Product Description:

Specifications

3kW frequency and voltage stabilizer converter/inverter AC50-11030 single-phase 
1.Reliability 
2.Interface-friendly

3kW frequency and voltage stabilizer converter/inverter AC50-11030 single-phase

 

Product Discription

The power adopts advantaged SPWM IGBT high-frequency inverter technology, internal structure is AC-DC-AC, thoroughly eliminate the network interference, output waveforms are pure. It has the following features: wide range of constant-voltage and constant-frequency, high precision, light weight, small capacity, output transformer with apartheid, with the good with a high quality uninterrupted power supply system.

1.Input voltage: 130~280V
2.Input frequency: 30~70Hz 
3.Output voltage: 220V/380V±0.5% 
4.Output frequency:50Hz±0.01% 
5.Wave distortion: <1%
6.Isolation transformer output, safe and credible
7.Auto-protection and alarm for output overvoltage, over current, overheat, short circuit
8.Efficiency reach above 90% ,widely applicable load,for nasty, capacitive resistance,any combination of the load

Product Parameter

 

Model

11005

11010

11030

11050

11100

31150

31200

313000

31450

311000

Capacity(VA)

500

1K

3K

5K

10K

15K

20K

30K

45K

100K

Output currency

2.1

4.2

12

21

42

63

84

125

188

420

Circuit model

IGBT/SPWM pulse width adjustment mode

AC

Input

Voltage

130V-280V

265V-495V

Frequency

30-70Hz

Phase

single phase

three phase four wire

AC output voltage

220V±1%

Output frequency

50Hz/60Hz

frequency stability

≤±0.01%

Voltage stability

≤1%

Wave distortion

≤2%

Reaction time

≤2mS

DPI (dots

per inch )

frequency meter

0.1Hz

Voltage meter

0.1V

Current meter

0. 1A

Power meter

0.1W

Efficiency

efficiency more than 90% ,be suit for wide-load, can be for the inductive, capacitive, resistive, and any mixed loads.

Protection function

The importation of non-fuse switch, without output  fuse switch, the electronic circuit to detect over-voltage Express .Over voltage, over current, over temperature, over load, short circuit, and automatic alarm.

Insulation reactance

500Vdc 20MΩ

Pressure endurance insulation

1500Vac/5mA/1min

Cooling model

Compulsive fan cooling

Working temperature

-10℃-45℃

Relative humidity

0-90%(No condensing)

Altitude

1500meters

Dimension (W×L×H)mm

410*440*135

460*440*220

560*350*600

660*400*700

830*450*1100

1160*520*

1370


FAQ

What is the delivery time?

We can delivery the equipment within 5 days after receiving your payment.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Abb inverter s510 with water circulation pump why the motor fever. The motor is 2 pole
Whether the motor is abnormal roar, if any, you can adjust the inverter parameters in the motor carrier frequency
Q:Three sets of batteries (540V) DC power supply U / f inverter.
It is estimated that the battery should be string - and - series connection method, and then rectifier part of the converter (which may also be caused by the switch) is actually a series of diodes in series, positive and negative after the reverse is actually the battery is Negative shorts, resulting in burning, as to burn only one of the group of a few cells, it should be string - and - string and that group, because the parallel to bear it double voltage.
Q:How to choose a Siemens inverter for a 5.5KW three-phase motor (2 pole)?
Beijing easy to create a website with Siemens inverter selection manual! You can log on online! Or contact them directly, they will give you professional answers!
Q:6-pole motor, speed 8000 rpm, corresponding to the frequency converter output frequency is how much?
The synchronous speed of the motor is n = 60f / p P is the pole pair number, and f is the power supply frequency. The pole pair number of the 6 pole motor is 3. Therefore, f = n * p / 60 = 8000 * 3/60 = 400Hz.
Q:Laptop power adapter how to detect?
No voltage output when no load.
Q:18: 5 kilowatts bipolar multi-pole pump motor with inverter
Under normal circumstances, with 15KW inverter on it.
Q:Laptop adapter heat
In fact, as long as the power adapter temperature is within the design range, that is, the temperature in the normal range, the general is not dangerous! So why is the power supply hot? What kind of temperature range is the normal range? Switching power supply conversion efficiency can only reach 75% -85% or so. The answer is here. Switching power supply conversion efficiency is high enough, it is still difficult to find a better way to convert. Switching power supply in the voltage conversion, a part of the energy loss, in addition to a small part of the loss in the form of waves, the majority of the way out of the heat. Switching power supply power is missing, the loss of energy is also missing, the power of the heat is also large. This is why the desktop power supply to add a fan for cooling reasons. We may wish to count, a 100W switching power supply, in the use of how much energy loss in the above!
Q:Yasukawa inverter reported bb code that is the reason why the base blockade?
This is not a fault! Only after the inverter receives the base block signal, it is not output!
Q:What is the difference between the electronic governor and the frequency converter on the motor speed regulation?
Electronic governor is for single-phase motor, by changing the access winding resistance and capacitance to adjust the motor speed, the speed of the power supply power for the output does not change, so this speed is not an energy Type of speed control methods, such as home for the use of fans and the like. Inverter speed is the original direct input three-phase asynchronous motor power first access to the inverter, in the inverter through the PWM and other electronic converter technology to rectify the frequency AC, inverter, become a frequency controllable AC In the input to the motor, in the motor running through the V / F control, output torque control, vector control and other control methods to adjust the frequency, change the loop current, to achieve energy-saving operation, especially in the light load energy efficiency is obvious, An energy-saving products that have been widely promoted and applied
Q:ABB frequency converter and the difference between domestic frequency converter
The objective lens is equivalent to the lens of the projector, the object is inverted through the objective lens, magnified real image. Eyepiece is equivalent to the ordinary magnifying glass, the real image through the eyepiece into a positive, magnified virtual image.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range