• 3 NB Series Mud Pump Using in Oilfield with API Standard System 1
  • 3 NB Series Mud Pump Using in Oilfield with API Standard System 2
  • 3 NB Series Mud Pump Using in Oilfield with API Standard System 3
3 NB Series Mud Pump Using in Oilfield with API Standard

3 NB Series Mud Pump Using in Oilfield with API Standard

Ref Price:
get latest price
Loading Port:
Qingdao
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
50 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Item specifice

Theory:
Triplex pump
Pressure:
High Pressure
Usage:
Oilfield

1. Structure of 3 NB Series Mud Pump Description


The power end: The housing is welded steel-plate construction. It is stress-relieved after welding. The drive gears ate in volute type gears which allow smooth operation, high efficiency and long life. The crankshaft is a hollow one-piece steel casting. The power end is splash-Lubricate.

The fluid end: The suction and the discharge flanges conform to ASA and API specification.

The piston rod is connected with an intermediate rod by means of clamps to realize quick assembly & disassembly.

The valve seat bores have a bottom shoulders. The pistons and loners are lubricated and cooled by an independently spraying pump to have a longer service life.

Versatility in expendables



2. Main Features of 3 NB Series Mud Pump


1) Advanced test for quality 

2) MTC provided 

3) Good price and service


3. 3 NB Series Mud Pump Images


3 NB Series Mud Pump Using in Oilfield with API Standard

3 NB Series Mud Pump Using in Oilfield with API Standard

3 NB Series Mud Pump Using in Oilfield with API Standard


4. 3 NB Series Mud Pump Specification


Model

3NB500C

3NB1000C

3NB1300C

3NB1600/LN1600H

Power KWPS

368(500)

735(1000)

956(1300)

956(1300)

Strokes per minute pm

95

110

120

120

Stroke mm

254

305

305

305

Gear ratio

3.82

3.833

3.81

3.81

3.89

Speed of driving shaft r/min

363

423

457

457

467

Max. working pressure Mpa

30

35

35

35

51.7

Max. dia. Of liner mm

160

170

180

190

Dia. Of suction pipe mm

254

305

305

305

Dia. Of discharge pipe mm

100

100

100

100

Overall dim. mmL*W*H

4220×2640×2430

5170×2809×2530

5010×1942×1918

4450×2850×2077

5000×2850×2090

Weight kg

15940

21450

23000

29700

28345


5. FAQ of 3 NB Series Mud Pump


We have organized several common questions for our clients,may help you sincerely:


1) How about your company?

One of the leading manufacturers and suppliers specializing in this product in China, supply a wide variety of accessories consists of our one-stop sales. The integrated sales & service ensures customers with various demands an easier access for purchasing management.


2) How to guarantee the quality of the products?

We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance.


3) How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible.

Q:What are the functions of a disposable infusion pump?
When the transfusion is too slow, the dosage may not be enough, or the infusion time is prolonged unnecessarily, the treatment is affected, and unnecessary burden is added to the patient and the nursing work. In routine clinical infusion, the infusion of hanging bottle is generally used, and the speed of infusion is controlled by the use of a manual clamp. The speed of infusion is not easy to be controlled accurately, and the workload is great.Treatment of cancer patients with chemotherapy and critically ill patients need to make drug infusion rates constant, by adjusting the input speed and duration of chemotherapy drugs is continuously injected into the uniform, not only to achieve the best effect of chemotherapy, and to minimize the side effects of chemotherapy drugs.People suffering from diabetes need to inject a certain amount of insulin at a certain speed. The previous approach is basically a large dose of insulin injection, which not only caused a huge waste, and the effect of time is relatively short, so for a conveying device of flow and velocity control, to carry a small amount of drugs and precisely control the conveying speed and flow.Some special drug delivery to the elderly, children and physical weak, such as drugs, antihypertensive drugs, sodium nitroprusside (three TPN codehydrogenase) when the infusion rate and dosage should seriously control accurately, otherwise it will have serious consequences.
Q:What is the dry running protector of screw pump? What's the principle and function? Thank you
The utility model relates to a screw pump dry running protector, which is used for protecting the stator and the rotor of the screw pump from being transported by air
Q:Does the control cabinet of the fire control pump need to be related to the fire control room?
Automatic sprinkler, which is mostly used in this device or high water tank, the whole set of equipment must meet the most unfavorable point (the farthest the highest point of water) water pressure of the faucet.
Q:Does the reservoir water heater press the booster pump (high marks)?
If insufficient pressure really, adding an automatic booster pump in the water inlet, is feasible. Home booster pump, a basic model, to sell the place to ask the next to know, generally 200 yuan or so, traffic 0.3-1.8, 90~150 watts on it. Do not buy too large, too much power, the water will also be too large, but the water heater will not be used.
Q:What is the minimum continuous flow of a pump?
Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
Q:How to select metering pump head?
In metering fluoride, we recommend the use of Viton, sealed PVC pump head. For most chlorination applications, it is better to use EPDM sealed NP (plexiglass) pump head. For hydrogen peroxide mixtures, only PTFE sealed PTFE pump head or stainless steel pump head can be used
Q:What are the meanings of the vacuum pump, the front pump and the main pump?
The main pump and the front pump with the general vacuum unitThe front pump can be understood as a mechanical pump. It can be used by itself, but the pumping rate or the vacuum can not meet the requirements. In this case, we add a booster pump
Q:I would like to ask, constant pressure pump set pressure 20Mpa, the actual load is 15Mpa, then the constant pressure pump outlet pressure? If it is 20Mpa, then where is the loss of 5Mpa? If 15Mpa, the constant pressure pump 20Mpa how to understand? In addition, the constant pressure pump pressure is defined when the flow began to reduce the point, or a sharp drop in flow after the point?
15MPa. 20MPa means that if you enter the 20MPa, the variable mechanism will work, and the flow at this time automatically matches the load. 20MPa used to supply the fuel by maximum displacement.
Q:Water pump can not be pumped out, how to maintain water?
Packing overheating:Due to packing too tight, the cooling water can not enter the filler, or the shaft surface damage. Measures for proper relaxation of packing and cleaning of sealing pipe are adopted. Filler wear must be replaced with new ones. Before installation, soak in the oil and rotate it in turn. The incision should be staggered so that water leakage can be reduced. Fill the last lap after installed loading pressed to cover operation for further adjustment of the tightness.
Q:If you use an ordinary 15W submersible pump, put it in the tank, if the leakage, the fish will hang it?
What will happen then? The aquarium glass is an insulator. The water in the fish tank has the same potential as the live wire, and the fish is like a bird standing on the fire line. No electricity flows through their bodies, so they won't get electrocuted. But if you put your hands into the water, you will get an electric shock, because the line voltage through the water, then your body and the earth to form a loop, current flowing through your body you will get (of course, if you stand on the insulator does not get an electric shock)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords