0.6/1kVCopper Core Plastic Insulation Pre-fabricated Branch Cable

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
10000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Application

This products is apply to the power distribution system of residence, office building, hotel, hospital, shopping mall, factory and so on.


2、Type and Specification

Voltage Class

0.6/1 kV

Type

YFD-YJV/FZYJV、YFD-YJY/FZYJY、YFD-WDZ-YJY/WDZ-FZYJY、YFD-WDZN-YJY/WDZN-FZYJY、YFD-NH-YJY/NH-FZYJY etc.

Size (mm2)

1 core:main cable 10~500;branch cable 6~240;
 2、3、4、5 cores, 3+1、3+2、4+1  cores:main cable 10~240;branch cable  6~120

Executive Standard

Cable dc resistance should comply with  GB/T 3956-2008.


3. Operational Performance

    a. Cable conductor allowed long-term working temperature not exceeding 90 ℃.

       When short circuit happened (the duration no longer than 5 seconds), the maximum temperature of cable conductor is not exceeding 250℃.

    b. When laying cable, the ambient temperature should not be lower than 0℃,if not the cable need to be preheated. The bending radius of three cores unarmored cable should not be less than 15 times of outer diameter of cable, 20 times for armored cable.

    c. Cable DC resistance should comply with GB/T 3956-2008.

    d. The laying of cable is not limited by the level drops.

    e. AC voltage withstand test: 3.5kV/5min no breakdown.


4、Cable structure diagram


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:connect sata hard drive to power?
Just connect the power supplies sata power connector to the hard drive. By the way those 4-pin(molex) to sata power connectors are only used if your power supply doesn't have sata power connectors but only molex and your hard drives are sata power. They allow you to connect a 4pin molex to the connector and power sata hard drives with it. If you want to connect a sata power connector to it and get molex power you can't the connector is not designed for that. Also if your hard drive uses sata to connect to the motherboard and has a 4pin power connector just connect a 4pin power cable from the power supply to the hard drive. I hope that answers your question.
Q:power and control cable ... can be installed in seperate parallel conduits?
Yes. That shouldn't be a problem. if it were data or extra low voltage dc then there could be some mutual induction issues. generally speaking. low and extra low voltage can be installed in the same conduit as long as the extra low voltage cables are insulated to the higher voltage present. ie use all cables rated at the highest voltage.
Q:What is the difference between data cables and power cables?
What do you think? Data cables are used to power up the device, and the power cable is used to transfer data.
Q:Is the power supply cable a standard type?
yes they should be interchangable, on the PSU end, the other end (wall) will vay from country to country
Q:Pvc threading tube packaging film how to do attractive, on the grade it? Thank you great god
ZR-KVVRP-500 is mainly used for transmission control, measurement signals and other cables. ZR: Control cable KVVRP: PVC insulation 500: Rated voltage 500 V or less 1 × 2: Two core 1.5: Wire diameter
Q:sony bravia damaged ac power cable?
Change the cable and give the hamster away.
Q:Will my 40 GB PS3 power cable work with my fat PS2?
Google the voltage the PS2 used, and if the PS3's power cable voltage is the same as the PS2's power cable then it's all good. Hope that helps.
Q:Power cable YJV22-8.7 / 15kv-3 * 300 what meaning
Strictly speaking is not in line with the norms. Special signal lines may be subject to interference
Q:My puppy has broken the black plastic on the outside of my laptop power cable, is it dangerous?
no its fine but i would suggest that you take caution in plugging it back in maybe wear rubber gloves or something but you shoould be fine, some people would go out and by a new cord but it is completely unneccesary
Q:what is the standard distance to run cat5 parallel to power cable?
it could be ok at a few inches however i personally had experience where it had to be a few feet but only with power going to a florecent light... whenever light was turned on i lost net yet cat5 could be run right next to light itself or other power lines no problem.. fyi, no one could figure it out, even qwest dsl service people ( 3 in all) - ended up having to be 3 feet from just that certain power line

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range