1700CSilicon Carbide SiC Bond Si3N4 Tube Supplied by CNBM

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
25 m.t.
Supply Capability:
2000 m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Packaging & Delivery

Packaging Details:1.The finished silicon refractory product are packed in wooden cases 
2.According to your requirements
Delivery Detail:About 7-20days after receiving the deposit

1700C silicon carbide SiC bond Si3N4 tube 1700C silicon carbide SiC bond Si3N4 tube

Silicon Nitride (Si3N4) bonded silicon carbide (SiC) material is a new type of advanced refractory materials. Compared with silicon carbide product, the product has characteristics of small thermal expansion, high thermal conductivity, not easy to have thermal stress, good thermal shock resistance, corrosion resistance, extreme cold or heat, oxidation, high temperature creep resistant ability and easily made into products with high dimensional accuracy requirements in line. Silicon nitride combined silicon carbide products have very high strength for normal atmospheric temperature, and it remains almost the same time with the strength and hardness at high temperature 1200-1400C. with the difference of using atmosphere, the maximum safe operating temperature could reach 1650-1750C.

 

Project

Index

Apparent porosity

≤16%

Bulk density

≥2.65g/cm3

Cold compression strength 

≥160Mpa

Modulus rapture at room temperature  1400C

≥45Mpa

Modulus rapture at elevated temperature 1400C

≥50Mpa

Coefficient of thermal liner expansion 1100Cx10‾6/C

4.18

Thermal conductvity  1100C w·m‾1·k‾1

≥17

Refractoriness

1800C

0.2Mpa loading softening point

1600C

Max working temperature

1550C

 

Composition %

SiC

≥71

Si3N4

≥23

Fe2O3

≤1.0

Si

≤0.4


1700CSilicon Carbide SiC Bond Si3N4 Tube Supplied by CNBM


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How long is the fire endurance of fire resistant rolling shutter door?
According to fire endurance, fire doors can be divided into Class A, Class B and Class C fire doors, whose fire resistance should be no less than 1.20h, 0.90h and 0.60h respectively. You can use fire resisting shutters to seperate fire compartments in places where it is difficult to set firewalls. When using the fire resisting shutter with unexposed surface temperature rise as fire endurance conditions, its fire endurance should be no less than 3h. But when using the fire resisting shutter without unexposed surface temperature rise as fire endurance conditions, you should set independent protection of closed automatic water spray system at two sides of the shutter, and the duration of water spraying should be no less than 3.0h. I hope it's useful.
Q:How to detect the acid resistance of refractory? Is there any standard? Thank you
Setting the acid resistancere of fractory products is simple; R22, two measurement methods are both bricking refractory products, using the mass fraction of the original dry to indicate. It is generally select vitriol as the medium of erosion, such as the international standard determination of the resistance to sulfate of dense shaped refractory products "(ISO8890) and PRE /, grinding fine particles to 0.63 ~ 0.80 mm, and then measure its quality loss, put it in the vitriol with mass fraction of 70%, finally boil 6 h.
Q:what are the types of piping insulation material fire rating?
There are two grades: 1, the organic material: Grade B Grade B1 hard combustion (fire retardant) 2, inorganic materials: class A no burning it is divided into three levels, attributed to the types of materials!
Q:What needs to be paid attention to in the construction of high- temperature refractory mortar?
As far as I'm concerned, in the construction of high-temperature refractory mortar, these matters should be noted: 1. During the use of high-temperature daub masonry stove, the minimum mortar joint should be 0.5mm and general mortar joint should be 3-5mm, which can solve the processing and fine grinding of refractory brick on the brick grinder. Besides, it is conducive to the health of workers, and can reduce the masonry effort, ensure the quality and speed up the construction progress. 2. When making urgent repair on the stove, if the joint is much too large, 2-3mm refractory pieces can be appropriately added into the high- temperature refractory mortar, and stirred to fill the joint so as to shorten the repair time and ensure normal production. 3. High- temperature refractory mortar can be painted inside various furnace body, and it should be guaranteed that the surface of the furnace body has no dust or debris before painting.
Q:Which brand of AAA refractory is good?
The most famous is fire dragon. The Morgan and Lu Yang are all very good at making common thermal insulation material. The price is not very expensive, and the quality is comparatively good. The refractories are capable of good thermal shock resistance ability and chemical errosion resistance ability It is a non-metal material with a low heat conductivity coefficient and expansion coefficient. It requires high temperature in nature. The production base of silicious thermal insulation board is difficult to transport raw material. The silicious thermal insulation board is a high temperature thermal insulation material with the raw material of non-porous refractory aggregate and porous refractory aggregate, organic fiber and inorganic fiber.
Q:What are the requirements of the performances of brasque refractory?
Physical properties of refractory include structural properties, thermal properties, mechanical properties, usability and operation property. The selection of the brasque refractory must have the following characteristics: 1. properties of not distortion and not melting at sufficient temperatures 2. have the necessary structural strength at high temperatures and does not soften and deform 3. must keep stable volume at high temperatures and will notcrack caused by expansion and contraction 4. will not rapture and flake when temperature is drasticly changed or heated unevenly 5. resistant to chemical erosion of metallic solution, slag and furnace gas, etc.
Q:How should fireproof building materials be ranked?
5. Civil building 5.1. Fire resistance rating, number of layers and floorage of civil buildings 5.1.1. Fire resistance rating of civil buildings should be classified into four levels of first, second, third and fourth. Unless otherwise specified in the code, the combustion performance and fire endurance of building components with different fire resistance rating should be no less than that of the regulations in Table 5.1.1. Table 5.1.1: Combustion Performance and Fire Endurance (h) of Building Components (Figure) Note: 1. Unless otherwise specified in the Code, the fire resistance rating of the building with wooden pillars as load-bearing and incombustible material as the building wall should be the fourth level; 2. For the suspended ceiling of the building with the second level of fire resistance rating, if it uses non-combustible component, it won't be limited in its fire endurance; 3. For buildings with the second level of fire resistance rating, if it is really difficult for the partition wall of rooms with the area of no less than 100m2 to implement the regulations of the Table, the partition wall can adopt the non-combustible component with fire endurance of no less than 0.3h; 4. For buildings with the first or second level of fire resistance rating, if it is really difficult for the partition wall of both sides of the evacuation walk to implement the regulations of the Table, the partition wall can adopt the non-combustible component with fire endurance of no less than 0.75h. 5. Fire endurance and combustion performance of the residential building component can be implemented in accordance with the provisions of current national standard GB 50368 "Residential Building Code".
Q:How long is the fire-resistant time of fireproof wooden door?
Wooden thermal insulation fireproof door using flame-retardant timber or flame-retardant timber products to make door frames, skeletons of door leaf, door panels. If the door leaf need to be filled with materials, the filling materials should be fireproof thermal insulation materials which is non-toxic and harmless to human body, and matched fireproof door composed of fireproof hardware. Use doors without age limits.
Q:what is the requirements of roofing insulation materials fire rating?
The fireproofing requirements of architectural design are regulated by architectural design fire safety rules, roofing insulation material only has the requirements of materials combustion performance, namely non-combustible material. No fire rating requirements.
Q:What's the fire endurance of A grade fireproof glass curtain wall?
The following is fire endurance of A class fireproof glass curtain wall. Fire endurance of the fire window: A class fire window: no less than 1.2h; B class fire window: no less than 0.9h; C class fire window: no less than 0.6h. Technical requirements: 1. Materials and fittings: (1) Window frame should adopt the steel frame or wood frame with certain strength so as to guarantee the integrality and stability of the fitting; (2) Steel frame and mound layer can choose the galvanized steel sheet or stainless steel sheet. Its selection standard is in line with provisions of Article 5.1 in GB12955 "General Technical Requirements on Steel Fire Doors"; (3) Selection standard of wood frame and mound layer should be consistent with the provisions of Article 5.1.1 in GB14101 "General Technical Requirements on Wood Fire Doors"; (4) Filler material inside the steel frame and wood frame should be incombustible material; (5) Fireproof glass can choose the qualified product with no influence on the fire resistance test of the fire window, and its light transmittance should be no less than 75% of that of the ordinary sheet glass with the same layers; (6) Sealing material between the frame and the fireproof glass should use flame retardant material which can play the role of fire prevention and smoke insulation in case of fire. Hope it's helpful for you.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range