Product Description:

Nominal
Cross-
sectional
Area of
Cable
Nomin-
allnsul-
ation Th-
lckness
She-
ath Th-
lckness
Approx
Quter Dl-
ameter Ofc-
able
Approx
Weight
of
Cable
D.C
Realstance
of Cable
at 20°C
A.C Reals-
tance at
Operating
Temperature
CuALCuALCuALCuAL
mm²mmmmmmmmkg/kmkg/kmΩ/KmΩ/KmΩ/KmΩ/Km
253.42.448.048.0319027160.7271.2000.92711.5385
353.42.550.050.0373130680.5240.8680.66831.1130
503.42.653.053.0439634990.3870.6410.49360.8220
703.42.757.057.0519838720.2680.4430.34200.5681
953.42.962.062.0635045510.1930.3200.24650.4105
1203.43.065.065.0725749840.1530.2530.19560.3247
1503.43.169.069.0838355420.1240.2060.15880.2645
1853.43.272.072.0974162370.09910.1640.12720.2108
2403.43.378.078.01185473090.07540.1250.09720.1609
3003.43.484.084.01486191780.06010.1000.07800.1290
4003.43.590.090.017868110470.04070.07780.06160.1010
5003.43.696.096.029875129160.03660.06050.04890.0789



Oparat-
ing Cap-
acity
Cable
induction
Reactive
impeda-
nce of
Cable
Positive
Negative
Sequence
impedance
Zero Sequence
impedance
Short-circuit
Current
CuALCuALConductorScreen
Cu
tape
Cu
Wire
Cu
tape
Cu
Wire
CuALCu
tape
Cu
Wire
uF/KmMH/KmΩ/KmΩ/KmΩ/KmΩ/KmΩ/KmΩ/KmΩ/KmKAKAKAKA
0.19220.37970.11920.93471.54313.51592.22964.12722.84073.692.422.958--
0.21160.36130.11340.67801.11883.25721.97383.70172.41825.153.372.958--
0.23670.34230.10750.50530.82903.08241.80103.41062.12917.314.792.958--
0.26930.32320.10150.35680.57732.93071.65123.15681.982310.26.682.958--
0.29990.30920.09710.26510.42192.83521.07622.99911.239913.89.682.958--
0.32660.29920.09390.21720.33822.78441.02622.91331.155117.411.42.958--
0.35700.28070.09100.18340.28002.74760.99022.85321.095821.714.22.958--
0.38730.26170.08850.15540.22892.71610.73002.79950.813426.717.52.958--
0.42900.27260.08560.13010.18272.31940.69992.38080.763434.622.63.031--
0.47060.26510.08320.11480.15412.29840.68242.34900.733443.126.23.031

--

0.53110.25640.08050.10230.12992.28250.66702.32130.706357.437.63.031--
0.58390.25030.07860.09360.11232.27020.65522.27950.685171.747.03.031--


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:W22 in the cable on behalf of what
Is the name of the vv22 it is armored copper core PVC insulated power cable V is PVC, VV said PVC insulated PVC sheathed, insulation and sheath is two different things, the jacket is the outermost layer of the cable, Insulation, mainly from the role of protection cable, the insulation layer is wrapped in the conductor outside the layer, mainly from the insulation. 22 means armored, armored between the sheath layer and the insulation between the strip, and its role is to strengthen the protection of the cable, at the same time, can prevent the mouse bite, can also be used as ground. The copper core is not shown in the letter in the model, because most cables are copper, so the copper cable basically takes its representation (indicated by T). On the contrary, if it is aluminum core cable, it will be added in the model L said aluminum core.
Q:Which has, know the power of the electrical, choose the cable formulas. And explain it
Basically are refining, the wax is also used, the high cost of particles
Q:PVC pipe line 6 points and 4 points which big ah?
Look at the chassis of the internal power supply is not connected to your power interface to see how many mouth ~ there is a 4-port square of the additional power socket to see there is no link that is what the link method is generally written on the motherboard ~ The word is a small look carefully ~ Corresponding to the chassis of the various plugs to see if there is no wrong plug (but the general can not start too much Gibel error) can be observed by the power indicator light (light) and observe the hard disk indicator Red (flashing) to determine the right or wrong line. There is only listen to the warning sound, the boot will be crisp ring, if there is proof of plug, there is no relationship in fact because there is no alarm, hdd hard drive, led + - white green two-wire power instructions, the above said three lines Do not plug can also be a normal boot, as long as it pw power plug can be a ~ rw restart does not affect the boot
Q:Why does the sparrow stand on the wire without electric shock?
the network patch panel is now more mainstream network system patch panels, generally every 1U height can accommodate 24 8-core network port, back line, front jumper plug in addition, look at the Google Encyclopedia on the 110 patch panel instructions, found a little problem, that is 110 patch panel documents, but the picture is not 110 patch panels, that should be called Kelon, we also Called this thing for the VDF, it should be noted that the 110 system is AT & amp; T, that is, Lucent (Lucent) company's standards, and Kelon is the German Kelon (kelone) company's standard, not the same thing, Dragon frame is generally used in large-scale voice wiring system, and generally fixed for the wall, if placed in the standard cabinet will have to install the backplane, the Kelon frame steel frame fixed on the backplane The 110 patch panel is a standard 19-inch equipment, can be directly fixed in the standard 19-inch cabinet As the 19-inch standard cabinet has been widely used in the civilian areas, so Kelon is now less application, mainly in the use of operators these with a number of tattoo and fat ancient mix of full-chip cable is integrated wiring system in the most basic connector, the product range is also very much on the market, of course, there are many changes in the form On the use of network patch panels and 110 patch panels, Google Encyclopedia and the library have a detailed description, you can refer to
Q:Why my home analog TV connected to the digital TV set-top box after the screen is black and white
The middle is to connect the two cables together, the terminal is connected to the equipment
Q:What recycled rubber is suitable for the production of wire and cable?
Symmetrical receptacles need to be treated differently, with color distinctions most convenient.
Q:The difference between the instrument cable and the low voltage power cable
In this only said home improvement commonly used, the pipe is basically direct, elbow, tee, the price is 5 points / only.
Q:Water and electricity installation drawings in the kz on behalf of what material of the threading tube
Color line, HDMI cable, S-terminal line of the three transmission video signal (HDMI can also transmit audio signal); coaxial line is the transmission of audio signals
Q:How to determine whether the square of the cable is standard
Horizontal laying of the cable within the cable, generally do not need fixed, natural laying can be. Vertical laying section of the cable within the bridge, with the need to match the line card, the use of tied rope (multi-purpose single insulated wire) one by one fixed cable, fixed spacing should meet the requirements. According to the control cable and the power of the different layers of laying, if the power cable to be multi-layer need to have 300mm spacing (or load capacity is large enough), if it is control cable, casually laying, if the laying of power cable laying below Layer, above the laying of control cable, but not too much affect the power cable cooling. If the high-voltage cable and low-voltage cable in principle do not allow common laying.
Q:Wire inside the two lines, red and black, black line is the line of fire or zero line ah?
If you buried the VGA line core has more than 7 (set the exclusion of the moxibustion smoked smoked ship to remove the shield), you can. VGA head is 5 to 10 feet welded together to do the public, red, green, blue shielded wire twisted together to receive the public ground: ..3 feet connected red, green, blue core; ; 14 white lines; outer shield pressure to the shell. (At least two) at both ends to pick out the audio line (left and right channels), shield to do the public, to access the audio 3.5 straight plug. If only one rich, on the channel to listen to listen to mona channel it

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range