Product Description:

Detailed Product Description

 

      100kva 1006-6TAG Water Cooled Genset Diesel Generator, Perkins Industrial Diesel Engine

 

 

100kva 125kva 150kva 200kva Perkins Power Genset Diesel Generator

 

1. UK Perkins diesel engine  1006-6TAG,1106A-E66TAG3

2. 220V/380V,240V/415V, 3phase ,50Hz, 1500RPM


3.  24V charge alternator ,AVR self-regulated, voltage regulation rate: ≤±1%

4.Water Cooled


 


Specifications:

 

Genset Model

Prime Power

Standby Power

Engine

Fuel Consumption

Cylinder No.

Displacement

Bore X Stroke

KW

KVA

KW

KVA

(g/kwh)

 (L )

(mm)

GNRP10

7

9

8

10

403D-11

≤252

3

1.131

77*81

GNRP15

10

13

12

15

403D-15

≤264

3

1.496

84*94

GNRP23

16

20

18

23

404D-22

≤243

4

2.216

84*100

GNRP33

24

30

26

33

1103A-33G

≤210

3

3.3

105*127

GNRP50

36

45

40

50

1103A-33TG1

≤212

3

3.3

105*127

GNRP65

48

60

52

65

1103A-33TG2

≤211

3

3.3

105*127

GNRP73

52

65

58

73

1104A-44TG1

≤207

4

4.4

105*127

GNRP88

64

80

70

88

1104A-44TG2

≤213

4

4.4

105*127

GNRP103

75

94

82

103

1006TG1A

≤210

6

5.99

100*127

GNRP150

110

138

120

150

1006TAG

≤205

6

5.99

100*127

GNRP165

120

150

132

165

1006TAG2

≤205

6

5.99

100*127

GNRP225E

165

206

180

225

1306C-E87TAG3

≤220

6

8.7

117*136

GNRP250E

180

225

200

250

1306C-E87TAG4

≤219

6

8.7

117*136

GNRP259E

188

235

207

259

1306C-E87TAG5

≤221

6

8.7

117*136

GNRP275E

200

250

220

275

1306C-E87TAG6

≤223

6

8.7

117*136

GNRP344E

250

313

275

344

2206C-E13TAG2

≤201

6

14.6

137*165

GNRP388E

280

350

310

388

2206C-E13TAG2

≤198

6

14.6

137*165

GNRP450E

320

400

360

450

2206C-E13TAG3

≤201

6

14.6

137*165

GNRP500E

360

450

400

500

2506C-E15TAG1

≤216

6

15

137*171

GNRP550E

400

500

440

550

2506C-E15TAG2

≤211

6

15

137*171

GNRP625E

450

563

500

625

2806A-E18TAG1A

≤196

6

18.13

145*183

GNRP700E

508

635

560

700

2806A-E18TAG2

≤203

6

18.13

145*183

GNRP800

580

725

640

800

4006-23TAG2A

≤199

6

22.921

160*190

GNRP900

640

800

720

900

4006-23TAG3A

≤200

6

22.921

160*190

GNRP1000

720

900

800

1000

4008-TAG1A

≤206

8

30.561

160*190

GNRP1125

818

1022

900

1125

4008-TAG2A

≤208

8

30.561

160*190

GNRP1375

1000

1250

1100

1375

4012-46TWG2A

≤212

12

45.482

160*190

  

 

  Genset Features:

 

1. Genuine UK Perkins industrial diesel engine

2. Radiator 40°C max, fans are driven by belt, with safety guard

3. Genuine stamford. Leroy somer, marathonm, engga alternator

4. Choice of manual/auto and AMF control panels and protection systems

5. Digital auto-start panel

6. Anti Vibration Suspension Absorber

7. Dry type air filter, fuel filter, oil filter

8. 10-hour operation base tank

9.Mould case circuit breaker

10. 24V DC start motor and storage battery

11. 24V charge alternator

12. 24V batteries, rack and cable

13. Rippl;e flex echaust pipe, exhaust siphon, flange, and muffler

14. Comply with ISO and CE standards

15. All generator sets are gone through rigorous testing before beging released to the market place, including 50% load, 75% load, 100% load and all protection function(over speed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

 

 

Engine Features:

 

1. Genuine UK Perkins industrial diesel engine

2. Multi-cylinder in-line or veer engine, 4-stroke, direct injection

3. Naturally aspirated, turbocharged, water cooled or turbocharged with air intercooler

4. Machinery or electronic governing

5. Fuel injection pump

6. Electric motor starting system

7. Forged steel crankshaft, cast iron cylinder and replaceable wet type cylinder liner

8. Low discharge, and low fuel consumption

9. Installed conveniently and maintain easily

 

 

Alternator Features:

 

1. World famous brand AC alternator: Leroy Somer, Stamford, Marathon, ENGGA

2. Brushless, 4 poles, rotation magnet

3. IP21-23(NEMA1) enclose is standard for all industrial alternators

4. H class insulation system

5. AVR self-regulated, voltage regulation rate: ≤±1%

6. Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts

7. Wide range of flange adaptors and single bearing disc coupling

8. Radio interference restraining accords with the stipulation of VDE0875-N and ISO8528

9. Moisture proof, sand-proof, dustproof, salt-proof and vibration-proof

 

 

Digital Control panel

Controller Brand: Smartgen, Deepsea,ComAp

Control Panel: English interface,LED screen and touch buttons.

 

 

Main Functions:

 

1- Display loading power, voltage, currenct, frequency, speed, temperature, oil pressure, running time etc.

2- Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc.

3- Over load protection, over/under frequency protection, over/under/imbalance voltage protection, and low oil shutdown

 

 

Soundproof/Silent Box:

 

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<80DBA / 7m<70DBA

 

 

Optional:

 

1. Trailer type

2. Soundproof / water proof

3. ATS (automatic transfer switch)

4. Parallel system

5. Remote system

 

 

PMC System:

 

1. Standard 23 pitch windings avoid excessive neutral current

2. Permanent magnet generator system provides constant excitation under all condition

3. Optional accessories available for easy paralleling with mains or other generators

4. AVR auto voltage regulation, auto exciter, auto adjustment

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Can ordinary motors be controlled by transducers?
First introduce the frequency conversion motor: look from the appearance, the most obvious is characterized by frequency conversion motor have a single cooling fan, and a cooling fan has a special connection box. The cooling fan needs to be connected to the power supply alone, so that no matter how often the motor works, it will not affect the heat dissipation of the motor. Second, the frequency conversion machine manufactured by the regular manufacturer will be adjusted internally, and it will also strengthen insulation. If there is a problem with ordinary asynchronous motor, it should be analyzed according to the situation. For example, the motor is working in low-frequency areas, and the motor may be damaged by heat dissipation. If the motor is working in the medium-high frequency area, the ordinary motor can also use the frequency converter. Also, it is the insulation problem of ordinary electric motor, the proposal is to install output reactor. Of course, it's not necessary.
Q:What is the difference between the two class motors and the four-stage motors?
The number of the most numerous is the relation between the electric frequency and the mechanical speed, n = 120f/P, n is the mechanical speed, f is the electric frequency, and P is the extreme number. But it doesn't have anything to do with "good." A lot of people say very many, large torque, in fact the two are no significant relationship, the poles of three-phase motor torque T = kBr * Bsk is constant, Br is the rotor magnetic field intensity, Bs is produced by the armature magnetic field intensity, * to cross. When you're in the 4 pole, you feel like you have two torque T, and the torque seems to be twice,
Q:Direct drive motor control mode
So there is no such thing as "the frame type is the control mode of the permanent magnet synchronous motor, the no-frame type is the control mode of dc brushless motor". Perhaps your motor coincided with a particular type of "frame with permanent magnet synchronous motor control mode" or the different type of brushless dc motor control way ". In fact, permanent magnet synchronous motor control method and two kinds of brushless dc motor control method in most cases is one thing, there is not much difference.
Q:Can I use the servo motor?
Can't use what you have said that four thread is U V W the servo motor controller, servo motor by the pulse signal, the line 9 is the servo motor, photoelectric encoder is to control the servo motor torque, speed and Angle.
Q:What's the difference between a TEFC motor and a regular motor
The TEFC motor is cooled by the air of the motor casing, and the air is provided by the fan mounted on the motor shaft. The common motor USES the fan ventilation cooling on the shaft of the machine, forcing the air to flow through the open end of the motor, from both sides.
Q:The difference between B34 and B35 motors
B34, the difference between B35 is the size of the flange. B34 is a code for the installation method. Small flange mounting, bottom foot. And B35 is the FF flange installation, with the bottom foot, and B5 is the FF flange installation without the bottom foot.
Q:The difference between servo motor and general motor?
The problem of motor insulation strength is the small and medium frequency converter, many of which are controlled by PWM. He is about several thousand to more than 10 KHZ carrier frequency, which makes the motor stator winding to withstand high voltage build-up rate, equivalent to impose great impulse voltage gradient on motor, the motor of the turn-to-turn insulation withstand ordeal. In addition, the rectangular produced by PWM inverter chopper superposition of impulse voltage on the motor running voltage, would pose a threat to ground insulation of motor, the ground under the repeated impact of high voltage insulation can accelerate ageing. 3, harmonic electromagnetic noise and vibration Ordinary asynchronous motor by inverter power supply, can make the electromagnetic, mechanical, ventilation and other factors caused by the vibration and noise becomes more complicated. The internal harmonic interference of the different time harmonic and the electromagnetism of electromagnetism in the frequency conversion power supply, form various electromagnetic excitation forces. When the frequency of the electromagnetic wave is consistent or close to the natural vibration frequency of the motor body, the resonant phenomenon will be generated to increase the noise. Because the frequency of the motor is wide, the speed varies widely, and the frequency of all kinds of electromagnetic waves is difficult to avoid the natural vibration frequency of each component of the motor.
Q:What is the difference between a general motor and a converter machine?
It is true that the current trend of motor equipment is adjustable, and most motors can be controlled by frequency conversion
Q:The advantage of the pole motor relative to the ordinary motor
For users, the only benefit of a pole machine is the cheap. The pole type motor is the simplest form of a one-way ac motor. The advantage of a pole machine is that it is simple in structure, without the addition of a starting winding and starting capacitor. The drawback is that it's inefficient and it's bad. If the environment is harsh and closed, it should be considered that the electromagnetic load is low because it is difficult to heat the heat. Or, you could think of a slightly more powerful machine.
Q:What is an electric motor
Electric motors are powered by electric induction.I hope my answer will help you

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range