0.6/1KV,low voltage,XLPE insulated,aluminum conductor,power cable

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
200 m
Supply Capability:
20000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

0.6/1kV XLPE Insulated Power Cable
The cable meets the standard requirements of GB/T12706-2002 or IEC60502-1997.

0.6/1kV XLPE Insulated Power Cable

1.Standards
The cable meets the standard requirements of GB/T12706-2002 or IEC60502-1997. It is suitable to be installed in the power line with rated voltage of 0.6/1kV U0/U (Um).


2.Type, Designation and Applications

TypeDesignationApplicationsYJVYJLVCu or Al conductor XLPE insulated PVC sheathed power cableFor laying indoors, in tunnel and in ducts. Able to bear certain traction during laying but not external mechanical forces. Impermissible to lay single core cable in magnetic ducts.YJV22YJLV22Cu or Al conductor XLPE insulated PVC sheathed internal steel tape armored power cable.For laying indoors, in tunnels, in ducts and underground. Able to bear external mechanical force but not large pulling forces. Impermissible to use single cable in A.C. circuit.

 

3.Specifications

TypeNumber of coresNominal Cross-sectional Area(mm2)YJV YJLV11.0~630YJV YJV22YJLV YJLV2221.0~400YJV YJV22YJLV YJLV2231.0~400YJV YJV22YJLV YJLV223+14.0~400YJV YJV22YJLV YJLV2241.0~400YJV YJV22YJLV YJLV2251.0~400

4.Using properties
1.The maximum rated temperature
The maximum operating temperature of cores shall not exceed 90°C when the cable is used for long period. The temperature of cores shall not exceed 250°C at short circuit for 5 seconds.

2,The installation of cables is not limited by the difference of level along the route. The ambient temperature should not be below 0°C during installation. The permissible bending radius for cable shall not be less than 10 times of the cable diameter. The single cable shall be without amour or with steel wire amour when it is electrified with alternating current and shall not be laid in magnetic ducts.

5.Technical specifications


Rated voltage of cable

0.6/1kV

D.C. resistance of core

According to GB/T3856-1997 or IEC228A-82

Power frequency withstand voltage test for 5 minutes(KV)

No breakdown at 3.5kV

Hot set test for insulation, 200°C 15min with pressure 20N/cm2

Maximum elongation values at load

175%

Maximum permanent elongation values after being cooled

15%

Power frequency withstand voltage test for 4 hours, not break down

2.4


6.Technical parameters
YJV, YJLV 0.6/1kV

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the radiation of the laser scanning scanner?
Semi-conductive shield The semi-conductive shield is usually disposed on the outer surface of the conductive core and the outer surface of the insulating layer, referred to as the inner semiconducting shield and the outer semiconducting shield, respectively The semiconducting shield is made of a semi-conductive material with a low resistivity and a low thickness Internal semiconducting shielding layer is to uniform the outer surface of the electric field, to avoid the conductor surface is not smooth and the core stranded by the air gap caused by the conductor and insulation occurred partial discharge The outer semiconducting shield is in good contact with the outer surface of the insulating layer and is electrically connected with the metal sheath to avoid partial discharge of the metal sheath due to defects such as cable insulation surface cracks For non-metallic jacket in the low-voltage power cable, in addition to the semi-conductive shielding layer, but also to increase the metal shield Metal shield is usually made of copper or copper wire wrapped around the main play the role of shielding the electric field
Q:Computer host configuration of about 1,000 yuan (preferably 1000 below) - probably as follows;
Cable trench as a power construction project should be cable trench construction construction design, cable trench construction program, according to the previous design requirements and programs in order to develop cable trench construction quality acceptance procedures
Q:How to find the phone number on the 110 patch panel
Cable ends should be marked with cable head symbols, the middle line should also be different from the ordinary wiring. Bv at the beginning of the general wire, with YJV or vv is generally a cable, but not limited to these
Q:How to effectively reduce the cost of car wiring harness?
The bottom edge of the bridge after bending (bottom bevel) and the width of the bridge can be the same length, but the range is controlled at 100-400mm, select the length of the two points, in the bridge side to help out on the side Two vertical lines, selected bridge bending direction as the cutting opening side; open the opening side as the bottom edge to draw the two vertical lines were used as two isosceles triangle in the sub-line, the waist triangle Edge length of the formula for the L = 2 × (bridge height × sin22
Q:What is the warranty period for wire and cable?
General cable shelf life is 10 years, look at the jacket and the insulation with or without cracks, shake the insulation resistance of the general do not breakdown can be used, but the best people to do some pressure test. The withstand voltage test must have been used.
Q:Power cable YJV22-8.7 / 15kv-3 * 300 what meaning
(Including the insulation layer) of the total area should not be greater than 40% of the internal cross-section; . the tube wire is not allowed to have joints and twist the phenomenon; . the same loop of the phase of the wire, Regardless of the number of roots should be penetrated into a tube, and different circuits and different voltage lines are not allowed to wear a tube, AC and DC line wires shall not wear a tube, a phase line are not allowed to penetrate alone Steel Pipe. If the requirements are not strict, the power cable, the control cable can wear the same tube; but the signal line will be discretionary, although the signal line is shielded cable, but in order to maximize the signal transmission quality, and other signal lines are generally layout. UPVC plastic pipe with excellent insulation, acid, corrosion resistance, many chemical plants used as infusion piping. The other is also used for sinking engineering, medicine piping works, mineral salt water piping works, electrical piping works. Also widely used as a telecommunications cable. So it can be UPVC pipe to do electrical piping. As for the galvanized steel pipe is not necessary. If the power cable and signal cable at the same time with UPVC pipe laying, were classified separately perforated, the best interval between the two 20cm to prevent interference, with galvanized steel pipe pipe is not necessary so care.
Q:What are the requirements for the spacing between the strong and weak wires?
DIY notebook, I recommend you look at the Jingdong Mall, where there are genuine hardware and equipment, that is just the same as the same to buy back, you have to go home to assemble it! Such as CPU, graphics cards, hard drives, processors, heat sinks, monitors and the like can be bought
Q:The wall was sideways opened a trough how to do ah?
The copper core grinding first to the copper core on the flux (rosin or solder paste)
Q:What is the use of wire and cable per square meter of residential building?
You can use sc. if too long, or bend the best use of the bridge
Q:Ceiling on the wire after the tube is the tube on how to fix it on the ceiling?
That is the two 10KV line is not specifically for you, and perhaps for others.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range