2014 New Generation Digital Ultrasonic Cleaner 2.5L, 120W With Digital Heated Lab Use Ultrasonic Cleaner

Ref Price:
Loading Port:
ShanTou
Payment Terms:
L/C,T/T
Min Order Qty:
1 Unit set
Supply Capability:
100 Units per Day set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Ultrasonic cleaner series are mainly used in laboratory ,stores and the industrial small batch operations for cleaning of clock words,glasses,jewellery,electronics,hardware,plastic ceramic parts,etc...

1. Incorporation of ultrasonic generator and cleaning tank,compact construction,resistance of acid and alkali,handsome and practical.

2 .Cleaning time and heater controlled by computer ,it can be set optional.

3. Digital display,visual presentation and easy operation.

4. Sealed housing,resistance of water and humidity.

 

 

Model Specification

GB-1500B

GB-2500B

GB-5000B

GB-10LB

Ultrasonic Power

65W

120W

140W

220W

Ultrasonic Frequencies

40KHz

40KHz

40KHz

40KHz

Heated Power

100W

200W

200W

200W

Tank Size(mm)
(length×width×height)

165×140×75

245×140×95

300×150×150

300×240×200

Product Size(mm)
(length×width×height)

190×160×270

270×170×270

355×180×320

325×265×370

Capacity(ml)

1500

2500

5000

10000

Weight(kg)

2.7

3.5

4.1

6.5

 

 

Okorder services for you

Ver.1

1. We will reply you in detail within 24 hours

2. We own well-trained and professional sales and after- sale services who can speak fluent English.

3. We offer OEM services and can print your own logo on products.

4. We have strong ability to do ODM projects.

 

Ver.2

1.7*24 hours Hotline & Email Service

2. Your inquiry related to our products or prices will be replied in 24hrs.

3. Well-trained and experienced staffs to answer all your enquires in fluent English

4. OEM&ODM, any your customized demand we can help you to design and put into product.

5. Distributor ship are offered for your unique design and some our current models

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Is the contact lens ultrasonic cleaner useful?
The eyes in the secretions of some large protein molecules into contact lens care solution, the decomposition of protease protein decomposition after the residue will be on the surface of the lens, so also need some physical forces pulled out, with ultrasound or finger radial clear lens, then rinse with nursing liquid
Q:What is the cleaning process of ultrasonic cleaners?
The effect of ultrasonic on the liquid, rupture of each bubble in liquid will produce great energy of shock wave, the equivalent moment of high temperature and high degree of hundreds of thousands of atmospheric pressure, this phenomenon is called "cavitation", ultrasonic cleaning is used in liquid bubble breaking crack generated by shock waves to wash and scour workpieces inside and outside surface of the effect
Q:What problems should we pay attention to when using ultrasonic cleaners?
When the ultrasonic cleaning machine is not in use, it is strictly prohibited to turn on the machine. There is no cleaning liquid and no power on
Q:What about the damage to the ultrasonic cleaner's transducer?
The insulation strength of the transducer is measured by a shake meter. The insulation strength is below 200M. The transducer has not been used. The transducer must be replaced
Q:How to choose cleaning fluid for ultrasonic cleaner?
Selecting the proper cleaning solution is critical for effective cleaning of the workpiece and eliminating unnecessary reactions. Sure, the letter can provide you with the best cleaning solution.
Q:What about the damage of the ultrasonic cleaner and the isolating transformer?
Inductance, transformer damage, in most cases, intuitive to see traces of burned, replace the new device
Q:What about the damage to the power tube of the ultrasonic cleaner?
When the power tube is connected on the main board, the resistance value of both sides of the power tube can be measured by a multimeter. Under normal conditions, it should be around 22 ohms
Q:Why does the ultrasonic cleaner need to keep the cleaning liquid within the allowable height of the liquid level indicator?
Improper liquid level will change the cleaning environment, reduce cleaning efficiency, and damage equipment
Q:How can the pressure pipe of ultrasonic cleaner be damaged?
According to the diode characteristic, the positive conduction, the reverse ended. Measured with a multimeter diode, the forward resistance is about 70, and the reverse is infinite
Q:When does the ultrasonic cleaner change the cleaning solution?
When cleaning, you can see the obvious cleaning liquid, it should be replaced

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range