• 3KW Frequency and Voltage Stabilizer Converter/Inverter AC50-11030 Single-Phase System 1
  • 3KW Frequency and Voltage Stabilizer Converter/Inverter AC50-11030 Single-Phase System 2
3KW Frequency and Voltage Stabilizer Converter/Inverter AC50-11030 Single-Phase

3KW Frequency and Voltage Stabilizer Converter/Inverter AC50-11030 Single-Phase

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
10 unit
Supply Capability:
100 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

3kW frequency and voltage stabilizer converter/inverter AC50-11030 single-phase 
1.Reliability 
2.Interface-friendly

3kW frequency and voltage stabilizer converter/inverter AC50-11030 single-phase

 

Product Discription

The power adopts advantaged SPWM IGBT high-frequency inverter technology, internal structure is AC-DC-AC, thoroughly eliminate the network interference, output waveforms are pure. It has the following features: wide range of constant-voltage and constant-frequency, high precision, light weight, small capacity, output transformer with apartheid, with the good with a high quality uninterrupted power supply system.

1.Input voltage: 130~280V
2.Input frequency: 30~70Hz 
3.Output voltage: 220V/380V±0.5% 
4.Output frequency:50Hz±0.01% 
5.Wave distortion: <1%
6.Isolation transformer output, safe and credible
7.Auto-protection and alarm for output overvoltage, over current, overheat, short circuit
8.Efficiency reach above 90% ,widely applicable load,for nasty, capacitive resistance,any combination of the load

Product Parameter

 

Model

11005

11010

11030

11050

11100

31150

31200

313000

31450

311000

Capacity(VA)

500

1K

3K

5K

10K

15K

20K

30K

45K

100K

Output currency

2.1

4.2

12

21

42

63

84

125

188

420

Circuit model

IGBT/SPWM pulse width adjustment mode

AC

Input

Voltage

130V-280V

265V-495V

Frequency

30-70Hz

Phase

single phase

three phase four wire

AC output voltage

220V±1%

Output frequency

50Hz/60Hz

frequency stability

≤±0.01%

Voltage stability

≤1%

Wave distortion

≤2%

Reaction time

≤2mS

DPI (dots

per inch )

frequency meter

0.1Hz

Voltage meter

0.1V

Current meter

0. 1A

Power meter

0.1W

Efficiency

efficiency more than 90% ,be suit for wide-load, can be for the inductive, capacitive, resistive, and any mixed loads.

Protection function

The importation of non-fuse switch, without output  fuse switch, the electronic circuit to detect over-voltage Express .Over voltage, over current, over temperature, over load, short circuit, and automatic alarm.

Insulation reactance

500Vdc 20MΩ

Pressure endurance insulation

1500Vac/5mA/1min

Cooling model

Compulsive fan cooling

Working temperature

-10℃-45℃

Relative humidity

0-90%(No condensing)

Altitude

1500meters

Dimension (W×L×H)mm

410*440*135

460*440*220

560*350*600

660*400*700

830*450*1100

1160*520*

1370


FAQ

What is the delivery time?

We can delivery the equipment within 5 days after receiving your payment.

Q:Is the laptop power adapter AC and DC?
Notebook power adapter is not AC and DC. Power adapter is a small portable electronic equipment and electrical and electronic power supply conversion equipment, generally by the shell, power transformers and rectifier circuit, the working power for the exchange (China AC standard AC 220V), according to its output Types can be divided into AC (AC) output type and DC (DC) output type. General notebook power adapter are DC output, is the exchange of DC conversion equipment.
Q:Laptop power adapter bad what is the phenomenon?
Either the power is bad or the machine on the power supply module is bad to repair service
Q:My inverter is the era TVF8000 series, the motor is 15KW6 pole motor, has been used for 3 years.
If the frequency converter is selected according to the motor rated current, then the motor current exceeds the rated current, the inverter will become overcurrent protection In this case, that is, when the inverter began to select the amount of time to stay the lack of the same power, inverter general type than the fan pump type current capacity of a high grade If the inverter selection is no problem, then please see whether the inverter is working temperature is too high, too high will cause the electronic components to resist the decline in current. First, check the inverter to work the ambient temperature, the second Please check the inverter fan is damaged, clean down the inverter fan channel and fan to see if there is no plug
Q:Delta VFD-F frequency converter how to adjust the number of poles
P148 look, this is to correspond to the number of poles of the motor, not to adjust the number of poles of the motor
Q:Three-phase asynchronous AC motor speed control method
Second, the frequency control method Frequency control is to change the frequency of the motor stator power supply, thus changing its synchronous speed control method. Frequency converter system can be divided into AC - DC - AC inverter and AC - AC inverter two categories, most of the current domestic use - cross - frequency converter. Its characteristics: High efficiency, no additional loss during the speed control process; Wide range of applications, can be used for cage type asynchronous motor; Speed ??range, the characteristics of hard, high precision; Complex technology, high cost, maintenance and repair difficult. This method is suitable for applications requiring high precision and better speed performance.
Q:Huichuan frequency converter drag a 4-kilowatt four-pole motor to change the six pole can?
Change 6 will only be slower, the fan is no longer role. The frequency converter has a power parameter, as long as the motor is less than or equal to this power can be.
Q:Is the laptop power adapter hot?
Third, the power of the nominal voltage than my books the battery voltage is much higher, not an accident, right? First of all, to know is that the power supply to the books and the battery power supply to the notebook is different. Battery-powered, the battery output is pure DC, very clean, the battery voltage is neither possible nor need to design a high, lithium battery chemical properties determine a cell output voltage can only be about 3.6V, so Many batteries are used in three cascade way, 10.8V also became a very popular battery voltage. Some batteries are slightly larger than the integer value of 3.6V, such as 3.7V or 11.2V, etc., in fact, to protect the battery. Power supply, the situation is more complex, first of all need to add voltage to further regulation filter to ensure that the power performance is not very good in the case of stable work, the voltage regulator after the two parts of the city, all the way to the work of the power supply , The other way to the battery charge to the part of the power supply to the battery when the same power supply, and the part of the battery charge through the battery charge control circuit can be added to the battery, the control circuit can be very complex, so the power The voltage must be greater than the cell voltage to have sufficient capacity to supply the charge control circuit to the units. Finally the voltage actually added to the cell will never be the nominal voltage of your power supply. Rest assured.
Q:What is the application of variable frequency speed control?
Frequency control speed ratio is relatively large, in other words, the speed is accurate, smooth speed. Widely used, the basic works can be used
Q:Laptop power adapter output voltage is not the same as the current? What's the effect?
In the case of other conditions (rated output voltage, plug polarity, etc.) the same circumstances, the rated output current greater power adapter, can replace the rated output current is relatively small power adapter, which is not adversely affected. If the power adapter with a relatively small rated current is used instead of a relatively large power adapter with a rated output current, the power adapter will be "overloaded" and may cause damage to the power adapter.
Q:Why the number of motor poles increased, the inverter capacity will increase
The number of poles of the motor is not directly related to the rated current, but the number of poles is larger and the power factor is lower and the rated current will be higher.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords