8.7/10kV,8.7/15kV PVC,3c185m2unarmoured power cable,elctrial cable wire

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
200 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

MV 8.7/10kV,8.7/15kV,Cu/XLPE/CTS/PVC

----unarmoured power cable

-----3x185mm2,3x185sqmm

 

XLPE insulated PVC sheath  power cable

Conductor:copper(aluminum is also ok!)

Insulation:XLPE

Nominal voltage: 8.7/10kV,8.7/15kV

Sectional area:3cores x 185sqmm,3cores x 185mm2

Armoured or not:Not

CTS:Copper Tape Screen

Sheath:PVC

 

Used for power transmission and distribution line with voltage rated at 35kV and below.In comparison with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working

The standards

The power cable is mainly complying with IEC 60502,IEC60840 standard,  also can be produced according to OEM requirements and other standards, such as BS, DIN, ASTM, VDE, NFC standards, and so on.

 

PS:We can also manufacture as follows

 

 

Medium voltage cabel power cable:

3.6/6kV,6/6kV,6/10kV,8.7/10kV,8.7/15kV,12/20kV,18/20kV,18/30kV,21/35kV,26/35kV.

 

XLPE insulated PVC sheathed power cable (XLPE/PVC Cable)
XLPE insulated steel tape armored PVC sheathed power cable (XLPE/STA/PVC Cable)
XLPE insulated steel wire armored PVC sheathed power cable (
XLPE/SWA/PVC Cable)
Flame retardant XLPE insulated PVC sheathed power cable (FR/XLPE/PVC Cable)
Flame retardant XLPE insulated steel tape armored PVC sheathed power cable (FR/XLPE/STA/PVC Cable)
Flame retardant XLPE insulated steel wire armored PVC sheathed power cable (FR/XLPE/SWA/PVC Cable)

 

 

 

PVC insulated PVC sheathed power cable (PVC/PVC Cable) NYY cable
PVC insulated steel tape armored PVC sheathed power cable (PVC/STA/PVC Cable)
PVC insulated steel wire armored PVC sheathed power cable (PVC/SWA/PVC Cable)
Flame retardant PVC insulated PVC sheathed power cable (
FR/PVC/PVC Cable)
Flame retardant PVC insulated steel tape armored PVC sheathed power cable (FR/PVC/STA/PVC Cable)
Flame retardant PVC insulated steel wire armored PVC sheathed power cable (FR/PVC/SWA/PVC Cable)

Conductor long-time  operating temperature is 90 degrees. 

In short circuit, conductor  highest temperature should be not more than 250 degrees.  

 

Generally specs:

Number of the cores:Single core and 3 cores 

Conductor:copper or aluminium   

Insulation:XLPE 

Copper tape or copper wire screen  

Unarmoured and armoured(Steel tape and steel wire armored) 

PVC or PE sheath power cable

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between a pre-branch cable and a punched clip?
The structure of the PV cable is shown in the table. The difference between the ordinary cable and the PV cable is analyzed: The common cable can be seen from Table 1 that the conductor and the PV cable used are consistent. ordinary cable insulation and sheath can be seen from Table 1 different from the photovoltaic cable. Ordinary cable is only suitable for use in general environment. the advantages of photovoltaic power cable: high temperature, cold, oil, acid and alkali salt, anti-ultraviolet, flame retardant, environmental protection, photovoltaic power cable is mainly used for harsh environment, the service life of more than 25 years.
Q:Power cable inspection, how many meters should be sampled?
meaning: ZR represents the flame retardant properties YJ said cross-linked polyethylene insulation V said PVC jacket ZR-YJV table red copper core XLPE insulated PVC sheathed power cable 4 * 70 + 1 * 35 said 4 core 70mm2 + 1 core 35mm2
Q:Hello, ask about how to charge the electric car at home, use a few square millimeters of wire? How high is the demand for family lines, thank you!
What is the current good computer configuration on the market? The price of 4000 yuan or so no more than 4000 assembly parts to write down the price Thank you.
Q:A sub-eight splitter, behind the link ONU equipment, which also need to add fiber patch panels, or can be directly connected?
Cable and 10kV power line parallel laying the minimum distance of 0.5 meters.
Q:Power cable 5-color line, respectively, what color, what role?
YJ: XLPE insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated voltage: 8.7 / 15 kV (phase voltage 8.7 = 15 / 1.. line voltage 15kV) 3 * 300: Three conductor cross-section of 300 square copper conductor Another: If YJLV is the aluminum core. Here is not marked what the material is conductor, you can default to copper conductor.
Q:Choose the configuration of good or bad computer graphics card memory processor, etc., how to choose a different manufacturers
Calculation method: the amount of engineering calculation formula: L = (pipe length calculation + wire reserved length) × with the number of cross-section wire. Note: plastic pipe should not be flattened, cracks, no debris in the tube, cut the mouth should be flat, the nozzle should be shaved plastic wire pipe connection using glue bonding, plastic pipe bonding must be tightly tight, and in the pipeline plug on the plastic pipe plug, to prevent the paddle, plug tube concrete floor, wall and brick structure of the various switches, socket bottom box , The lamp junction box and the pipe connection must be connected with the wiring, is strictly prohibited plastic pipe directly into the junction box dark in the concrete junction box requirements with wet cement paper or plastic foam filled with internal, not allowed to use The cement paper packs its outside. Embedded in the floor, the shear wall of the plastic pipe, the junction box should be fixed firmly to prevent the shift
Q:Power cable casing buried what are the requirements
2 no protective measures, should avoid the termite damage zone, heat source and vulnerable to external damage to the section
Q:What is the wiring principle in the home improvement circuit?
Section 4 "Downhole Cable" Article 466 No cable should be laid in the total return airway and the dedicated return airway
Q:Power cable YJV22-8.7 / 15kv-3 * 300 what meaning
Strictly speaking is not in line with the norms. Special signal lines may be subject to interference
Q:Wire inside the two lines, red and black, black line is the line of fire or zero line ah?
According to the size of the product to open a good plastic mold and then purchase the plastic raw materials to be injected (raw materials depending on your product requirements, advanced point will use To the engineering plastics PE, PS, etc, and even to join the flame retardant, fiber material), the difference is like now with the charger on the use of only PVC3 Called the wire manufacturers according to your request to do a good line Of course, you have the conditions you can pull the wire of their own beer process: mold on the machine (ingredients test mode) --- welding wire and hardware (pin) --- then put the welding hardware on the mold (according to the mold Put five to ten range) - boot molding - detection of another: If you want to have all the country's certification, it is estimated that you no technology is not too, you can not buy that hundreds of thousands of equipment to detect The power line in the material composition and a variety of techniques to wear flattened Fenbao match platinum standard, because the formal power It is too much to be recognized, but you want to do ordinary DC line, such as mobile phone charger or no problem, but the regular factory what automation machine to do, then I do not know, but it is automated machine estimates But also the cost of scary Anyway, ordinary manufacturers do have any questions can EMAIL: qingxinghe@21cncom Do not call me in Google, I rarely said so much, add points to me, huh, huh

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range