3*240mm. Copper Conductor Underground Cable

Ref Price:
Loading Port:
China main port
Payment Terms:
TT or LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Brief Introduction

1.Certificate:ISO,CE,SONCAP,UL
2.Asia,South Americ,Africa
3.fast delievery&reliable quality

3*240mm2 copper conductor underground cable

 

 1 Specifications

XLPE/pvc Insulated, PVC/PE Sheath
IEC 60502, IEC 60228, IEC 60332

Armour, LSZH, Fire-resistant optional

 

 

2 Constructions

Conductor

Compact Stranded Copper Conductor, Class 2 as per IEC 60228

Circular solid Copper Conductor, Class 1 as per IEC 60228

Flexible Stranded Copper Conductor, Class 5 as per IEC 60228

Conductor Screen

Semi-conductor (MV only)

Insulation

XLPE(Cross-linked polyethylene)

Insulation Screen 

Semi-conductor (MV only)

Separate Screen 

Copper Tape (MV must, LV optional)

Filler

PP Yarn, or Paper

Wrapping Tape

PP

Inner Covering

Extruded PVC (MV only)

Armour

Steel Wire, or Steel Tape, or Aluminium Tape optional

Overall Sheath

PVC or PE

 

3 Applications

Used for power transmission and distribution line with voltage rated at 35kV and below.Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.

 

4 Standards

International: IEC 60502-2, IEC 60228

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request 

 

5 Technical data

Rated voltage: 0.6/1kV, 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp.  0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

                    15 x cable O.D for single-core armoured cables

                    15 x cable O.D for multi-core non-armoured cables

                    12 x cable O.D for multi-core armoured cables

 

6 Certificates

CE, RoHS, CCC and more others at request

 

7 Images

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Will the two 16 square copper wire with what specifications of the trunking
How to say that interference is certainly some, if you line less words on one or two in the bridge next to do a tube it! The pipe will be a little better. Upstairs that I do not think that although in practice the construction of this practice a lot, because you do not feel the interference, but the reality does interfere with, or science should not be strong and weak must be separated.
Q:Power cable inspection, how many meters should be sampled?
meaning: ZR represents the flame retardant properties YJ said cross-linked polyethylene insulation V said PVC jacket ZR-YJV table red copper core XLPE insulated PVC sheathed power cable 4 * 70 + 1 * 35 said 4 core 70mm2 + 1 core 35mm2
Q:How long is the service life of the cable?
For corrosive environments, cable trays with suitable corrosion resistant coatings should be used
Q:Brief description of the difference between cable and cable.
Network cable is to take the digital signal, CATV cable is to take the analog signal, how can interfere with each other, do not understand do not see this stare blindly understand the beads. It was all right to be wrapped around with an electrical tape.
Q:What are the varieties of wire and cable (detailed point)
Chien fiber optic transceivers fiber optic cable flange fiber box fiber jumpers welding machine. Our company: Qin Sheng network
Q:What is the wiring principle in the home improvement circuit?
Section 4 "Downhole Cable" Article 466 No cable should be laid in the total return airway and the dedicated return airway
Q:Water and electricity installation drawings in the kz on behalf of what material of the threading tube
No, without this provision, the purpose of blocking the cable piercing is to prevent the outside world on the adverse gas and other reasons of the invasion, in fact, as long as the purpose is achieved, the material selected or look at the situation, such as coal mine perforation must be sealed , The reason is to prevent the wind and air leakage, as well as when the outside world when the explosion of the substation damage, as well as their own substation has a fire source to prevent the development of fire to the outside world
Q:Lighting wire, I do not know is it. The When to use BV1 * 2.5, when to use 2 * 2.5, when to use 3 * 2.5, when to use 4 * 2.5,
Why did not you take this time when you were installed or that it was only a detour
Q:How to determine whether the square of the cable is standard
Horizontal laying of the cable within the cable, generally do not need fixed, natural laying can be. Vertical laying section of the cable within the bridge, with the need to match the line card, the use of tied rope (multi-purpose single insulated wire) one by one fixed cable, fixed spacing should meet the requirements. According to the control cable and the power of the different layers of laying, if the power cable to be multi-layer need to have 300mm spacing (or load capacity is large enough), if it is control cable, casually laying, if the laying of power cable laying below Layer, above the laying of control cable, but not too much affect the power cable cooling. If the high-voltage cable and low-voltage cable in principle do not allow common laying.
Q:3 (WDZBN-YJV-4x240 + 1x120) cable how to interpret
In fact, this is a wrong model! (WDZBN-YJV-4x240 + 1x120) - 3 cables, each copper conductor Conductive cross-linked polyethylene insulated PVC sheathed halogen-free low smoke Flame-retardant fire-resistant power cable 4-core 240mm² + 1-pin ground protection line 120mm². As we all know, polyvinyl chloride is halogen-free, not "halogen-free". The correct model should be: 3 (WDZBN-YJE-4x240 + 1x120) - 3 cables, each copper conductor Conductive cross-linked polyethylene insulated polyolefin sheathed Halogen-free low smoke Flame-retardant fire-resistant power cable 4-core 240mm² +1 core grounding protection line 120mm². For more cable knowledge, please search for "Industrial Automation Integrated Cable Solutions" into the Industrial Network.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range