12/20kv three-core XLPE insulated PVC sheathed power cable(YJV,YJLV)

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
10000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Nominal
Cross-
sectional
Area of
Cable
Nomin-
allnsul-
ation Th-
lckness
She-
ath Th-
lckness
Approx
Quter Dl-
ameter Ofc-
able
Approx
Weight
of
Cable
D.C
Realstance
of Cable
at 20°C
A.C Reals-
tance at
Operating
Temperature
CuALCuALCuALCuAL
mm²mmmmmmmmkg/kmkg/kmΩ/KmΩ/KmΩ/KmΩ/Km
25--------------------
355.52.755.055.0323325700.5240.8680.66841.1130
505.52.858.058.0381028620.3870.6410.49370.8220
705.52.962.062.0471033840.2680.4430.34210.5682
955.53.066.066.0569338940.1930.3200.24660.4106
1205.53.169.069.0654542720.1530.2530.19580.3248
1505.53.272.072.0758047390.1240.2060.15900.2646
1855.53.376.076.0883653310.09910.1640.12750.2110
2405.53.581.081.01083062840.07540.1250.09770.1612
3005.53.686.086.01279571130.06010.1000.07870.1295
4005.53.791.091.01476079420.04070.07780.06270.1017
5005.53.896.096.01672587710.03660.06050.05030.0798



Oparat-
ing Cap-
acity
Cable
induction
Reactive
impeda-
nce of
Cable
Positive
Negative
Sequence
impedance
Zero Sequence
impedance
Short-circuit
Current
CuALCuALConductorScreen
Cu
tape
Cu
Wire
Cu
tape
Cu
Wire
CuALCu
tape
Cu
Wire
uF/KmMH/KmΩ/KmΩ/KmΩ/KmΩ/KmΩ/KmΩ/KmΩ/KmKAKAKAKA
--------------------------
0.15020.40640.40640.12760.68051.12033.25751.95252.39675.153.372.958--
0.16610.38450.38450.12070.50820.83083.08271.77962.10767.314.792.958--
0.18680.36200.36200.11370.36050.57952.94091.63291.858710.26.682.958--
0.20600.34540.34540.10850.26940.42472.46651.06501.228613.89.022.958--
0.22280.33920.33920.10650.22290.34182.41561.01511.143917.411.42.958--
0.24180.32170.32170.10100.18840.28322.37870.97911.084521.714.22.958--
0.26560.31450.31450.09880.16130.23302.35820.72110.804326.717.53.031--
0.29160.30300.30300.09510.13630.18722.31730.69210.755434.622.63.031--
0.31750.29350.29350.09220.12120.15902.30800.67290.723643.126.23.031--
0.35510.28220.28220.08860.10850.13492.28210.65970.698657.437.63.031--
0.38800.27420.27420.08610.09970.11742.26960.64910.678671.747.03.031--


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:power cable on hifonics zeus?
i would hook it up to the power cable from ur stero that whay the amp will only come on when the radio comes on. that way u wont drain ur battery, thats if ur talking about the remote cable
Q:Why do Craftsman and Porter Cable share power tools?
Most everything is made by one manufacturer different companies that order enough of anything can have there own branding on them the brands you have mentioned are at the lower end of the spectrum as for quality you will probably discover that the cheapest lithium ion cordless drill is just as good as the most expensive one on the market
Q:high effency double shielded transmission power cable?
What is your question? Does such a cable exist? Probably but you'll have to be more specific. High efficiency = low loss or low resistance per foot? Double shielded = is the shielding (in dB) critical? Transmission = What frequency, 60 Hz, 1 MHz, 100 MHz, ? Power = Watts, KW, MW Is weight or cost important?
Q:My dell power cable isn't working.?
It could be your cable or power supply unit went bad. Or, your power socket on the main board went south. The good thing about laptops is that the power supply unit is external and easy to swap out.
Q:Do data cables for dvd drives/hard drives ome with the drive or psu or motherboard?
IDE or SATA data cables come with the motherboard.
Q:What is the difference between a pre-branch cable and a punched clip?
. soil buried pipe, including weak and fire, should be thick-walled galvanized steel pipe, that is, SC series of steel pipe, the best size is not less than SC. weak professional, decorative professional now basically use thin-walled galvanized steel pipe, that is JDG series steel pipe
Q:TVRS Glasgow question ?
All TV repair people have all the power cables they could need. BUT... if they think that your fault could simply be a fault in your cable, then they may take it with them, though they would be more likely to try swapping it on your premises before removing the set.
Q:Can I use a LCD monitor power cable on a CRT monitor?
Yes u cn use it
Q:can i hook up small constant power cables to ignition constant power cable?
confident, you're able to do this. make beneficial each and every capability twine has its own fuse close to the battery. Addressing the different solutions: this won't drain the battery any quicker than working a single twine to a distribution block; and there isn't any might desire to characteristic a 2d battery except you intend to play the gadget for long classes without the engine working.
Q:Need a laptop power cable with Australian plug. Help?
Just get a small plug adapter in Australia. That will be cheaper than buying a whole new power cable.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range