86% Alumina 60 Mesh Calcined Bauxite with Low Price

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
25 m.t.
Supply Capability:
30000 m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

86% Alumina 60 Mesh Calcined Bauxite with Low Price

 

Specifications

1.    We directly supply calcined bauxite 

2.    Al2O3:70%/75%/80%/85%/86%/88%/90% 

3.    Size:0-1-3-5-8-10/200mesh/325mesh/400mesh/500mesh

 

Size:

Lumps /Grains:0-1mm,1-3mm,3-5mm,5-8mm /Powders:100mesh, 200mesh,325mesh

 

Product Description:

Bauxite, alumina or bauxite miner , main ingredients are aluminum oxide, hydrate alumina containing impurities,

is an earthy mineral.White or grey, brown yellow or light red by iron.From 4 to 3.9 g/cm3 density, hardness, 1 ~ 3, opaque, very brittle.

Very difficult to melt.Insoluble in water, soluble in sulfuric acid, sodium hydroxide solution.Mainly used for aluminium, refractory material.

 

Calcined Bauxite Grade:

Shaft Kiln Bauxite

Rotarty Kiln Bauxite

Round Kiln Bauxite

 

Packaging & Delivery

Packaging Details: In bulk or in 1-1.25mr bag

 

Product Pictures:


86% Alumina 60 Mesh Calcined Bauxite with Low Price

86% Alumina 60 Mesh Calcined Bauxite with Low Price

86% Alumina 60 Mesh Calcined Bauxite with Low Price

86% Alumina 60 Mesh Calcined Bauxite with Low Price


Our Service:

1. Your inquiry related to our products or prices will be replied in 24hours.

2. Manufacturer with large capacity, ensure the fast production cycle after confirmed the order.

3. Our professional technicians will answer your entire enquiry in patient.

4. To meet the refractory solutions, we can serve as your instructions.

5. Protection of sales area and private information for our entire customer.

 

If you’ve kind enquiries, please don’t hesitate to let us know. ^_^


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:what's the fireproof levels of fireproof and thermal inuslation matertial?
1, organic materials: B level material is flammable, B1 level material is flame retardant. 2, inorganic materials: Grade A flame-resistant materials are divided into three classes and two kinds of materials.
Q:Which schools are the best schools in the world for learning knowledge about refractories?
Wish it helps you out.
Q:Who knows about the B-level fireproof insulation materials?
Organics, extruded sheet, polyphenyl board and phenolic resin. The fireproof performance of sea capacity module (fireproof and thermal insulation material) is B1-level with the heat conductivity coefficient of only 0.028w / m · k. It is a good choice. A-level: Rock wool, glass wool, silicate, aluminum silicate, calcium silicate, phenolic aldehyde, and foam glass. B-level: Rubber and plastic, extrusion molding, polyphenyl, PEF.
Q:Why the refractories should be waterproof and wetproof
It is necessary to like magnesium carbon, waterproof and wetproof is more important. There is a variety of refractory materials, in general, basic is defective, and wherein the binder and additives water will lose their effect, the relationship is not very high aluminum large amount of water determines how much of the performance after the hydration will affect the strength and high temperature performance ;; hydration & quot, just need a little package like magnesium and calcium-based product itself readily react with water to calcium oxide, magnesium, chromium is not all the material goods have waterproof ordinary bulk materials need to add water before use
Q:What is the fireproofing requirements of external wall thermal insulation materials?
in the 2011 and 2012 revised version of "Fireproof  Specification of Building Design" in China, the external insulating layer of above 50 meters (approximately 16 layers) of the housing must use the level A material. The latest draft for approval is not so strict, above 100 meters (about 33 layers) only use level A material. The manuscript of "Building Regulations" is also regulated building's external wall thermal insulation materials in the crowded places should be level A. Except the residential buildings and the buildings in the crowded places, the height of other buildings is greater than 50 meters, combustion performance of insulation materials should be level A; the height buildings is greater than 24 meters but not more than 50 meters, combustion performance of insulation materials should not be lower than level B1. "Building Regulations" manuscript should relax the rules on the aspect of protective coating in level B1 and B2 insulation material. The outer of level B1 and B2 level insulation material must use incombustible material as protective coating, its thickness is changed from the original 10 cm to 5 cm. Given certain conditions, I feel you can use TDD exterior wall thermal insulation decoration integrated rock wool board for construction, which is level A fireproofing with a short construction period and good thermal insulation properties. I hope I can help you!
Q:Who can tell me what is neutral refractory?
Neutral refractories refer to the refractory materials which will not react greatly with both acidic and basic slag at high tempreratures. Such as carbon refractories and chromite refractories. The main components include carbon, silicon carbide, aluminum oxide, chromium oxide and other trivalent oxides, such as carbon refractories and chrome refractories, etc. Strictly speaking, neutral refractories refer only to the carbonaceous refractories, including carbon brick and graphite silicon carbide products, etc.
Q:Who can tell somthing about how to choose fire resistant rating of fire resistance rolling shutter doors?
There is no necessary connection between them. Different fire resistant ratings of bulidings require different fire endurance of different elemements of buildings. According to the fire endurance, fireproof doors can be divided into A-grade, B-grade and C-grade, whose fire endurance should not be less 1.2h, 0.9h and 0.6h respectively. A-grade fireproof doors can be even applied to the material whose fire resistant rating is at secondary level. "Building Regulations" mention that fire resisting shutter can be used as partition of fire compartment in those places where setting firewalls is not so easy. When using fire resisting shutter whose fire endurance doesn't include unexposed surface temperature rise, it should install closed independent automatic sprinkler system for protection on both sides, and the sprinkler sholud last at least 3 hours.
Q:Does anyone know about the A-level fireproof materials?
A1-level fireproof materials include: 1. inorganic materials: glass wool, rock wool, foam glass,etc. 2. organic materials: phenolic foam insulation composite board. I hope my answer can help you.
Q:What's the requirements of fire-fighting criteria of heat insulating material?
It shouldn't be under than B2 level. Roofing insulation fire rating requirements: the ministry of public security, housing and urban-rural development department issued about printing and distributing the civil building external thermal insulation system and the interim provisions on the exterior wall decorative fireproof prescribed in the notice: roof grassroots adopted duration of fire resistance is the non-combustible component that shouldn't less than 1.00 h's. Its roof insulation materials should not be below B2; Otherwise, the combustion performance of insulating material should not be below the B1 level. The junction of the roof and wall, the insulation layer around the opening part of roof should use the grade A thermal insulation material to set level fire-fighting belt that width is not less than 500 mm.
Q:Who knows the highest temperature the high-temperature refractory coating can resist?
When coating the fire-resistant coating on a steel beam of a building, paint film thickness reaching 2mm, and steel beams in the building are on fire, the fire-resistant coating can withstand for two hours. Fire-resistant coating is passive fire protection materials painted on the surface of the protected objects (eg. steel structure) , which can be divided into types of thick, thin, ultra-thin and facing according to the thickness. It can be divided into water-based and solvent-based products by medium. Whatever the structure of the building is, it will collapse if it is on fire for a long time. Fire-resistant coating function as isolation layer on the surfaces of the protected objects, delaying the building collapse time to win over valuable time for rescue and fire fighting. I hope this answer can help you.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range