1700CSilicon Carbide SiC Bond Si3N4 Tube Supplied by CNBM

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
25 m.t.
Supply Capability:
2000 m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Packaging & Delivery

Packaging Details:1.The finished silicon refractory product are packed in wooden cases 
2.According to your requirements
Delivery Detail:About 7-20days after receiving the deposit

1700C silicon carbide SiC bond Si3N4 tube 1700C silicon carbide SiC bond Si3N4 tube

Silicon Nitride (Si3N4) bonded silicon carbide (SiC) material is a new type of advanced refractory materials. Compared with silicon carbide product, the product has characteristics of small thermal expansion, high thermal conductivity, not easy to have thermal stress, good thermal shock resistance, corrosion resistance, extreme cold or heat, oxidation, high temperature creep resistant ability and easily made into products with high dimensional accuracy requirements in line. Silicon nitride combined silicon carbide products have very high strength for normal atmospheric temperature, and it remains almost the same time with the strength and hardness at high temperature 1200-1400C. with the difference of using atmosphere, the maximum safe operating temperature could reach 1650-1750C.

 

Project

Index

Apparent porosity

≤16%

Bulk density

≥2.65g/cm3

Cold compression strength 

≥160Mpa

Modulus rapture at room temperature  1400C

≥45Mpa

Modulus rapture at elevated temperature 1400C

≥50Mpa

Coefficient of thermal liner expansion 1100Cx10‾6/C

4.18

Thermal conductvity  1100C w·m‾1·k‾1

≥17

Refractoriness

1800C

0.2Mpa loading softening point

1600C

Max working temperature

1550C

 

Composition %

SiC

≥71

Si3N4

≥23

Fe2O3

≤1.0

Si

≤0.4


1700CSilicon Carbide SiC Bond Si3N4 Tube Supplied by CNBM


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What kind of materials are needed to make refractory bricks?
The components of the raw materials of refractory bricks. There are many types of raw materials, mainly divided into six categories: Earth, stone, sand, ore, powder and others. No.1, earth: bauxite, kaolin, clay, kieselguhr. No.2 Two: stone: fluorite, kyanite, andalusite, forsterite, vermiculite, mullite, pyrophyllite, chlorite and dolomite, sillimanite and spinel, silica. No.3: sand: ceramic sand, zircon sand, quartz sand, magnesia. No.4, ore: chrome ore. No.5, powder: Metal powder, silicon powder, metal powder. No.6, others: Asphalt and graphite, phenolic resin, perlite, cenosphere, sialon corundum silicon sulfate, silicon carbide, water glass, silica sol, boron carbide, calcium aluminate cement, nitride materials, shale ceramsite, alumina, aluminum sol, zirconia.
Q:which kind of fire bulkhead is better?
I think fire bulkhead is good, fire bulkhead also known as non-combustible fire retardance board, and it's made by various incombustible material after the scientific pressing, and has good flame resisting properties, it's non-combustible time can reach over 3 hours, high mechanical strength,it has characteristics of non-explosive, water and oil resistance, good chemical corrosion resistance and non-toxic.
Q:How long is the fire endurance of Grade A fire resisting shutter
The fire endurance of Grade A fire resisting shutter is not lower than 1.20h. Use fire resisting shutter as fire compartment separation in places where it is difficult to set firewall. When fire resisting shutter whose unexposed surface temperature rise is used as judging condition of fire endurance is used, its fire endurance should not be lower than 3h. When fire resisting shutter whose unexposed surface temperature rise is used as judging condition of fire endurance is not used, individual protection of  closed automatic water spray system shoule be set at two sides of the shutters and duration of water spray system should not be less than 3.0h.
Q:What's the requirements of fire-fighting criteria of heat insulating material?
It shouldn't be under than B2 level. Roofing insulation fire rating requirements: the ministry of public security, housing and urban-rural development department issued about printing and distributing the civil building external thermal insulation system and the interim provisions on the exterior wall decorative fireproof prescribed in the notice: roof grassroots adopted duration of fire resistance is the non-combustible component that shouldn't less than 1.00 h's. Its roof insulation materials should not be below B2; Otherwise, the combustion performance of insulating material should not be below the B1 level. The junction of the roof and wall, the insulation layer around the opening part of roof should use the grade A thermal insulation material to set level fire-fighting belt that width is not less than 500 mm.
Q:Who knows the roofing fireproofing and waterproof material?
Colorful glass fiber asphalt shingles the roofing through special materials treatment just like wearing a waterproof, fireproof coat, water rolling down from the roof is similar to the effect of lotus leaf drops, the wall will be always in the dry state, having excellent waterproof, mould proof, efflorescence and weathering. It can prevent the growth of moss and keep the surface clean. And let your roof does not change color for a long time. Colorful fiberglass asphalt shingles materials are widely used in: All types of buildings roofing waterproofing, leak, fire, pollution, wind, and mould proof and moisture-proof of libraries and archives. The color retention of ancient architecture and protection of human cultural relics. Through the number of ten million square meters of engineering applications and two decades of practical test, it welcomed by users.
Q:How to detect the acid resistance of refractory? Is there any standard? Thank you
There is a standard. However, the range what you said is a little big, it's difficult for me to say. But though the scope is a bit big, it should be: You can check the industry standard network, to see whether you can check it.
Q:What is the fireproofing requirements of external wall thermal insulation materials?
in the 2011 and 2012 revised version of "Fireproof  Specification of Building Design" in China, the external insulating layer of above 50 meters (approximately 16 layers) of the housing must use the level A material. The latest draft for approval is not so strict, above 100 meters (about 33 layers) only use level A material. The manuscript of "Building Regulations" is also regulated building's external wall thermal insulation materials in the crowded places should be level A. Except the residential buildings and the buildings in the crowded places, the height of other buildings is greater than 50 meters, combustion performance of insulation materials should be level A; the height buildings is greater than 24 meters but not more than 50 meters, combustion performance of insulation materials should not be lower than level B1. "Building Regulations" manuscript should relax the rules on the aspect of protective coating in level B1 and B2 insulation material. The outer of level B1 and B2 level insulation material must use incombustible material as protective coating, its thickness is changed from the original 10 cm to 5 cm. Given certain conditions, I feel you can use TDD exterior wall thermal insulation decoration integrated rock wool board for construction, which is level A fireproofing with a short construction period and good thermal insulation properties. I hope I can help you!
Q:Can anyone tell me what material the first rate fire resistant door is?
Class A fire door materials are mainly steel, wood, steel and wood,and other materials. If there is filling material in a Class A fire door, it is generally the perlite. According to the actual situation in China, the fire doors and windows are divided into class A, class B, class C, whose minimum fire endurances are stipulated, namely class A 1.50h, class B 1.00h, Class C 0.50h. There are fireproof wooden doors and fireproof steel doors. whose main purpose is to achieve fire endurance time. But door closers are required to be installed.
Q:What are the specifications of fire resistant bag?
Mesh number, namely hole number, refers to the hold number in each square inch. 5o mesh refers to 50 holes in each square inch and 500 mesh 500 holes. The larger the mesh number is, the more the holes are. The larger the mesh number is, the smaller the hole aperture is. Generally speaking, mesh number× aperture (microns) = 15000. For example, the aperture of a sieve of 400 mesh is about 38 microns; the aperture of a sieve of 500 mesh is about 30 microns.
Q:The structure of refractory material

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range