor lighting,and temporary service for constrction.To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crossliked polyethylene(XLPE) insulated conductors.

It meets or exceeds the following specifications:

 

  •   1.Aluminum Wire,1350-H19 for Electrical Purposes.

      2.Aluminum Conductors,Concentric-Lay-Stranded.

      3.Aluminum Conductor,Concentric-Lay-Stranded,Coated Steel Reinforced(ACSR)

      4.Concentric-Lay-Stranded 6201-T81 Conductors

      5.Compressed Round Stranded Aluminum Conductors Using Single Input Wire.

    It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

     

 Datas and Information

Cable
 Size 
Conductor 
Diameter 
Insulation 
Diameter 
Support 
Core Size 
Overall 
Diameter 
Cable 
mass 
Res. DC
 @ 20~C 
Res. AC 
@ 90~C 
Impedance Symmetrical 
Current 
Current 
Rating in Air 
mm2 mm mm mm2 mm kg/km ./km ./km ./km kA Amps 
256.59.554.622.94201.21.541.5412.3105
357.310.554.625.35550.8681.111.1173.3130
508.311.754.628.17520.6410.820.8264.7165
7010.213.654.632.810120.4430.570.5746.6205
9512.315.954.638.213480.320.410.4199250
12013.517.17041.216510.2530.330.33411.3290
15015.319.39546.520650.2060.270.27614.2

 

Picture

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Computer host configuration of about 1,000 yuan (preferably 1000 below) - probably as follows;
"Electrical design of civil buildings," 8.10.13; steel cable bridge straight section length of more than 30m, aluminum or glass fiber reinforced plastic cable bridge length of more than 15m, should be set up expansion joints. Cable bridge across the building deformation joints, should be set compensation device. The telescopic section is set for temperature change; the compensating device is to prevent settlement at the deformation.
Q:What is the difference between data cables and power cables?
What do you think? Data cables are used to power up the device, and the power cable is used to transfer data.
Q:sony bravia damaged ac power cable?
Change the cable and give the hamster away.
Q:Acoustic Audio 10 inch home theatre powered subwoofer use speaker wire or subwoofer cable?
Use a long RCA cable. If you use speaker wire - you have to run wires from the left/right outputs to the sub, then more wire from the sub to the left/right speakers. Then you have to tell your receiver your left/right speakers are LARGE and you do not have a sub to get things to work. A single long RCA cable is simpler. You can even make your own with pre-terminated CATV coax and some F-to-RCA-Male adapters from Radio Shack. Subwoofer signals work fine and do not need any kind of higher end RCA cable.
Q:Question about threading a coaxial cable through brick?
A drill with a concrete bit (large enough to pass the wire, but smaller than the grout line(( cement between the bricks)). Try to determin where the studs in the wall are from the inside of the room and transfer to the outside. Drill a hole in the grout, then change the concrete bit for a long wood spade bit of the same size and drill a hole straight threw the wall. Leave the drill bit in the wall and attatch a small wire to the bit point with tape and pull back to the outside. Then put the cable onto the wire with tape as befor and pull threw the wall. Install a remodlers electric box and cover plate. Hope this helps Mike
Q:What does the cable (YJV-5 * 6) mean?
ZR-flame retardant Y-polyethylene J-crosslinked V-PVC sheathed YJV is copper core, YJLV is expressed as aluminum core, where L is aluminum. 22 indicates the type of armor armor, and 32. So the full name is: flame retardant copper conductor cross-linked polyethylene insulated PVC sheathed power cable 4 * 16 that there are a total of four copper wire, which each cross-sectional area of 16 square millimeters
Q:Is it safe the touch a hooked up 4 gauge power cable when a car is running?
Anything below 30 amps DC will not hurt ya. However,.. you CAN get shocked by DC voltage. -its when you get up around 75 amps that will feel hot like a fire heated wire. At around 150 amps it still won't shock you like AC current but will make you pee on yourself.
Q:Will PS2 controllers and power cables work on a PS3?
Controllers, yes, you just need a special adapter. Power cable, absolutely not, since the PS3 Fat uses a 3-prong power cable like what computers use and the PS2 uses a completely different kind with only 2.
Q:I desperetly need your help PLEASE!!! My PS3 power cable got taken!?
Find the correct cable for your PS3 : shop.OKorder.co.uk/?_from=R40_trksi...
Q:Can I mix different power cables / transformers for different electronics? The plug does fit in.?
uk is now 230, the ecu voltage. (easily, capacity is transmitted under the Channel from France throughout the frenzy hour, that's a risk simply by fact the Continent is on needed ecu Time; no longer correct on your question yet exciting.) some electronics bought interior the USA of a are marked one hundred twenty˜240 and those could be utilized interior the united kingdom with basically a plug adapter. Hair dryers and another home equipment have outfitted in resister circuits and you will pass a swap from one hundred twenty to 230/240. or you elect a converter (no longer reported by way of many electricians different than as an emergency holiday expedient) or a transformer. you may desire to examine up the wattage or amperage or you will burn out the transformer. For digicam battery chargers etc, interior the no longer likely experience they are not twin voltage, you may positioned them interior the one hundred twenty v. socket of a batheroom shaver outlet (those have circuit breakers in them for a million amp or much less). I easily have not viewed any digicam chargers recently that are no longer twin voltage. yet confirm. you need to purchase adapters to extra healthful the unique British electric retailers in drug and equipment shops throughout Britain, and at airports.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range