A series of PVC insulated wire Information
Quick Information:This product is suitable for field lines, electrical instrumentation, telecommunications and broadcasting, electronic equipment and automation devices such as shielding lines
1 the product standard AVVR JB8734-1998 AVPV GB5023-1997
Specification: the use
Wire long-term allowable working temperature does not exceed +70 ℃
Laying temperature not lower than -15 ℃
Relative humidity: 98%

3the structure diagram

A Series of PVC Insulated Wire AVVR JB8734-1998
Characteristics:the main technical performance
1) Rated voltage (AC 50Hz)-380V-500V DC
2) Test voltage (AC 50Hz)-2000V
3) Insulation Resistance (20 ℃) is not less than 2MΩ.km
4) Wire and cable knit density is generally not less than 80%

5 delivery length
Cable delivery length of 150m or more, allowing more than 5m short section delivery, their number does not exceed 15% of total deliveries.
Executive standard: JB 8734-1998
AVVR

FAQ:

Installation laying temperature not lower than -15 ℃ 


allowed minimum bending radius: Interior of not less than five times the cable diameter

Outside of not less than 10 times the cable diameter

Products in accordance with the appropriate standards of production(GB/T1486-93;GB/T11138-97;JISAnd the U.S. military standard),Attenuation, interference is strong, structural asked Tung electrical performance is good, with good resistance to gas properties.


Picture:

A Series of PVC Insulated Wire AVVR JB8734-1998


A Series of PVC Insulated Wire AVVR JB8734-1998


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why is power connector longer than data cable connector on a sata hard drive?
The sata power connector provides 3.3, 5v and 12v as well as two ground connections (in between the 3.3 and 5 and 5 and 12) I believe. Anyway, for the power connectors, a single pin has a maximum rating of 1.5A or so, and so they provide three pins if a device needs needs more current.
Q:Will this power cable work for my 350 watt PSU?
yes it will work aslong as it fits
Q:Power cable YJV22-8.7 / 15kv-3 * 300 what meaning
Power cable YJV22-8.7 / 15kv-3 * 300 Meaning: refers to the copper core XLPE insulated double steel tape armored PVC sheathed power cable, cable rated working voltage 8.7 / 15KV, cable for the three-core, single Conductor cross-sectional area of 300mm2. YJ: cross-linked polyethylene insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated working voltage 8.7 / 15 kV 3 * 300 Specifications: YJV22-8.7 / 15kv-3 * : Three conductors, single cross section of 300 square feet.
Q:Why my home analog TV connected to the digital TV set-top box after the screen is black and white
Our teacher wants us to do the thermometer, but I do not know what to do. The What materials should I use? The Whether my straw is now pressed and deformed, and adjust the water level, so that the water level is slightly higher than the bottle, with oil pen in the straw
Q:how to put a switch into power cable for an amplifier in car ?
You can put a main power cut off to your amp. all you have to do is go to a truck stop and get a big power cut off switch and put it somewhere along the power cable. or you can just put a toogle o the blue wire.
Q:We say that the size of power cable is 4 core, 150 sq.mm. What would be the diameter of this cable ???
A 4core (electrical) cable of that strength is usually built up from quarter circle shaped sectional wires. (Think of a pizza cut into four even pieces.) So, calculate the outside diameter from this point and add 4 times the insulator thickness. Example: 400V 4core cable has very likely 1mm insulator thickness. 150mm² * 4 cores is 600mm² total. By A=PI*d'*d'/4, d' being the diameter without insulator, would be d'=2*sqrt(A/PI)=600mm²/3.1415...=2*sqrt(...‡ Now, as said above, add the 4 insulator layers, and then you would be at approx. 31.7mm outside diameter.
Q:I need to know if i can use 550 watt power cables from my old amp to power my new 700 watt amp?
yes you can those watts posted are peak power stats.. the rms wattage is less than half that so youll be fine
Q:PS3 Slim, hanging then yanking the power cable?
If pulling the power cord was the *only* way to turn it off, that's ok, you just don't want to do it frequently. As for the game itself, the only thing I can think of is to make sure other games work. If so, then something about the game itself is causing the fault, but not sure what. If anything, I would say contact Sony for assistance in that regard.
Q:imac G4 power cable Question?
It's an ordinary 3-pin PC power cable. Any desktop, screen or printer should use one. If you don't have one, you should be able to easily find one for £5.
Q:What is the power cable accessories used to do?
Do not know what you want to ask? What about your situation? Normal or pregnant? Normal this radiation does not affect what, if it is pregnant, this is far away from the best. Pregnancy is most needed to stay away from the microwave!

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range