2PC stainless steel industrial floating water ball valve

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
150 PCS
Supply Capability:
1000 PCS/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

Solenoid valve series, specially used with water, liquid


Packaging & Delivery

Packaging Detail:40pcs/CTN; 60pcs/CTN
Delivery Detail:about 25 days for MOQ

Specifications

Solenoid valve series, specially used with water, liquid.

 

details

1. Description

 

Body material

Brass/ Nylon

Seal Material

NBR:0°C~80°C, EPDM:0°C~120°C, VITON: 0°C~150°C

Port size

1/8',1/4''

Port thread

G,NPT,PT

Orifice

1.6,2.2.2.5,3.0mm

Temperature

10°C to 150 °C

Medium

Air, water,steam etc.

Pressure

0-1.6Mpa

Voltage

DC-12V,24V,42V,

AC12V,24V,36V,42V,110V,220V/50HZ,

Latching type:DC6-24V,

others upon request

Tolerance

±10%

Coil

IP 65,100% ED

 

2. Picture

3. Production line

masoneilan control valves

4.Certificates

masoneilan control valves

5. Our service

We have more than 12 years experience in solenoid valves.

Excellent quality control is one of our main principles.

Our design, producing and testing are strictly complied with ISO9001 standard.

Now our products are being exported all over the world.

We provide OEM service, accept customer label, develop the product with your drawings or samples.

Any question, will be replyed within 24 hours.

 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to check the quality of the valve?
First, visual inspection of the valve appearance, followed by a spectrometer to check the material, material, and then look at the hydraulic test pressure, whether there is leakage.
Q:What does the J41Y-100I valve type mean?
Stop valve typeJ represents the cut-off valve, 4 (flange) on behalf of his connections, 1 (straight) on behalf of his structure, Y (seal) on behalf of his seat sealing surface or liner material code, 100 is the nominal pressure value, I (chrome molybdenum steel) is the code of the body material
Q:Ketem valve relative to other valve companies in the industry what are the advantages?
The electric actuator built-in servo system, no need to add servo amplifier, input 4-20mA signal and 220V AC power supply can control the operation. Compared with the ordinary electric ball valve, the utility model has the advantages of compact structure, small size, light weight, close distance between the valve seat and the end face flange, less material retention, superior sealing performance, etc..
Q:What does the whole copper valve mean?
Industrial oxygen pipes on the valve are all copper valve, hand wheel is not. The market had had 4 6 1 inch screw valve also has a lot of full copper. The tap also has all brass. The valve body and the inside are all copper.
Q:How do you calculate the pressure difference between the front and rear of the valve?
Well, it's not easy. And you do not give the specific structure of the valve, so there is no way to talk about the calculation. The simplest way is to install the pressure gauge and the flow meter on both ends of the valve, and read the data directly.
Q:How to use current to control valve opening and closing?
You don't know if the precision requirement of high precision can be used for high requirements of valve control valve (4-20mA) control but need converter needs the temperature signal into your current signal control valve (4-20mA) valve door factory will not have this thing you can ask to do control system manufacturers (in tell you part of the valve switch and adjust the price of at least 1000 points (OH) to not give me angry) is something you can ask me the valve factory
Q:What is the difference between the valve before the pump and the valve after the pump?
Before the pump few valves, up to a foot valve, pump valves, convenient maintenance, then the most important is that the action of check valve backflow, water hammer....
Q:Why can't the clip type check valve be directly connected with the pipe mouth or other valves?
The clip type check valve is made up of two discs to prevent backflow.If the clip check valve is connected to the other valve, the disc may touch the valve and cause the check valve not to be fully opened or closed. This is a preliminary analysis of "enter the valve", for reference only!
Q:1/2, what does 1/4 valve mean? I don't understand. What does this number mean?
1/2 is 4 points caliber, =15mm 1/4 is 2 points, caliber concise
Q:How big valves are used in the DN90 pipeline?
If you use a 97 tube, the inner diameter of 89- phi 90., nominal pressure is low, then try to use DN80, DN80 valve diameter of 80, you can try butt welding

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range