• 3/3.3kV/6/6.6kV/10/11kV Compact AC VFD Drive System 1
  • 3/3.3kV/6/6.6kV/10/11kV Compact AC VFD Drive System 2
3/3.3kV/6/6.6kV/10/11kV Compact AC VFD Drive

3/3.3kV/6/6.6kV/10/11kV Compact AC VFD Drive

Ref Price:
get latest price
Loading Port:
Dalian
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
10000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 Working Principle

WLD-HVF series medium voltage inverter adopts Power Units in series and overlapping technology to obtain MV directly by means of overlap wave. Low voltage power unit is an actually improved motor variable frequency inverter, which takes full advantage of mature technology. WLD-HVF belongs to High-high voltage source inverter, the customer can connect high voltage (3/6/10KV) directly to WLD-HVF, then WLD-HVF output high voltage (3/6/10KV) correspondingly. WLD-HVF consists of phase-shifting transformer, power unit cabinet and controller, for example:

6KV Series: Consisting of 15 AC power units with 690V. Every 5 power units are connected in series to form one phase (phase voltage 3450V), 3-phase Y-type connection, so the Line voltage can reach to 6KV.


Energy Saving Fields

  • Power Generation: Induced draft fan, forced draft fan, condensate pump, feed pump, primary air fan, secondary air fan, booster fan, circulating pump, mill fan, slurry pump etc

  • Cement: draft fan, high-temperature fan, air blower, dust collection fan, grinding machine etc.

  • Metallurgy: blast furnace blower, slurry pump, feed water pump, dust fan, compressor etc.

  • Petroleum&Chemical: Water injection pump, crude oil pump, Compressor, fan, circulation pump, etc

  • Urban water supply: Water delivery pump, water intake pump, water supply pump, sewage treatment industry, self-fractionating pump etc

  • Minerals & Mining: Mud pump, ventilation fan, belt conveyor, slurry pump etc
    Others: Loads such as fan, pump and compressor in pharmaceutical, paper making and wind tunnel test

 

Patented pre-charge technology

The pre-charging function can effectively control the charging speed of the capacitors, and thus charging shock can be prevented. Together with IGBT intelligent driving technology, the innovations can double the lifetime of the capacitors, from 5 years to 10 years for instance. The maintenance cost can be lowered significantly. 

Patented automatic recovery technology

With real-time monitoring, the VFD system can identify the causes of power cell bypass, and automatically restarts once it detects the problems are fixed. It ensures equipment to operate continuously and stably when the bus power supply has instantaneous failure.

Patentedventilation and heat dispersion method

Our VFD’s ventilation system is centralized and vertical. It has significant advantage over the distribution type in terms of temperature field control, air flow distribution, and wind speed uniformity. Since the capacitor units are located at the ventilation ducts, it is estimated that the lifetime of capacitor can be doubled, and thus the overall system service time is prolonged with this cooling mechanism.

3/3.3kV/6/6.6kV/10/11kV Compact AC VFD Drive 

Q:What is the characteristic of the variable pole speed method?
Third, cascade speed control method Cascade speed regulation refers to the winding motor in the rotor loop into the adjustable additional potential to change the motor slip, to speed control purposes. Most of the slip power is absorbed by the additional potential in series, and the additional device is used to return the absorbed slip power to the grid or to convert the energy. According to the slip power absorption and utilization, cascade speed can be divided into motor cascade speed, mechanical cascade speed control and thyristor cascade speed form, the use of thyristor cascade speed, which features: The process of the slip loss back to the grid or production machinery, the higher efficiency; device capacity and speed range is proportional to the investment province, for speed range in the rated speed of 70% -90% of the production machinery; Device failure can be switched to full speed operation, to avoid shutdown; thyristor cascade speed power factor is low, the greater the impact of harmonics. This method is suitable for use in wind turbines, water pumps and rolling mills, mine hoists, extruders. Fourth, winding motor rotor series resistance speed control method Winding asynchronous motor rotor series into the additional resistance, so that the motor slip increase, the motor running at a lower speed. The greater the resistance of the series, the lower the motor speed. This method is simple and easy to control, but the slip power is consumed in the form of heat. Is a level of speed, mechanical characteristics of soft.
Q:I power adapter output current 3.25A for a 4.5A, can you use it
As long as the same voltage with the same polarity on the connector can! The The This can also increase the stability of the computer ^ _ ^, and to speed up the role of charging time, in short, will not cause a bad impact on the computer.
Q:What is the motor series parameter setting of the inverter? If it is with the spindle,
Ordinary inverter standard drive is a 4-pole motor, the greater the number of poles of the motor, the greater the rated current, the motor pole number is the frequency converter when the self-learning automatically set, in the vector control must be self-learning
Q:What is the meaning of the bipolar polarity in the inverter ah There is a +10V signal input is a -10V What is the meaning of ah?
That is to say that the potentiometer at both ends of the line between + 10v and -10v, tap can be given with a potentiometer to control the positive and negative!
Q:Variable frequency pump pressure in the very low flow instability, why?
. If you want to stabilize the pressure, you must adjust the pipeline characteristic curve is the work point to enhance, so that you can both stabilize the pressure and adjust the flow.
Q:Who knows how the frequency converter works
2. flat wave circuit In addition, the ripple current generated by the inverter also changes the DC voltage. In order to suppress the voltage fluctuation, the inductor and the capacitor absorb the pulsating voltage (current). In general, the DC voltage of the rectifier is rectified and the DC voltage is rectified. General inverter power supply of the DC part of the main circuit in terms of margin, so eliminating the need for a simple capacitor filter smoothing circuit.
Q:Laptop power adapter current is not the same alternative?
so the output voltage, the same output polarity, the output current of the adapter can be used in smaller power notebook, and small power adapter can not be used to give Powerful notebooks,
Q:Asus notebook power adapter how to open
if the power adapter is broken directly to the computer with a city on the line can not spend a few money back you can burn the computer is bigger to go to the computer The city took to repair and no one to repair to buy a very low price
Q:Is the laptop power adapter high temperature normal? Is there anything else?
Hello, the power adapter because there are a lot of electronic components so hot is normal, the general hand feels hot does not feel hot on it, if hot, then there is a problem.
Q:What are the types of power adapter used in notebooks?
The regulator wants the laptop adapter to not waste energy or add harmonics to the electricity lines. The first factor is that the adapter should plug the plug without any load, and it should be as small as possible to absorb power (standby). People are accustomed to the laptop adapter inserted in the socket, but not connected to the computer, the request can prevent the loss of this situation. The second factor is the recent requirement that it requires a specific average power efficiency at different load conditions (25%, 50%, 75%, and 100%) and is implemented by the global regulatory agencies in order to facilitate compliance with the specification And reduce overhead costs. Finally, the European and Japanese mandated reduction harmonics requirements have been applied to laptop power adapters because they have exceeded these standard specifications for the 75 W input power threshold. In a sense, the mobile / universal features of the laptop adapter make it the first mass production power product subject to the IEC1000-3-2 specification.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage