1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

Ref Price:
Loading Port:
Guangzhou
Payment Terms:
TT OR LC
Min Order Qty:
30 unit
Supply Capability:
300000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

ModelRT-1KSRT-1KLRT-2KSRT-2KLRT-3KSRT-3KL
Rated power1KVA2KVA3KVA
DisplayLED or LCD, depends on user's choice
INPUT
Voltage110V:80~138VAC/220V:115~300VAC
Frequency110V:46~54Hz or 56~64Hz/220V:40~60Hz/Adjustable by software
OUTPUT
Voltage110V:110±2%VAC/220V:220±2%VAC
Frequency110V:46~64Hz/220V:46~54Hz/Same as AC(AC mode)
110V: 50 or 60±0.2Hz/220V:50±0.2Hz(Batt. mode)
Wave formSine wave
BATTERY
QTY. & capacity of battery12V/7.5AH*3pcs—————2V/7.5AH*8pcs—————12V/7.5AH*8pcs—————
Nominal DC input voltage—————36VDC—————96VDC—————96VDC
Transfer time0 ms
Overload capability110%~150% for 30% seconds then transfer to bypass output, 150% above for 300 milliseconds.
ENVIRONMENT
Environment of performanceTemperature 0℃~40℃, Humidity 20%~90%
PHYSITAL
(kg) / Net weight (kg)110V:19   220V:16.3110V:11.8 220V:9.138.1kg(10.3kg for US+27.8kg for battery pack)110V:14.2 220V:11.539kg(11.2kg for US+27.8kg for battery pack)110V:15 220V:12.3
(mm) / Unit dimention (mm)441*445*88441*445*88(*2 sets, there into 1 set for battery pack)441*445*88441*445*88(*2 sets, there into 1 set for battery pack)441*445*88
MANAGEMENT
Interface110V:USB+RS232 220V:RJ45/11+RS232, Intelling slot selectable.

 

 

1. Wide range of input voltage

The UPS can offer normal and stable service voltage under its input voltage range. When the input voltage is out of its range the machine will switch to battery mode automatically to keep the output power in order to protect the equipment, such as computers, ensure they will not be damaged by the over high or over low voltage, users can continue the operation of equipment for a while or save the data on computers while the power network is abnormal.

 

2. Wide range of AVR(Automatic voltage regulation)

In the product’s input voltage range and under 3 steps of intelligent AVR function, it can provide a stable output voltage.

 

3. Automatic self detection when UPS on(LED).

Before the UPS on, red, yellow, blue LED will light up two times by cycle turns, after self detection UPS switch to AC mode/battery mode or working mode. 

 

4. Silence function

In the "battery mode", shortly press the switch to turn off the buzzer. But the battery is about to run out or the load is too heavy, the buzzer sound cannot be muted.

 

5. Overload protection

In the battery mode, output voltage turn down correspondingly when it is overload, after the capacity of load is lower than the rated power then output voltage will back to rated value, it ensures the UPS will not shut down by abrupt overload which caused by surging current during the computer is working and other equipment is added.

 

6. Short circuit protection

When the mis-operation caused the load short circuit or computer failure (such as power tube breakdown of switch) cause short circuit, the UPS will shutdown automatically for protection.

 

7. The low current switch

This UPS adopts low current switch to extend the service life which is longer than conventional battery and high current switch in AC current path.

 

8. Automatic charging

There are two charging mode, charging time is faster than ordinary charging mode, higher efficiency, and greatly prolonging the service life of the battery.

 

9. With a bypass output

Independent bypass output socket for external printers or scanners of computer peripherals, with surge protection of the load.

 

1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

1KVA Rack / Tower Puresine Wave Online Extensible G-sensor LCD UPS 1

FAQ

1.    Where can I buy your products?

You could find our products from dealers or contact our sales team directly. We will provide you with detailed services.

2.    How to contact us?

Contact details can be found from website www.okorder.com to contact us. We look forward to providing you with professional services.

3.    What is the application field of your products?

Our current GW1500~4600-SS series and GW3000~4600-DS, with the flexible expansion ability and allocation capability, can be used in the small photovoltaic (PV) grid power generation systems of family units as well as the commercial photovoltaic system such as BIPV, BAPV and etc.

4.    What kinds of modules do your inventers support?

Our inventers support most of mainstream components and modules in the market. Should you require more details, please do not hesitate to contact our technical personnel.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the PV inverter starting voltage
Photovoltaic inverter, also known as power regulator, according to the inverter in the use of photovoltaic power generation system can be divided into two kinds of independent power supply and grid. According to the waveform modulation method can be divided into square wave inverter, stepped wave inverter, sine wave inverter and modular three-phase inverter. For the inverter for the grid system, depending on whether the transformer can be divided into transformer-type inverter and transformer-free inverter.
Q:Photovoltaic grid-connected inverter without DC emc how will happen
can convert light energy into electricity, so that the current flow from one side to the other, the general can be issued equivalent to 10 to 20% of the received light energy. In general, the stronger the light, the more electricity is generated. Its working principle is based on the semiconductor PN junction of the photovoltaic effect. The so-called photodynamic effect is when the object by the light, the object within the charge distribution of the state of the electromotive force and current generated an effect.
Q:PV grid-connected inverter can directly load it?
TL5001 operating voltage range of 3.6 ~ 40V, its internal with an error amplifier, a regulator, oscillator, a dead zone control PWM generator, low voltage protection circuit and short circuit protection circuit
Q:Solar grid inverter does not merge into the grid, direct access to the load to the load power supply?
The solar grid-connected inverter is not connected to the grid and can not be directly connected to the load to supply power to the load because there is no voltage.
Q:What is the difference between a PV inverter and a solar inverter?
Instability, the wind speed and the equipment itself will directly affect the generator rotation, so the voltage and current fluctuations, frequency instability, in short, is the power quality is poor) Therefore, through the inverter after the first rectification inverter to improve the quality of power
Q:The function of photovoltaic grid - connected inverter
By dc / dc conversion to increase or decrease the input voltage, adjust its output to achieve maximum efficiency.
Q:What is the difference between low voltage grid connection and medium voltage grid connection?
When the power grid failure or disturbance caused by the power supply and network voltage drop, in the voltage drop range, the power group can be uninterrupted through the inverter and network operation.
Q:What is the difference between a PV grid-connected inverter and an off-grid inverter?
Grid-connected inverter will be directly sent to the power grid, so to track the frequency of the grid, phase, the equivalent of a current source. Of course, there are some inverters called low-voltage crossing ability, you can do PQ adjustment
Q:In a photovoltaic grid-connected project, the role of the inverter is to convert the voltage into AC 220V or 380V for the grid, since the transformer will raise the voltage again
Spontaneous use is a way of grid, that is issued to the electricity, mainly their own family or internal use, the excess part of the power to the grid
Q:What is the difference between a grid-connected inverter and an off-grid inverter? What are the advantages of a hybrid inverter?
Grid-connected inverter will be directly sent to the power grid, so to track the frequency of the grid, phase, the equivalent of a current source. Of course, there are some inverters that have a low-pressure through the ability to do PQ adjustment.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range