3.6~36KV XLPE insulated copper conductor power cable

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
500 m
Supply Capability:
1000000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

3.6~36KV XLPE insulated copper conductor power cable

1.Factory price
2.international standards
3.fast delievery                 

Executive standard

International: IEC 60502-2, IEC 60228, IEC 60840, IEC62067

Chinese: GB/T 12706.1~12706.3-2008

Other standards such as BS,DIN and ICEA upon request

 

Applications

For laying indoors , in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force .

The product is suitable for use in power transmission and distribution lines with ra

power frequency voltage 3.6/6kv~26/35kv.

Operation characteristics

  1. Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv

  2. Max. admissible operating temperature of the conductor:90

  3. Max. short-circurt temperature of conductor shall not exceed 250.
    (5s maximum duration)

  4. The ambient temperature under installation should not below 0

  5. The bending radius of a single-core cable should not less than 20 times of the cable diameter.
    The bending radius of a three-core cable should not less than 15 times of the cable diameter.

Type of cable

Type

Designation

Application

YJV

Copper conductor, XLPE insulated and PVC sheathed power cable

For laying indoors , in tunnel or cable trench, unable to bear external mechanical forces. Single-core cable in magnetic duct is not permissible

YJLY

Aluminum conductor, XLPE insulated and PVC sheathed power cable

YJY

Copper conductor ,XLPE insulated and PE sheathed power cable

YJLY

Aluminum conductor ,XLPE insulated and PE sheathed power cable

YJV22

Copper conductor ,XLPE insulated, steel tape armoured and PVC sheathed power cable

For laying indoors , in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force

YJLV22

Aluminum conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable

YJV23

Copper conductor ,XLPE insulated ,steel tape armoured and PE sheathed power cable

YJLV23

Aluminum conductor ,XLPE insulated ,steel tape armoured and PE sheathed power cable

YJV32

Copper conductor, XLPE insulated, steel wire armoured and PVC sheathed power cable

For laying indoors , in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force .

YJLV32

Aluminum conductor ,XLPE insulated, steel wire armoured and PVC sheathed power cable

YJV33

Copper conductor ,XLPE insulated ,steel wire armoured and PE sheathed power cable

YJLV33

Aluminum conductor ,XLPE insulated ,steel wire armoured and PE sheathed power cable

Production range of cable

Type

Nomber of cores

Rated Voltage kV

3.6/6

6/6 6/10

8.7/10 8.7/15

12/20

18/20 18/30

21/35

26/35

Nominal cross-section of conductlr mm2

YJV
YJLV
YJY
YJLY

1

25-800

25-800

25-800

35-800

50-630

50-630

50-630

3

25-630

25-630

25-500

35-500

50-400

50-400

50-400

YJV22
YJLV22
YJY23
YJLY23

1

25-800

25-800

25-800

35-800

50-630

50-630

50-630

3

25-630

25-630

25-500

35-500

50-400

50-400

50-400

3

25-630

25-630

25-400

35-400

50-240

50-185

50-150

 

Workshop

 

Package & Shipping

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The wall was sideways opened a trough how to do ah?
The copper core grinding first to the copper core on the flux (rosin or solder paste)
Q:With a i3-2100 desktop computer about how much money. To have a separate graphics card. Give a configuration alone, no more than 4000
Can be buried, the general depth of 0.8 meters, the cable on the road to be added through the road.
Q:Power cable ZRYJV-4x70 + 1x35 What does it mean?
51 laying of cables 511 cable laying should meet the following requirements: 1 cable type, specifications should be consistent with the design requirements
Q:Power Cable Check Well b-type covers show what?
B-grade steel fiber concrete check covers are used for motor vehicle driving, parked urban roads, highways and parking lots C-grade steel fiber concrete check covers for slow lanes, residential quarters and sidewalks D-grade steel fiber concrete inspection covers for green belts and motor vehicles can not travel, parked lanes and venues
Q:What is the installation specification for the cable tray bracket?
You ask the question is the installation of the trough or concealed it? If it is installed that is the first line and then drill the drill hole with the impact of drilling holes after the new material with a new material. If it is concealed there is no such problem that is buried pipe buried in the wall on the line
Q:Ask you a question: how the computer CD-ROM power supply 5V and 12V two lines? Another audio and video cable which group?
Cable bridge at both ends to be installed across the ground wire, ground wire diameter can not be less than 16mm2. Wire ends and wire ends of the middle box to be installed at both ends of the ground wire, grounding wire diameter can not be less than 6mm2. Full length bridge with the grounding system connected to not less than 2. Cable bridge is divided into trough, tray and ladder-type, mesh and other structures, by the bracket, arm and installation accessories and other components. Can be set up independently, can also be attached to a variety of structures (structures) and corridor stent, reflecting the structure is simple, handsome in appearance, flexible configuration and easy maintenance features, all parts are required galvanized, installed in the building Outside the bridge, if it is in the vicinity of the sea or belong to the corrosion area, the material must have anti-corrosion, moisture resistance, good adhesion, high impact resistance of the physical characteristics. According to the relevant provisions of the specification, galvanized cable bridge for a good grounding. galvanized cable tray direct board each fixed bolt contact resistance should be less than 0.005Ω, then the cable bridge can be used as a ground trunk (dusting cable tray should not be used as a grounding line), the resistance of each cable bridge can be the following formula Calculate: r = ρ · L / S where: ρ = 15 × 10Ω-6 / cm (20 ℃); L = length calculated by 100mm; S = cross-sectional area of ​​cm2. The unit resistance value of the ladder on the pallet is shown in Table 2. The unit resistance value of the cable duct is shown in Table 3 The resistance of each ladder (or each cable slot) after the installation of the cable tray is the total: R = R (r + 1 / 3r ') where: R - ladder, that is, (cable trough) total length of the total resistance (mΩ); r - ladder unit length resistance (mΩ / m)
Q:Why my home analog TV connected to the digital TV set-top box after the screen is black and white
Our teacher wants us to do the thermometer, but I do not know what to do. The What materials should I use? The Whether my straw is now pressed and deformed, and adjust the water level, so that the water level is slightly higher than the bottle, with oil pen in the straw
Q:What is the difference between a trough bridge and a tray tray?
Many, with the cable where the requirements should be used bridge.
Q:What is the warranty period for wire and cable?
The state is 30 years warranty. But the specific warranty period according to the type of wire and cable and the use of conditions and temperature and applicable methods to determine.
Q:Copper core power cable laying cable sets what fixed
BTS is 2G base station, a wireless network consists of N BTS and several BSC, each BTS need to access the BSC through the transmission network. 2G base station transmission interface is mostly 2M interface. SDH (Synchronous Digital System), is a technical system developed by ITU, is a transmission technology. SDH line side (that is, out of the cable) is 155M, 622M, 2.5G, 10G optical interface. Branch side (then business network equipment, including base stations) are more than 2M, FE, GE also has 155M optical interface. DDF and ODF are patch panels, DDF digital patch panels, ODF fiber patch panels. SDH line side of the ODF frame, is received on the outgoing cable, DDF frame service network equipment, in the base station is then BTS. Set the patch panel is mainly for easy maintenance, you can label on the patch panel, each interface business type is very clear. The communication system diagram in the base station is this: BTS - DDF - SDH - ODF - another bureau.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range