0.6/1kv low smoke zero halogen flame retardant pv cable

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

0.6/1kv low smoke  zero halogen flame retardant pv cable

 

Photovoltaic Cable

 

Introduction of product

 

Our company produces Photovoltaic Cable which is used in advanced radiation cross-linking technology and used low smoke zero halogen flame retardant material produced wires. It has advantages of high temperature resistant, anti oxygen pumping, uv resistance, resistance to water vapor, antimicrobial, short cutting ability, long service life, wear-resisting, oil, anti-corrosion, high tensile resistance, etc.

 

Executive standard

 

The product is according to the standard of TüV 2PfG 1169/08.07.

 

Application

 

The product is suitable for use in extreme weather conditions, indoors and outdoors solar photovoltaic system circuit connection.

 

Operating characteristics

 

U0/U

 

U0/U  0.6/1kV

Operating temperature

 

Max. operating temperature of conductor: 120, Operating ambient temperature: -40℃~90.

 

Type name

 

Type

Name

PV1F

Low smoke zero halogen radiation XLPO insulation low smoke zero halogen radiation XLPO sheath pv cable

 

 

Specification of cable

 

Type

Nom. Cross-Section /mm2

NO.of cores

PV1-F

1.5

1

PV1-F

2.5

1

PV1-F

4

1

PV1-F

6

1

PV1-F

10

1

PV1-F

16

1

PV1-F

25

1

PV1-F

35

1

 

 

 

Structure data of cable

 

Nom. Cross-Section of conductor/mm2

Conductor structure/piece/mm

Conductor diameter/mm

Product diameter/mm

Max direct resistance

(20Ω/km

Referencen weight kg/km

1.5

30/0.25

1.58

5.08

13.7

33.4

2.5

50/0.25

2.04

5.54

8.21

46.2

4

56/0.30

2.59

6.19

5.09

65.8

6

84/0.30

3.4

7.00

3.39

92.4

10

84/0.40

4.5

8.90

1.95

157.4

16

126/0.40

5.55

10.35

1.24

225.8

25

196/0.40

6.92

11.92

0.795

329.4

35

276/0.40

8.7

13.9

0.565

445.1

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Yjv22 cable laying pipe when the casing with plastic or steel pipe
Second, the laying of the bracket, the power cable should be placed in the upper control cable, but 1000 volts below the power cable and control cable can be laid side by side
Q:W22 in the cable on behalf of what
Oh, not W it should be VVVV22 is the meaning of plastic insulated plastic sheath with armored copper cable
Q:What are the requirements for the spacing between the strong and weak wires?
Notebook does not have the opportunity to DIY. The reasons are as follows: Notebook motherboard non-versatile motherboard, the shape of the motherboard, positioning holes, screw holes are not uniform standards, each manufacturer's motherboards are their own engineers and then open factory production model. Notebook shell corresponding to the interface location, type and screw hole location is with a specific motherboard supporting.
Q:20 tons of double beam traffic acceptance standards and content which
Data lines are not original, the proposed replacement, or for a better
Q:Whether the interior decoration is the first brush latex paint or the first installation of the wire (the line, with the trunking)?
The 4.0 square wire refers to the air conditioning power cord single copper core cross-sectional area of 4 square millimeters.
Q:Computer host configuration of about 1,000 yuan (preferably 1000 below) - probably as follows;
Cable trench as a power construction project should be cable trench construction construction design, cable trench construction program, according to the previous design requirements and programs in order to develop cable trench construction quality acceptance procedures
Q:1omoons / days sensitive quad-core network set-top boxes can be used on old-fashioned televisions.
Pipe protection cable to wear metal hose, metal hose and galvanized pipe to use metal lock connection, the connection can not pull the light pull on the line. If there is no metal hose or no metal lock, in the pipe when the pipe toward the cable to the appropriate bending, preferably in the mouth of the cushion cable skin, and then use the electrical adhesive tape sticky, sticky. After the nozzle cut with a polisher smooth grinding, the provincial scratch cable.
Q:How to determine whether the square of the cable is standard
Horizontal laying of the cable within the cable, generally do not need fixed, natural laying can be. Vertical laying section of the cable within the bridge, with the need to match the line card, the use of tied rope (multi-purpose single insulated wire) one by one fixed cable, fixed spacing should meet the requirements. According to the control cable and the power of the different layers of laying, if the power cable to be multi-layer need to have 300mm spacing (or load capacity is large enough), if it is control cable, casually laying, if the laying of power cable laying below Layer, above the laying of control cable, but not too much affect the power cable cooling. If the high-voltage cable and low-voltage cable in principle do not allow common laying.
Q:3 (WDZBN-YJV-4x240 + 1x120) cable how to interpret
3 (WDZBN-YJV-4x240 + 1x120) cable is a low smoke halogen-free flame retardant (B grade) XLPE insulated - PE sheathed copper core power cable. The model of the cable is usually composed of eight parts: First, the use of code - not marked as the power cable, K for the control cable, P for the signal cable; so the power cable. Second, the insulation code -Z oil-impregnated paper, X rubber, V polyvinyl chloride, YJ cross-linked polyethylene; so for the cross-linked polyethylene insulation. Third, the conductor material code - not marked as copper, L is aluminum; therefore copper. Four, inner layer code-Q lead package, L aluminum bag, H rubber sleeve, V PVC jacket; so for the PVC jacket. . derived code-D no drip, P dry insulation. Sixth, the outer layer code. . special product code-TH wet tropical, TA dry tropical, ZR- (flame retardant), NH- (fire), WDZ- (low smoke zero halogen, enterprise standards); so low smoke halogen-free flame retardant The . rated voltage - unit KV; general cable are marked, the problem is estimated to write missing 0.6 / . the use of: rated phase voltage of 0.6KV, line voltage of 1KV. In the cable, 4 * 240 + 1 * 120 that there are 4 core 240 square copper wire, a 1-core 120 square copper wire.
Q:Emergency power off after the computer can not open the machine, an open is a lot of words appear seconds limit, you can
There is a collection of. There is a direct connection, there are T then. Electric well trunking without cover, how can be connected

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range