Description of 22KW Vector Control Converter Frequency
22KW Vector Control Converter Frequency is a high-quality, multi-function, low-noise variable frequency drive which is designed, developed and manufactured according to international standards. It can meet different needs of industrial conditions.The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse
Features of 22KW Vector Control Converter Frequency
1).Adopts 16 bit microprocessor, sine wave PWM control
2).Automatic torque ascension and automatic sliding compensation function
3).Output frequency 0.1-400 Hz
4).8 period of speed setting and 7 period can be running the program
5).Low noise, carrier frequency can from 1 kHz-15 kHz adjustment
6).Two paragraphs Acceleration and deceleration time and two segments of the S Curve slow and deceleration
7).Simulation frequency set acceptable 0-10 VDC, 4-20 mA
8).The built-in serial communication interface RS-485(baud rate can reach 38400)
9).Save energy running and automatic voltage stabilizing section function (AVR)
10).Adjustable V/F curve Acceleration and automatic and deceleration function
11).Simple vector control and built-in PID control, and the simple positioning function
12).Sleep/wake up function and zero velocity keep function
Structure of 22KW Vector Control Converter Frequency
Application of 22KW Vector Control Converter Frequency
★Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.
★Plastic: extruder, hauling machine, decorating machine, etc.
★Pharmacy: mixer, roaster, etc.
★Woodworking: engraving machine, sander, veneer peeling lathe, etc.
★Papermaking: single type papermaking machine, etc.
★Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.
★Printing: cloth-washing machine, dye vat, etc.
★Cement: feeder, air blower, rotary furnace, mixer, crusher, etc
★Fan and pump: kinds of fans, blowers and pumps
Performance of 22KW Vector Control Converter Frequency
Item | Specification | |||||||
Input | Rated voltage | T4 series: Three phase 380v, ±15% | ||||||
Frequency | S/T2 series: Three/single phase 220V, ±15% | |||||||
50/60Hz ±5% | ||||||||
Output | Voltage | T4 series: Three phase 0-380V | ||||||
Frequency | S/T2 series: Three phase 0~220v | |||||||
0-400Hz | ||||||||
Overload ability | 150% rated current for 30s; 180% rated current for 1s; | |||||||
Dissipation | Cooling type | Forced Cooling | ||||||
Temperature protection | Heatsink temperature >85℃ trip protection against overheat | |||||||
Fan control | Heatsink temperature> 50℃, fan forced operation, frequency inverter continue work | |||||||
Control | Control mode | Open-loop vector control, V/F control | ||||||
Performance | Start torque | Open-loop vector control: 0.5Hz 180%; | ||||||
VF control: 0.5Hz 150% | ||||||||
Speed range | Open-loop vector control:1:150; | |||||||
VF control:1:100 | ||||||||
Speed control precision | Open-loop vector control: ±0.2%; | |||||||
VF control:±0.5% | ||||||||
Function | Channel of operation command | Keyboard control,terminal control,communication control | ||||||
Start mode | Direct start, DC injection braking before start, speed tracking before start | |||||||
DC injection braking | Start DC injection braking, stop DC injection braking | |||||||
Dynamic braking | Built-in braking unit | |||||||
Frequency source choice | Keyboard digital frequency setting, analog AVI setting | |||||||
PID control setting, telecommunications setting | ||||||||
Frequency resolution | Keypad setting:0.01Hz; Analog setting: 0.1% | |||||||
Carrier frequency | 1Khz~12Khz, | |||||||
Acc/Dec time | 0.1~6000.0s or 0.01~600.00s | |||||||
Signal | Analog input | AVI:0~10V | ||||||
ACI:4~20mA | ||||||||
Keyboard potentiometer input: 0~10V | ||||||||
Analog output | AFM:0~10V or 0~20mA, Select through JP1 jumper | |||||||
Digital input | A total of 28 kinds of function could be selected from S0 ~S5. | |||||||
Digital output | 1 channel open collector output(MO1-MCM) | |||||||
1 channel relay output( TA-TC normally open, TB-TC normally closed; | ||||||||
Communication Port | Communication protocol | Based on RS485 hardware, support standard MODBUS protocol. | ||||||
Display Functions | Four digital tube display | Can monitor the operation state of frequency inverter flexibly and conveniently. | ||||||
Installation | Humidity | Less than 90%RH | ||||||
condensation | ||||||||
Vibration | Less than0.6G | |||||||
Elevation | 0~1000m, reduce the rated specification 10% when lift 1000m for each. | |||||||
Storage temperature | -20~60℃ | |||||||
Structure | Defend degree | IP20 |
- Q:The parameters of the inverter is 4, 6 motor can be used
- Inverter parameters are 4, 6 motor can be used. Parameters can be changed, the general inverter has a special number of motor parameters set, as well as the motor speed settings, if the series can not be changed, put the speed out of the necessary amplification of the inverter to enlarge some.
- Q:How does the variable frequency motor output torque at very low frequencies?
- Low frequency, the motor torque is relatively low, generally VF inverter performance is good or bad, the price level reflected in this time. But there is torque to enhance the function, it will not move without moving. If no load can not start, check the motor card and other mechanical problems such as whether there is a problem.
- Q:The laptop's power adapter is broken how much it costs
- Hello, this is not very expensive Generally in 80 or so, you can go to the Internet to see the model, and then to the store to buy the price on it.
- Q:400w 6-pole motor should be equipped with much of the inverter?
- 400w 6-pole motor with frequency converter, as long as 1kw inverter can be a.
- Q:380V 2 pole motor can use the inverter?
- At the same time, the paint is thick, the best 2 times dipping Wiring with the end of the enameled wire end of the time, to use insulating materials separated better, more insurance
- Q:22kw.2 pole fan can use Fuji inverter?
- according to the rated name of the fan brand and the inverter rated current control, select the current value match, or slightly larger The
- Q:Asus notebook power adapter how to open
- if the power adapter is broken directly to the computer with a city on the line can not spend a few money back you can burn the computer is bigger to go to the computer The city took to repair and no one to repair to buy a very low price
- Q:Why G120 inverter to be equipped with 4-pole motor?
- On the upstairs that the motor parameters to be set on the possible, such as voltage, current, power, power factor, rated efficiency, rated frequency, rated speed, motor overload factor
- Q:How do I select a drive? Which brand is better
- ?11, the inverter drives the synchronous motor, compared with the power frequency power regulator, reduce the output capacity of 10% to 20%, the inverter's continuous output current is greater than the synchronous motor rated current and synchronous pull the current value of the unit value product. ????12, for the compressor, vibration and other torque fluctuations in the load and the hydraulic pump and other peak load case, if the motor in accordance with the rated current or power value of the inverter, then there may be due to peak current over-current protection Action phenomenon. Therefore, you should understand the frequency of the operation of the situation, select the maximum current than the maximum current output of the inverter. When the inverter drives the submersible pump motor, the rated current is greater than the rated current of the submersible pump motor because the rated current of the submersible pump motor is greater than the rated current of the normal motor. ????13, when the inverter control Roots blower, because of its large starting current, so select the inverter must pay attention to whether the capacity of the inverter is large enough. ????14, select the inverter, be sure to pay attention to whether the protection level with the scene to match. Otherwise the scene of dust, water vapor will affect the long-term operation of the inverter. ????15, single-phase motor is not suitable for inverter drive. Recommended Ampang letter converter, domestic brand, quality and stability, first-class service, trustworthy!
- Q:Lenovo g450 laptop power adapter specifications is what?
- Input: 100-240V ~ 1.5A 50-60Hz Output: 19V - 4.74A
1. Manufacturer Overview |
|
---|---|
Location | Liaoning,China |
Year Established | 2001 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America South America Eastern Europe Southeast Asia Africa Oceania Mid East Eastern Asia Western Europe |
Company Certifications | ISO9001 |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | DALIAN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b)Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
22KW Vector Control Converter Frequency
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1pc pc
- Supply Capability:
- 8000pcs per month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords